58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Eppendorf Research Plus 3 Pipette Kit, 0.5 to 1000uL

NewEppendorfPipettesUnited States

€997.03excl. VAT

In stock

Can't find what you're looking for?

Adjustable or Fixed Volume
Adjustable Volume
Pipette Type
Air Displacement
Pipette Volumes
0.5 to 10 uL (adjustable in 0.01 uL increments) 10 to 100 uL (adjustable in 0.1 uL increments) 100 to 1000 uL (adjutable in 1 uL increments)
Maximum Systematic Error
0.5 to 10 uL: ± 8% (± 0.1 uL) 10 to 100 uL: ± 3% (± 0.5 uL) 100 to 1000 uL: ± 3% (± 6 uL)
Maximum Random Error
0.5 to 10 uL: ± 5% (± 0.04 uL) 10 to 100 uL: ± 1% (± 0.15 uL) 100 to 1000 uL: ± 0.6% (± 2 uL)
All 8 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 8

Brands
Eppendorf
New/Used
New
Adjustable or Fixed Volume
Adjustable Volume
Pipette Type
Air Displacement
Pipette Volumes
0.5 to 10 uL (adjustable in 0.01 uL increments) 10 to 100 uL (adjustable in 0.1 uL increments) 100 to 1000 uL (adjutable in 1 uL increments)
Maximum Systematic Error
0.5 to 10 uL: ± 8% (± 0.1 uL) 10 to 100 uL: ± 3% (± 0.5 uL) 100 to 1000 uL: ± 3% (± 6 uL)
Maximum Random Error
0.5 to 10 uL: ± 5% (± 0.04 uL) 10 to 100 uL: ± 1% (± 0.15 uL) 100 to 1000 uL: ± 0.6% (± 2 uL)
Pipette Series
Research Plus

Product description

Ergonomic, lightweight pipette kit for precise, adjustable volume pipetting.

Eppendorf Research Plus 3 Pipette Kit, 0.5 to 1000uL

Adjustable or Fixed Volume Adjustable Volume Range 0.5 to 1000uL Pipette Type Air Displacement

Features

  • Mechanical air-cushion pipette with standard 3-button operation (one operating element for volume selection, one for pipetting, and one for tip ejection)
  • Ideal for accurate, easy, and ergonomic manual pipetting of aqueous solutions
  • Feel the difference in weight and pipetting forces: Designed according to the Eppendorf PhysioCare Concept® principles
  • Benefit from one of the lowest operating and tip ejection forces on the pipette market, helping to reduce hand and arm strain
  • Enjoy minimal tip attachment forces due to a spring-loaded tip cone (available for all pipettes up to 1 mL)
  • Temporarily adjust your pipette in seconds for better accuracy when pipetting challenging liquids like ethanol or when pipetting at high altitudes. Return to factory adjustment without calibration
  • Autoclave the entire pipette or only the lower part according to your needs and applications to ensure a proper decontamination
  • Premium material ensures a high UV and chemical resistance; special single-channel lower parts for aggressive chemicals available
  • ACT®-labeled single-channel pipettes and epT.I.P.S.® pipette tips help you make an informed choice when it comes to sustainability

The Eppendorf Research Plus 3 Pipette Kit offers an ergonomic and lightweight solution for precise manual pipetting. This kit features a mechanical air-cushion design with a standard 3-button operation, facilitating volume selection, pipetting, and tip ejection. It is engineered to minimize strain with one of the lowest operating and tip ejection forces available, thanks to its compliance with the Eppendorf PhysioCare Concept®. The spring-loaded tip cone ensures minimal attachment forces for pipettes up to 1 mL, enhancing user comfort. Adjust the pipette quickly for specific needs like pipetting challenging liquids or working at different altitudes, with an easy return to factory settings without recalibration.

Each component, from the pipette to the lower part, can be autoclaved for thorough decontamination. Made with premium materials, these pipettes offer high UV and chemical resistance, and they are available with single-channel lower parts designed for aggressive chemicals. The ACT® label on single-channel pipettes and epT.I.P.S.® pipette tips highlights their eco-friendly attributes. These durable, intuitive pipettes feature 4-digit displays and color coding for easy selection, providing a dependable and sustainable option for daily laboratory tasks.

INCLUDED: The Eppendorf Research Plus 3 Pipette Kit, 0.5 to 1000ul includes:

  • 3 Single-Channel Pipettes (0.5 - 10 uL, 10 - 100 uL, and 100 - 1000 uL)
  • 3 x epT.I.P.S Pipette Tips Boxes (x 96 tips, 20 uL M, 200 uL, 1000 uL)
  • Operator's Manual
  • Manufacturer's Documentation
  • 6 Month Full Parts and Labor Warranty

Eppendorf Research Plus 3 Pipette Kit, 0.5 to 1000uL SpecificationsAdjustable or Fixed VolumeAdjustable VolumePipette TypeAir DisplacementPipette Volumes0.5 to 10 uL (adjustable in 0.01 uL increments)10 to 100 uL (adjustable in 0.1 uL increments)100 to 1000 uL (adjutable in 1 uL increments)Maximum Systematic Error0.5 to 10 uL: ± 8% (± 0.1 uL)10 to 100 uL: ± 3% (± 0.5 uL)100 to 1000 uL: ± 3% (± 6 uL)Maximum Random Error0.5 to 10 uL: ± 5% (± 0.04 uL)10 to 100 uL: ± 1% (± 0.15 uL)100 to 1000 uL: ± 0.6% (± 2 uL)Pipette SeriesResearch PlusDownloadsTechnical Specification Download Operator's Manual Download

Request a Formal Quote .features-side img{height:500px;}

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026