Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

Memmert ICO150med CO₂ Incubator-cover
Memmert ICO150med CO₂ Incubator

The appliance is intended for the creation and maintenance of constant environmental conditions for  (more)application in the field of in vitro fertilisation (IVF), especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. Working-temperature range: 5°C above ambient temperature up to 50°C Standard sterilisation program: 60 minutes at 180°C (without removing the sensors) Setting temperature range: 18 to 50°C Setting accuracy temperature: 0.1°C Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber (at 37°C): +/- 0.3 K Temperature fluctuations with time (at 37°C): +/- 0.1 K Humidity control: Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 % Setting accuracy humidity: 0.5 % rh CO₂ control: Digital electronic with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO₂: 0 to 20% Setting accuracy CO₂: 0,1% Variation in time CO₂: +/- 0.2% Max. number of internals: 10 (2 included) Max. loading of chamber: 120 kg Max. loading per internal: 15 kg Volume: 156 l Internal dimensions (WxHxD): 560 x 700 x 400 mm Dimensions (WxHxD): 719 x 1070 x 591 mm Weight: 90 kg

€4,999.00 ex VAT
Netherlands
incubators
Bandelin Sonorex RK 1028 CH Ultrasonic Water Bath-cover
Bandelin Sonorex RK 1028 CH Ultrasonic Water Bath

High-performance ultrasonic cleaner with heating for use in the practice, laboratory and workshop. T (more)he proven and particularly robust SONOREX ultrasonic baths clean thoroughly and gently by means of intensive cavitation bubbles, even in the hard-to-reach places of the cleaning objects. A user-friendly rotary handle control is used for easy setting of the cleaning time and bath temperature. The fully automatic SweepTec function prevents standing waves in the ultrasonic field and achieves particularly even cleaning. Ultrasound frequency: 35 kHz Temperature setting: 30°C – 80°C Time setting: 1-15 min, continuous operation Capacity: 45 L Work content: 30 L Level marking: yes Tub material: Stainless steel V2A (1 4301) Tub thickness: 2 mm Inner dimension (LxWxH): 500 x 300 x 300 mm Dimension (LxWxH): 540 x 340 x 500 mm Included Cover: A suitable stainless steel lid for an ultrasonic bath protects the bath fluid from external contamination and prevents odour nuisance caused by the added cleaning or disinfecting preparations. In addition, the noise emission that may be perceived as annoying during operation of the ultrasonic cleaner is reduced. The lids are designed in such a way that any condensation water that arises is led back into the tank. Hanging basket: For holding sound reinforcement material; made of stainless steel. During ultrasonic operation, nothing may be placed on the bottom of the tank, as abrasion may occur between the material to be sonicated and the ultrasonic oscillating tank. It is therefore recommended to use a suitable basket to hold the sonication material. The BANDELIN baskets are designed in such a way that the material to be sonicated is always in the optimum area of the cavitation field (1-2 cm from the floor) in the oscillating tank. With the help of a basket, the sonication material can also be conveniently placed in the unit and removed after operation, e.g. for rinsing, without the user coming into contact with the sonication fluid in the oscillating tank. Sieve holder: For cleaning test sieves in an ultrasonic bath; stainless steel. During ultrasonic operation, nothing may be placed on the bottom of the tank, as abrasion may occur between the material to be sonicated and the ultrasonic oscillating tank. It is therefore recommended to use a suitable basket to hold the sonication material. The BANDELIN baskets are designed in such a way that the material to be sonicated is always in the optimum area of the cavitation field (1-2 cm from the floor) in the oscillating tank. With the help of a basket, the sonication material can also be conveniently placed in the unit and removed after operation, e.g. for rinsing, without the user coming into contact with the sonication fluid in the oscillating tank. Insert strip: The insert strip is used to hold the insert vessels. When using chemically aggressive liquids (e.g. TICKOPUR J 80 U), removing chemically aggressive or abrasive contaminants or sonicating sample liquids, insert cups are used (indirect sonication). Because nothing may be placed on the bottom of the ultrasonic bath. Another advantage: When using an insert strip, several insert beakers can be sonicated with different liquids at the same time (e.g. removal of dental cements with STAMMOPUR Z in one and cleaning with simultaneous chemical disinfection of dental instruments with STAMMOPUR DR 8 in a second insert beaker). Please note that the surface tension of the water must be reduced in order to transfer the ultrasound to the insert vessel and therefore a cleaning solution (e.g. TICKOPUR R 33 – 3%) must be used as a coupling liquid / contact liquid.

€1,999.00 ex VAT
Netherlands
baths or circulators
IKA Dry Block Heater 2 Heating Block-cover
IKA Dry Block Heater 2 Heating Block

Digital block heater for two aluminum blocks provides precise temperature control in small vessels.  (more)Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations. Stepless adjustable temperature up to 120°C Timer: Countdown, adjustable from 1 min to 99h 59min Counter: Display of heating time Highly versatile with a large number of blocks Error code display Fixed safety circuit Acoustic signal at end of test Number of blocks: 2 Heat output: 250 W Heating temperature range: Ambient +5°C to 120°C Temperature display: yes Adjustment and display resolution: 1 K Connection for ext. temperature sensor: CT (DIN12878) PT 1000 variation;DIN EN 60751 Kl. A: ≤ ± (0.15 +0.002xITI) K Temperature stability within the blocks at 37°C: ±0.2°C Temperature stability within the blocks at 60°C: ±0.4°C Temperature Homogenity at 37°C: 0.2 K Temperature Homogenity at 60°C: 0.4 K Heatingrate / Heat up time with external sensor: 4.5 K/min Set-up plate material: Aluminium alloy Set-up plate dimensions: 96 x 152 mm Fixed safety circuit: 150°C Timer: yes Time setting range: 1 – 5999 min Dimensions (WxHxD): 151 x 73 x 304 mm Weight: 1.724 kg Blocks included: 1x DB 1.2: Used for Eppendorf microtubes (1.5 ml) Pore size: Ø 11.5 mm No. of holes: 20 Hole depth: 36.9 mm Dimensions (WxDxH): 95 x 76 x 51 mm 2x DB 5.1: Used for 12 mm vials Pore size: Ø 12.7 mm No. of holes: 20 Hole depth: 30.0 mm Dimensions (WxDxH): 95 x 76 x 51 mm 1x 13.9: Used for round bottom tubes (12/13 mm) Pore size: Ø 13.7 mm No. of holes: 16 Hole depth: 48.4 mm Dimensions (WxDxH): 95 x 74 x 51 mm

€979.00 ex VAT
Netherlands
heating & cooling
Genetix ClonePix FL Mammalian Colony Picker-cover
Genetix ClonePix FL Mammalian Colony Picker

The ClonePix FL builds on the success of the Genetix white light ClonePix adding fluorescent imaging (more) capabilities for more intelligent selection. The unique proprietary technology behind ClonePix FL represents a major advance in cell line selection and development, significantly reducing the time and costs associated with new biopharmaceutical product development especially when compared to standard techniques such as limited dilution or cell sorting. Specification: White light imaging- Trans-illumination for imaging low contrast colonies such as adherent monolayers or small colonies in suspension. Epi-illumination for imaging colonies as they are collected Fluorescence imaging- Software-controlled switching between up to 5 excitation /emission filter pairs (we recommend no more than 3 filters be multiplexed for optimal performance) Data tracking- Internal barcode reader for source and destination plates enables data tracking for each run Camera- Integrated 16-bit cooled CCD camera Imaging speed- 6-well microplate: 5 min for 2 wavelengths (standard conditions) Resolution- Standard: 28 micron; Maximum: 1.5 micron Containment- Fully enclosed working environment with Class 100-type, HEPA filtration Source plate type- PetriWell-6 plate, PetriWell-1 plate, Greiner 6 well plate, Nunc 6 well plate, Nunc OmniTray Destination plate type- PetriWell-96 plate, Costar 96 well plate, Greiner 96 well plate, Nunc 96 well plate, Falcon 96 well plate Source plate capacity- 10 plates Destination plate capacity- 10 plates Picking head- 8 x picking pins – each pin independently controlled Picking pin size- Diameter of picking pins is application specific – F1: suspension cells, F2: adherent cells Picking speed > 200 clones per hour Wash bath- Ethanol wash bath, automatically refilled Picking system fluids- 5 L sterile water supply, 5L waste bottle Pin drying- Proprietary halogen pin drying station

€14,999.00 ex VAT
Netherlands
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]