Circulation Method
Forced air circulation
Operating Temp. Range
Room temp. +10°C~210°C
Temp. Adjustment Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
60 min
Availability
Sold
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
Operating Temp. Range
Room temp. +10°C~210°C
Temp. Adjustment Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
60 min
Interior/Exterior Material
Stainless steel / Cold rolled steel plate with melamine resin baking finish
Heat Insulating Material
Glass wool
Heater
SUS pipe heater/1.8kWx2
Fan Type / Fan Motor
2pc / 10W
Cable Hole
30mm I.D. (on the right side) 1pc.
Exhaust Port
30mm I.D.×2 (the back)
Temp. Controller
3 patterns program controller, PID control by microprocessor
Temp. Setting Method
Digital setting by ▲/▼ key
Temp. Display
Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. with timer wait function
Operation Function
Fixed temperature operation, Program operation, Auto start, Auto stop, Quick Auto-stop
Program Mode
Program operation : 3 patterns, 30 steps (30 steps×1, 15 steps×2, 10 steps×3) Pattern repeat function
Additional Functions
Calibration off-set function, Key lock, Uninterruptible power for memory
Heater Circuit Control
SSR control
Sensor
K-thermocouple
Safety Device
Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Automatic overheating prevention), Key lock function, Overheat prevention, Electric leakage breaker with over current protection
Internal Dimensions W×D×H
1070×500×1000 mm
External Dimensions W×D×H
1180×651×1616 mm
Internal Capacity
535L
Shelf Plate With Standard Load
15kg/piece
Shelf Rest Step Number / Shelf Rest Pitch
29 steps x 2 / 30mm
Power Source 50/60Hz
220V 18A (no plug, round terminal)
Weight
190kg
Shelf Plate
Stainless steel, 1pc on the bottom screwed (DKN912C, 2 pcs)
Shelf Plate / Bracket
8 pcs. / 16 pcs.

Product description

Programmable forced convection oven with 535L capacity, PID control, ±1°C accuracy, safety functions, 220V power.

Yamato DKN-912C Programmable Forced Convection Laboratory Oven (220V)

  • Capacity: 535L
  • Circulation Method: Forced air circulation
  • Temperature Range: Room temperature +10°C to 210°C
  • Temperature Accuracy: ±1°C (at 210°C)
  • Temperature Distribution Accuracy: ±2.5°C (at 210°C)
  • Heating: SUS pipe heater, 1.8 kW × 2 units
  • Maximum Temperature Reach Time: 60 minutes
  • Controller: Microprocessor PID controller, 3-program pattern, 30-step programmable with repeat function
  • Display: Green LED for measured temperature, Red LED for set temperature
  • Timer: Runs from 1 minute up to 999 hours 50 minutes with timer wait function
  • Operation Modes: Fixed temperature, Program operation, Auto start/stop, Quick auto-stop
  • Safety Features:
  • Self-diagnostic functions for sensor abnormalities, heater disconnection, SSR shorts
  • Automatic overheating prevention
  • Electric leakage breaker with overcurrent protection
  • Key lock function
  • Materials:
  • Interior: Stainless steel
  • Exterior: Cold rolled steel plate with melamine resin baking finish
  • Insulation: Glass wool
  • Fan: 2 fans, 10W each
  • Exhaust Ports: Two 30 mm I.D. ports at rear
  • Cable Hole: One 30 mm I.D. port on the right side
  • Heater Control: SSR (Solid State Relay) control
  • Sensor Type: K-type thermocouple
  • Shelving:
  • 1 or 2 stainless steel shelf plates (depending on configuration)
  • Load capacity: 15 kg per shelf
  • 29-step height adjustment, 30 mm pitch
  • Dimensions:
  • Internal (W×D×H): 1070 × 500 × 1000 mm
  • External (W×D×H): 1180 × 651 × 1616 mm
  • Power Supply: 220 V, 18 A, 50/60 Hz (no plug, round terminal)
  • Weight: 190 kg
  • Additional Functions: Calibration offset, uninterruptible memory power, self-diagnostic, key lock for safety and usability.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 9 November 2026