56k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling

NewIKACalorimetersUnited States

From€24,784.09excl. VAT

In stock

Can't find what you're looking for?

Measuring Range Max.
40000 J
Measuring Mode Dynamic 25°C
Yes
Measuring Mode Isoperibol 25°C
Yes
Measuring Time Dynamic Approx.
8 Min
Measuring Time Isoperibol Approx.
17 Min
All 40 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 40

Brands
IKA
New/Used
New
Measuring Range Max.
40000 J
Measuring Mode Dynamic 25°C
Yes
Measuring Mode Isoperibol 25°C
Yes
Measuring Time Dynamic Approx.
8 Min
Measuring Time Isoperibol Approx.
17 Min
Reproducibility Dynamic (1g Benzoic Acid NBS39i)
0.1% RSD
Reproducibility Isoperibol (1g Benzoic Acid NBS39i)
0.1% RSD
Working Temperature Max.
25 °C
Temperature Measurement Resolution
0.0001 K
Cooling Medium Permissible Operating Pressure
2 Bar
Cooling Medium
Tap Water
Type of Cooling
Flow
Chiller
RC 2 Basic
Rec. Flow Rate at 18°C
60 L/H
Oxygen Operating Pressure Max.
40 Bar
Interface Printer
Centronix
Interface PC
RS232
Decomposition Vessel C 5010
Yes
Works According to DIN 51900
Yes
Works According to DIN EN ISO 1716
Yes
Works According to DIN EN ISO 18125
Yes
Works According to DIN EN 15400
Yes
Works According to DIN CEN TS 14918
Yes
Works According to DIN CEN/TS 16023
Yes
Works According to DIN SPEC 19524
Yes
Works According to ASTM D240
Yes
Works According to ASTM D4809
Yes
Works According to ASTM D5468
Yes
Works According to ASTM D5865
Yes
Works According to ISO 1928
Yes
Works According to GOST Certified
Yes
Permissible Ambient Temperature
20 to 25°C
Permissible Relative Humidity
80 %
Protection Class According to DIN EN 60529
IP 20
RS 232 Interface
Yes
Dimensions (W x H x D)
15.7 x 15.7 x 15.7 in. (40 x 40 x 40 cm)
Weight
46.3 lb. (21 kg)
Electrical Requirements
100 to 240 V 50/60 Hz, 120 W

Product description

Compact and efficient calorimeter with automated water handling for precise calorific measurements.

IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling

Measuring Range Max. 40000 J Measuring Time Dynamic Approx. 8 min Cooling Medium Permissable Operating Pressure 2 bar

Features

  • Compact, space-saving, and cost-effective design for educational and low-volume industrial laboratories
  • Capable of measuring calorific values for liquid and solid samples
  • Four operation modes: isoperibol, dynamic, manual, and time-controlled (14 min).
  • Semi-automated system with manual water and oxygen handling, and optional automation available
  • Closed-loop water circulation with optional RC 2 basic chiller for improved reproducibility and efficiency
  • Operated via C 6040 CalWin software for monitoring, multi-calorimeter management, and data export
  • Compatible with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711, GOST 147, GOST 21261
  • Compact dimensions (15.7 x 15.7 x 15.7 in.) and lightweight (46.3 lb.) for ease of installation
  • Installation and calibration consumables included for seamless setup

The C 200 auto package allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results.

The semi-automated and conforming to standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses.

Four different operation modes enable the user to control the measuring times according to individual requirements: Isoperibol: approx: 17 min. Dynamic : approx. 8 min Manual : approx. 17 min (depends on the operator) Time controlled : 14 min

Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.

The software C 6040 Calwin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. Calwin is sold separately.

INCLUDED: The IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling includes:

  • C 200 Measuring Cell
  • C 5010 Decomposition Vessel
  • C 248 Oxygen Filling Station
  • RC 2 Basic Recirculating Chiller
  • Ignation Adapter
  • Water Emptying Hose
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 29 October 2026