56k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

IKA C 6000 Automated Calorimeter Global Standards Package 2/12

NewIKACalorimetersUnited States

From€39,701.16excl. VAT

In stock

Can't find what you're looking for?

Measuring Range Max.
40000 J
Measuring Mode Adiabatic 22°C
Yes
Measuring Mode Dynamic 22°C
Yes
Measuring Mode Isoperibol 22°C
Yes
Measuring Mode Adiabatic 25°C
Yes
All 52 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 52

Brands
IKA
New/Used
New
Measuring Range Max.
40000 J
Measuring Mode Adiabatic 22°C
Yes
Measuring Mode Dynamic 22°C
Yes
Measuring Mode Isoperibol 22°C
Yes
Measuring Mode Adiabatic 25°C
Yes
Measuring Mode Dynamic 25°C
Yes
Measuring Mode Isoperibol 25°C
Yes
Measuring Mode Adiabatic 30°C
Yes
Measuring Mode Dynamic 30°C
Yes
Measuring Mode Isoperibol 30°C
Yes
Measurements per Hour Adiabatic
5
Measurements per Hour Dynamic
6
Measurements per Hour Isoperibol
4
Reproducibility Adiabatic (1g Benzoic Acid NBS39i)
0.05% RSD
Reproducibility Dynamic (1g Benzoic Acid NBS39i)
0.15% RSD
Reproducibility Isoperibol (1g Benzoic Acid NBS39i)
0.05% RSD
Touchscreen
Yes
Working Temperature
22 to 30 °C
Temperature Measurement Resolution
0.0001 K
Cooling Medium Temperature
12 to 27 °C
Cooling Medium Permissible Operating Pressure
1.5 Bar
Cooling Medium
Tap Water
Type of Cooling
Flow
Flow Rate
60 to 70 L/H
Rec. Flow Rate at 18°C
60 L/H
Oxygen Operating Pressure Max.
40 Bar
Interface Scale
RS232
Interface Printer
USB
Interface PC
RS232
Interface Test Rack
Yes
Interface Ext. Keyboard
Yes
Oxygen Filling
Yes
Degasification
Yes
Decomposition Detection
Yes
Decomposition Vessel C 6012
Yes
Decomposition Vessel, Halogen Resistant
Yes
Analysis According to DIN 51900
Yes
Analysis According to ASTM D240
Yes
Analysis According to ASTM D4809
Yes
Analysis According to ASTM D5865
Yes
Analysis According to ISO 1928
Yes
Analysis According to GB T213
Yes
Dimensions (W x H x D)
19.7 x 16.7 x 17.7 in. (50 x 42.5 x 45 cm)
Weight
88.5 lb. (40.14 kg)
Permissible Ambient Temperature
20 to 30 °C
Permissible Relative Humidity
80 %
Protection Class According to DIN EN 60529
IP 20
RS 232 Interface
Yes
USB Interface
USB-B
Electrical Requirements
100 to 120 V 50/60 Hz, 1700 W

Product description

Precision calorimeter with enhanced automation, ideal for sulfur and halogen analysis.

IKA C 6000 Automated Calorimeter Global Standards Package 2/12

Measuring Range Max. 40000 J Reproducibility Dynamic (1g Benzoic Acid NBS39i) 0.15% Reproducibility Isoperibol (1g Benzoic Acid NBS39i) 0.05%

Features

  • Automatic ignition and ignition determination
  • Automatic water filling and draining
  • Automatic oxygen filling, venting and flushing
  • RFID technology for automatic decomposition vessel identification
  • New design of the decomposition vessel allowing easier and faster sample preparation
  • Easy and convenient capacitive touch screen operation
  • Control chart view and correction calculation of globally used standards
  • Ethernet interface to connect a network printer
  • USB interface allowing easy data management and software updates
  • This Package 2/12 includes a halogen resistant decomposition vessel C 6012 with catalytically active surface leading to higher recovery rates on halogens and sulfur

The IKA C 6000 Automated Calorimeter Global Standards Package 2/12 sets a new benchmark in precision and efficiency for modern calorimetry. This advanced system operates seamlessly across adiabatic, isoperibolic, and dynamic measuring modes, offering flexibility to suit diverse laboratory requirements. Users can select from three starting temperatures (22°C, 25°C, 30°C) to optimize measurements, all while adhering to globally recognized standards such as DIN, ISO, ASTM, and GB. Featuring a redesigned decomposition vessel, this package enhances sample preparation efficiency and recovery rates for halogens and sulfur, thanks to its catalytically active, halogen-resistant surface. Please note that while this system is compatible with the RC 2 Basic Chiller for optimal cooling performance, the chiller is not included with this package.

Streamlined automation defines the C 6000, incorporating automatic ignition, oxygen filling, and water handling for effortless operation. The capacitive touchscreen ensures intuitive navigation, while the built-in RFID technology provides automatic identification of decomposition vessels for enhanced accuracy. With robust data management capabilities via Ethernet, USB, and RS232 interfaces, this calorimeter simplifies integration into existing workflows and supports comprehensive analysis. The included control chart view and correction calculation features further reinforce compliance with globally applied standards.

This Package 2/12 includes the halogen-resistant decomposition vessel C 6012, making it ideal for laboratories demanding high precision in sulfur and halogen analysis. Compact and efficient, with dimensions of 19.7 x 16.7 x 17.7 inches and a weight of 88.5 lbs, the IKA C 6000 ensures optimal performance within a permissible temperature range of 20°C to 30°C. Whether for research, industrial, or quality control applications, this package delivers the reliability and adaptability necessary for advanced calorimetry.

INCLUDED: The IKA C 6000 Automated Calorimeter Global Standards Package 2/12 includes:

  • C 6012 Decomposition Vessel, Halogen Resistant
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 29 October 2026