Capacity
23 cu. ft. (651.3L)
Temperature Setpoint Range
4°C to 70°C
Temperature Control
± 0.1°C
Temperature Stability
± 0.5°C
Temperature Uniformity
± 1°C
All 16 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 16

Brands
Corepoint Scientific
New/Used
New
Capacity
23 cu. ft. (651.3L)
Temperature Setpoint Range
4°C to 70°C
Temperature Control
± 0.1°C
Temperature Stability
± 0.5°C
Temperature Uniformity
± 1°C
Humidity Setpoint Range
15 to 95% RH
Humidity Control
± 0.1% RH
Humidity Stability
± 3% RH
Refrigerant
R600a
Water Supply Required
10 to 60 PSI demineralized water
External Dimensions (W x D x H)
26.86 x 36.38 x 80.8 in.
Internal Dimensions (W x D x H)
22 x 25.5 x 59 in.
Weight
380 lb. (172.4 kg)
Electrical Requirements
115V, 60Hz, 12.4A

Product description

High-performance stability chamber for precise control of temperature and humidity in laboratory settings.

Corepoint Scientific NSRI231WSW-0H Single Solid Door Temperature and Humidity Stability Chamber

Temperature Setpoint Range 4°C to 70°C Humidity Setpoint Range 15 to 95% RH Capacity 23 cu. ft. (651.3L)

Features

  • Engineered for stringent scientific and laboratory research requirements
  • Advanced design in cabinet construction, refrigeration, temperature control, and monitoring
  • One right-hinged, self-closing solid door and three 304 stainless steel sliding tray shelves
  • PID controller with LCD display, programmable ramp and soak functions, and USB data port
  • Foamed-in-place polyurethane foam insulation and white powder-coated steel exterior
  • Top-mounted variable speed compressor and hydrocarbon natural refrigerant (R600a)
  • Ultrasonic humidification and multi-element proportional electric heating
  • Heavy-duty door handle, magnetic door gasket, keyed door lock, and probe access port

The Corepoint Scientific NSRI231WSW-0H Single Solid Door Temperature and Humidity Stability Chamber is engineered to meet the stringent requirements of scientific and laboratory research. This chamber features advanced design elements in cabinet construction, refrigeration, temperature control, and monitoring, ensuring energy-efficient, safe, and reliable performance for optimal storage environments. It includes one right-hinged, self-closing solid door and three 304 stainless steel sliding tray shelves. The PID controller with an LCD display offers programmable ramp and soak functions, process phase graphic animations, a USB data port, RS-485 communication (MODBUS-RTU), real-time clock, battery backup, and event logs. The chamber provides precise temperature control (4°C to 70°C) with ± 0.1°C accuracy and uniformity of ± 1°C. Humidity control ranges from 15 to 95% RH with ± 0.1%RH accuracy and stability of ± 3% RH. Additional features include foamed-in-place polyurethane foam insulation, a white powder-coated steel exterior, a 304 stainless steel interior, plenum air distribution, a floor drain, top-mounted variable speed compressor, hydrocarbon natural refrigerant (R600a), ultrasonic humidification, multi-element proportional electric heating, and shielded interior LED lighting. The chamber also includes a heavy-duty door handle, magnetic door gasket, keyed door lock, and a probe access port.

INCLUDED: The Corepoint Scientific NSRI231WSW-0H Single Solid Door Temperature and Humidity Stability Chamber includes:

  • Key for Door Lock
  • 3 x Sliding Shelves
  • Power Cord
  • Operator's Manual
  • 18 Month Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 23 October 2026