53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Ohaus MB62 Moisture Analyzer with Carbon Fiber Heating and 5" LCD Display

From€4,652excl. VAT

In stock

Can't find what you're looking for?

Maximum Capacity
90 g
Readability Moisture Content
1 mg/0.01%
Pan Size (Ø_Diameter)
90 mm (3.5 in)
Heater Type
Carbon fiber
Dimensions (Length)
352 mm (13.9 in)
All 33 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 33

Brands
Ohaus
New/Used
Used
Maximum Capacity
90 g
Readability Moisture Content
1 mg/0.01%
Pan Size (Ø_Diameter)
90 mm (3.5 in)
Heater Type
Carbon fiber
Dimensions (Length)
352 mm (13.9 in)
Dimensions (Width)
210 mm (8.3 in)
Dimensions (Height)
138 mm (5.4 in)
Adjustment
Temperature Adjustment - Mechanical (100℃, 160℃);Weight Adjustment - External (50g)
Communication
USB device;RS232
Display
5" LCD with 2nd line display
Display Results
RG%;Temperature;DC%;Time;Method No.;MC%;Weight
Heating Profiles
Ramp;Standard;Step;Fast
ID Management
Sample ID
Inuse cover
Included
Minimum Start Weight
0.5 g
Moisture Range
0.01 % – 100 %
Net Weight
4.3 kg (9.5 lb)
Operating Range (Temp.)
10 °C – 40 °C
Operation Instructions
Graphic Instruction;On-screen Instruction;Progress Indicator
Recommended Moisture Content MC%
0.5 % - 100 %
Repeatability
0.018% (10g sample);0.10% (3g sample)
Shut-Off Criteria
Timed;5 Auto;Manual
Status Light
Multi-color status light
Stored Results
100
Tare Range
To capacity by subtraction
Temperature Range
40 °C – 200 °C
Test Library
20
Test Weight
50g, OIML F2 or ASTM CL 4
Main Purpose
Moisture Analysis
Market Worlds
Industrial;Education;Pharmacy;Laboratory;Food
Typical Areas
In food processing and preparation environments;In a wastewater treatment plant;In a classroom;In a laboratory;In a light industrial enviroment;In a pharmacy school;In a contract laboratory;In an industrial environment;In pharmaceutical production

Product description

Moisture analyzer with 90g capacity, carbon fiber heater, 5" LCD, RS232/USB, 20 method storage, 100 result memory.

Ohaus MB62 Moisture Analyzer Model #30971929

  • Capacity: 90 g maximum
  • Moisture Content Readability: 1 mg / 0.01%
  • Pan Size: 90 mm (3.5 in) diameter
  • Heating Source: Carbon fiber heating technology
  • Display: 5-inch LCD with secondary line display
  • Dimensions: 352 mm (L) x 210 mm (W) x 138 mm (H)
  • Weight: 4.3 kg (9.5 lb)
  • Temperature Range: 40 °C to 200 °C
  • Operating Temperature Range: 10 °C to 40 °C
  • Adjustments:
  • Temperature adjustable mechanically between 100 °C and 160 °C
  • External weight adjustment of 50 g
  • Communication Interfaces: USB device and RS232 port
  • Display Parameters: Regain %, Temperature, Dry Content %, Time, Method Number, Moisture Content %, Weight
  • Heating Profiles: Ramp, Standard, Step, Fast
  • Sample and Method Management:
  • Stores up to 20 drying methods
  • Stores 100 test results with Sample ID (up to 10 IDs)
  • Features:
  • Seven shut-off criteria: manual, timed, and six auto criteria (A10, A30, A60, A90, A160)
  • Multi-color status light indicating machine and test status
  • Graphical on-screen instruction and progress indicator
  • In-use cover included
  • Minimum Start Weight: 0.5 g
  • Moisture Range: 0.01 % to 100 %
  • Repeatability: 0.018% for 10 g samples; 0.10% for 3 g samples
  • Tare Range: To full capacity by subtraction
  • Compliance Weights: 50 g, OIML F2 or ASTM CL 4 standard
  • Intended Application Areas: Industrial, Education, Pharmacy, Food, Laboratory settings including food processing, wastewater treatment, pharmaceutical production, light industrial and contract laboratories.

The MB62 is designed for reliable, precise moisture determination with enhanced durability through carbon fiber heating and robust construction, suitable for diverse laboratory and industrial moisture analysis tasks.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 2 November 2026