Product description

Calibrate pipettes precisely with the Radwag XA100 using gravimetric methods.

XA100 pipette calibration adapter enables calibration and/or verification of piston pipettes by means of a gravimetric method using the XA analytical balence.

Set content:

base

weighing pan

weighing vessel

evaporation ring

glass chamber with an opening for dosing

Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts.

Vessel capacity: 100 ml

Adapters for Pipettes Calibration

Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object.

Nominal volume of apparatus under test V

Resolution (d) mg

Repeatability (s)3mg

Recommended balance

Microbalances

Analytical balances

0,5 µl ≤ V < 20 µl

0,001c 0,01d

0,006c, e 0,03d

MYA 21.5Y

XA 6/21.5Y.M.A

XA 6/21.5Y.M

XA 21.5Y.M.A

XA 21.5Y.M

XA 21/52.5Y.M.A

XA 21/52.5Y.M

XA 53.5Y.M.A

XA 53.5Y.M

20 µl ≤ V < 200 µl

0,01

0,025

XA 52.5Y

XA 110.5Y

XA 82/220.5Y.A

XA 82/220.5Y

XA 120/250.5Y.A

XA 120/250.5Y

200 µl ≤ V ≤ 10 ml

0,1

0,2

Adapter for pipette calibration

MY 11

XA 11

XA 11

XA 11

XA 11

XA 17

XA 17

XA 17

XA 100

XA 17

XA 100

Maximum vessel capacity

11 ml

11 ml

11 ml

11 ml

11 ml

17 ml

17 ml

17 ml

100 ml

17 ml

100 ml

Weighing vessel mass

~ 10 g

~ 10 g

~ 10 g

~ 10 g

~ 10 g

~ 11 g

~ 11 g

~ 11 g

~ 65 g

~ 11 g

~ 65 g

a

The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c

Single-channel balance. d

Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e

For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object.

table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026