GLP Features
Early maintainece feedback (EMF), electronic records of maintainence and errors
Communications
Controller-area network (CAN). RS232C, APG remote standard, optional four external contact closures and BCD vial number output
Safety Features
Leak detection and safe leak handling, low voltages in maintence areas, error detection and display
Injection Range
0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
Precision
Typically < 0.25 % RSD from 5 – 100 µl, Typically < 1 % RSD from 1 – 5 µl
Availability
Sold
All 12 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 12

Brands
Agilent
New/Used
Used
GLP Features
Early maintainece feedback (EMF), electronic records of maintainence and errors
Communications
Controller-area network (CAN). RS232C, APG remote standard, optional four external contact closures and BCD vial number output
Safety Features
Leak detection and safe leak handling, low voltages in maintence areas, error detection and display
Injection Range
0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
Precision
Typically < 0.25 % RSD from 5 – 100 µl, Typically < 1 % RSD from 1 – 5 µl
Pressure Range
400 bar (5800 psi)
Sample Viscosity Range
0.2 – 5 cp
Sample Capacity
2 × well-plates (MTP) + 10 × 2 ml vials 108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate
Injection Cycle Time
Typically < 30 s using following standard conditions: Default draw speed: 200 µl/min Default eject speed: 200 µl/min Injection volume: 5 µl
Carry-Over
Typically < 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: Water/Acetonitrile = 80/20 Flow rate: 1 ml/min Injection volume: 1 µl caffeine (1 mg/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port

Product description

Autosampler for Agilent 1200 HPLC with 0.1–100 µl injection range and <0.25% RSD precision.

The Agilent 1200 HPLC G1367B High Performance Autosampler provides precise and fast sample injection for HPLC systems.

  • Injection Range: 0.1 – 100 µl in 0.1 µl increments
  • Precision:
  • Typically < 0.25 % RSD for 5 – 100 µl
  • Typically < 1 % RSD for 1 – 5 µl
  • Pressure Range: 400 bar (5800 psi)
  • Features:
  • Overlapped injections reduce cycle times, increasing productivity
  • Minimal delay volumes support rapid gradients and fast system equilibration
  • Flexible sample handling with compatibility for well plates, vials, and Eppendorf tubes
  • Advanced GLP features: early maintenance feedback (EMF), electronic maintenance and error records
  • Multiple communication interfaces: CAN, RS232C, APG remote, optional external contact closures
  • Safety: leak detection, safe leak handling, low maintenance voltages
  • Injection cycle time under 30 seconds optimized for high-throughput workflows
  • Carry-over typically less than 0.01% ensuring cleaner results

The G1367B autosampler is designed for laboratories requiring high sample throughput and rapid analysis with maximum reliability and precise volume control.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 23 November 2026