58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Beckman Coulter MoFlo Astrios EQS 4-Laser Flow Cytometer Cell Sorter Integrated in SterilGARD BSC

Price on request

In stock

Can't find what you're looking for?

Description
Model: MoFlo Astrios EQS. Serial No.: BB36225. Manufactured: 2018. Integrated into a Baker Company SterilGARD BSC model SG503HE-BC, serial 126164, manufactured 06/04/18. Voltage: 100-230 V. Frequency: 50-60 Hz. Power consumption: 805 W. Current: 8.0 A. Fuse rating: N/A. Software version: N/A. Configuration includes 4 lasers at 405 nm, 488 nm, 561 nm, and 640 nm wavelengths. The system is equipped with multiple optical detectors and sorting modules. The package includes a dedicated PC workstation and a Jun-Air OF302-25MQ2 air compressor (serial 1117801672, manufactured 2017) for pneumatic support.
Technical Data
Model: MoFlo Astrios EQS Serial Number: BB36225 Voltage: 100-230 V Frequency: 50-60 Hz Power Consumption: 805 W Fuse Rating: N/A Software Version: N/A Configuration: 4 lasers (405 nm, 488 nm, 561 nm, 640 nm), integrated into Baker SterilGARD BSC SG503HE-BC, includes optical detector modules, sorting modules, dedicated PC workstation, Jun-Air OF302-25MQ2 air compressor Manufacturing Year: 2018
Voltage
100-230 V
Frequency
50-60 Hz
Power Consumption
805 W
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Beckman Coulter
New/Used
Used
Description
Model: MoFlo Astrios EQS. Serial No.: BB36225. Manufactured: 2018. Integrated into a Baker Company SterilGARD BSC model SG503HE-BC, serial 126164, manufactured 06/04/18. Voltage: 100-230 V. Frequency: 50-60 Hz. Power consumption: 805 W. Current: 8.0 A. Fuse rating: N/A. Software version: N/A. Configuration includes 4 lasers at 405 nm, 488 nm, 561 nm, and 640 nm wavelengths. The system is equipped with multiple optical detectors and sorting modules. The package includes a dedicated PC workstation and a Jun-Air OF302-25MQ2 air compressor (serial 1117801672, manufactured 2017) for pneumatic support.
Technical Data
Model: MoFlo Astrios EQS Serial Number: BB36225 Voltage: 100-230 V Frequency: 50-60 Hz Power Consumption: 805 W Fuse Rating: N/A Software Version: N/A Configuration: 4 lasers (405 nm, 488 nm, 561 nm, 640 nm), integrated into Baker SterilGARD BSC SG503HE-BC, includes optical detector modules, sorting modules, dedicated PC workstation, Jun-Air OF302-25MQ2 air compressor Manufacturing Year: 2018
Voltage
100-230 V
Frequency
50-60 Hz
Power Consumption
805 W
Fuse Rating
N/A
Software Version
N/A
Configuration
4 lasers (405 nm, 488 nm, 561 nm, 640 nm), integrated into Baker SterilGARD BSC SG503HE-BC, includes optical detector modules, sorting modules, dedicated PC workstation, Jun-Air OF302-25MQ2 air compressor
Manufacturing Year
2018
Accessories
Dedicated PC workstation, Jun-Air OF302-25MQ2 air compressor, Multiple optical detector modules, Sorting modules, Laser safety signage, Various cables and connectors, User manuals and software CDs, Spare parts kit, Fluidics and tubing kits
Dimensions
SterilGARD BSC approx. 72 x 38 x 78 inches (HxWxD) including flow cytometer
Weight
N/A

Product description

High-performance 4-laser MoFlo Astrios EQS flow cytometer cell sorter integrated in SterilGARD BSC for sterile multi-parameter cell analysis.

The Beckman Coulter MoFlo Astrios EQS is an advanced 4-laser flow cytometer cell sorter designed for precision multi-parameter cell analysis and sorting within a sterile environment. Integrated into a Baker SterilGARD SG503HE-BC biosafety cabinet, this system provides high sorting purity and sensitivity crucial for applications in molecular diagnostics, synthetic biology, and bioprocessing workflows.

Key technical features include:

  • Four laser wavelengths at 405 nm, 488 nm, 561 nm, and 640 nm for extensive fluorochrome compatibility and complex fluorescence analysis.
  • Multiple optical detector modules and sorting modules enabling precise discrimination and isolation of cell populations.
  • Dedicated PC workstation with integrated software control to facilitate detailed data acquisition and sorting protocols.
  • Pneumatic support via the Jun-Air OF302-25MQ2 air compressor ensures consistent fluidics stability for efficient cell sorting operations.
  • Electrical specifications: 100–230 V, 50–60 Hz, 805 W power consumption ensuring compatibility with diverse laboratory infrastructures.
  • The entire setup measures approximately 72 x 38 x 78 inches (HxWxD) including the biosafety cabinet, optimized for space within sterile biotechnology laboratories.

This flow cytometer sorter system is widely used in live-cell analysis, biomanufacturing pipelines, and gene editing research, essential for laboratories seeking reliable cell sorting in a biosafe environment. The integration with the SterilGARD biosafety cabinet emphasizes aerosol containment and operator safety, making it critical for clinical diagnostics and biomedical engineering applications. This setup supports complex single-cell workflows, making it an indispensable tool for cell imaging, fluorescence analysis, and neuroscience research where high sensitivity and sterile processing are paramount.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026