54k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Spark Holland Triathlon 900 HPLC Autosampler

From€2,750excl. VAT

In stock

Can't find what you're looking for?

Volume Range
1 to 1000 µL
All 4 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 4

Dimensions
55 × 30 × 44
Brands
Spark Holland
New/Used
Used
Volume Range
1 to 1000 µL

Product description

Spark Holland Triathlon 900 HPLC autosampler for chromatography with three injection methods, 1 µL to 1 mL volumes, and vial holders.

The Spark Holland Triathlon 900 autosampler is an HPLC autosampler for chromatography and analytical sample handling in biotechnology laboratories.

The autosampler provides Flushed Loop, Partial Loopfill and µL Pick-up injection methods. Flushed Loop fills the sample loop completely for reproducible injections. Partial Loopfill supports programmable injection volumes with low sample loss. µL Pick-up transports the sample into the loop with mobile phase and avoids sample loss. Segment holders support either 96 vials of 1.5 mL or 32 vials of 10.0 mL.

This used unit is inspected and tested before sale. It is delivered only when it functions properly.

The Spark Holland Triathlon 900 is an HPLC autosampler for liquid chromatography applications.

  • Injection methods: Flushed Loop, Partial Loopfill and µL Pick-up
  • Injection volume: 1 µL to 1 mL
  • Adjustment increment: 1 µL
  • Analysis time: Up to 10 hours
  • Vial capacity options:
  • 96 vials of 1.5 mL, arranged as 12 vials per segment across 8 segments
  • 32 vials of 10.0 mL, arranged as 4 vials per segment across 8 segments

A syringe draws the sample from a vial into the sample loop. Buffer tubing between the syringe and injection valve helps prevent contamination. Wash solvent removes sample from the buffer tubing and sample needle.

This used autosampler was inspected and tested before sale and is delivered only when functioning properly.

What these specifications mean

The three injection methods address different sample handling requirements. Flushed Loop supports reproducible injections through complete loop filling. Partial Loopfill reduces sample loss when the method requires programmable injection volumes. µL Pick-up transfers the sample with mobile phase and avoids sample loss.

The 1 µL to 1 mL injection range, adjustable in 1 µL increments, supports method-specific dosing across small and larger HPLC injection volumes. Analysis runs can last up to 10 hours.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 29 November 2026