53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com
Procurable · sourced on request

BMG LABTECH CLARIOstar

UsedBMG LABTECHOptical detectorsNetherlands
Procurable

Not in stock, available to order through our sourcing team

Not in stock, but we can get it for you

We source this model through our supplier network. Request a quote and we'll come back within one hour.

  1. Request a quote
  2. We confirm price and lead time
  3. You approve, we ship to you
Detection Modes
Fluorescence Intensity, Fluorescence Polarization, AlphaScreen®, AlphaLISA®, AlphaPlex™, Luminescence (flash and glow), BRET, Time-Resolved Fluorescence, TR-FRET, UV/Vis Absorbance
Measurement Modes
Top and bottom reading, Endpoint and kinetic measurements, Sequential multi-excitation measurements, Sequential multi-emission measurements, Spectral scanning (fluorescence, luminescence, absorbance), Ratiometric measurements, Well scanning
Spectral Range
Filters: 240 - 750 nm or 240 - 900 nm for Fluorescence Intensity, Fluorescence Polarization, TRF; 240 - 750 nm for Luminescence; LVF Monochromators™: 320 - 850 nm for Fluorescence Intensity; 320 - 750 nm for Luminescence; Linear Variable Dichroic: 340 - 740 nm for Fluorescence Intensity, Luminescence; Spectrometer: 220 - 1000 nm for Absorbance
Detection Limits
Fluorescence Intensity Filters (top): < 0.15 pM; Fluorescence Intensity Filters (bottom): < 1.0 pM; Fluorescence Intensity Monochromator (top): < 0.35 pM; Fluorescence Intensity Monochromator (bottom): < 3.0 pM; Fluorescence Polarization: < 0.5 mP SD at 1 nM Fluorescein; HTRF® (black and white microplates): Delta F > 880 % (High Calibrator); Time-Resolved Fluorescence: < 20 fM Europium; Luminescence: < 0.4 pM; AlphaScreen® with Laser: < 5 pM
Microplate Formats
6- to 1536-well plates, user-definable; LVis Plate with 16 low volume microspots (2 μL)
Availability
Procurable
Lead time
Confirmed with your quote
All 28 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 28

Brands
BMG LABTECH
New/Used
Used
Dimensions
450 x 510 x 400 mm
Weight
32 kg
Detection Modes
Fluorescence Intensity, Fluorescence Polarization, AlphaScreen®, AlphaLISA®, AlphaPlex™, Luminescence (flash and glow), BRET, Time-Resolved Fluorescence, TR-FRET, UV/Vis Absorbance
Measurement Modes
Top and bottom reading, Endpoint and kinetic measurements, Sequential multi-excitation measurements, Sequential multi-emission measurements, Spectral scanning (fluorescence, luminescence, absorbance), Ratiometric measurements, Well scanning
Spectral Range
Filters: 240 - 750 nm or 240 - 900 nm for Fluorescence Intensity, Fluorescence Polarization, TRF; 240 - 750 nm for Luminescence; LVF Monochromators™: 320 - 850 nm for Fluorescence Intensity; 320 - 750 nm for Luminescence; Linear Variable Dichroic: 340 - 740 nm for Fluorescence Intensity, Luminescence; Spectrometer: 220 - 1000 nm for Absorbance
Detection Limits
Fluorescence Intensity Filters (top): < 0.15 pM; Fluorescence Intensity Filters (bottom): < 1.0 pM; Fluorescence Intensity Monochromator (top): < 0.35 pM; Fluorescence Intensity Monochromator (bottom): < 3.0 pM; Fluorescence Polarization: < 0.5 mP SD at 1 nM Fluorescein; HTRF® (black and white microplates): Delta F > 880 % (High Calibrator); Time-Resolved Fluorescence: < 20 fM Europium; Luminescence: < 0.4 pM; AlphaScreen® with Laser: < 5 pM
Microplate Formats
6- to 1536-well plates, user-definable; LVis Plate with 16 low volume microspots (2 μL)
Reagent Injection
Up to 2 built-in reagent injectors; Individual injection volumes for each well: 3 to 500 μL (optionally up to 2 mL); Variable injection speed up to 420 μL/s; Reagent back flushing
Sample Volume
3 to 500 μL per well (optionally up to 2 mL); LVis Plate compatible with 2 μL samples
Compatible Materials
Not specified
Light Sources
High energy xenon flash lamp; Dedicated laser for AlphaScreen®, AlphaLISA®, AlphaPlex™
Detectors
Low noise photomultiplier tube; CCD spectrometer
Wavelength Selection
Dual Linear Variable Filter (LVF) Monochromators™; Linear Variable Dichroic Mirror; Optical filters: Ex and Em slides hold 4 filters each
Software
Integrated fluorophore library; Multi-user Reader Control and MARS Data Analysis Software included; FDA 21 CFR Part 11 compliant
Power Supply
100 - 240 V AC, 50/60 Hz
Sensitivity
Fluorescence Intensity Filters (top): < 0.15 pM; Fluorescence Intensity Filters (bottom): < 1.0 pM; Fluorescence Intensity Monochromator (top): < 0.35 pM; Fluorescence Intensity Monochromator (bottom): < 3.0 pM; Fluorescence Polarization: < 0.5 mP SD at 1 nM Fluorescein; HTRF® (black and white microplates): Delta F > 880 % (High Calibrator); Time-Resolved Fluorescence: < 20 fM Europium; Luminescence: < 0.4 pM; AlphaScreen® with Laser: < 5 pM
Dynamic Range
9 decades
Read Times
Flying mode (1 flash): 8 s (96-well), 15 s (384-well), 28 s (1536-well); 10 flashes: 19 s (96-well), 57 s (384-well), 3 min 4 s (1536-well)
Measurement Range
9 decades
Shaking
Linear, orbital, and double-orbital with user-definable time and speed
Incubation
+3 °C above ambient up to 45 °C or 65 °C; The upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate to prevent condensation build-up on the lid or sealer
Humidity
Non-condensing
Pressure Limits
Not specified
Connectivity/Interface
USB, Ethernet; Compatible with LIMS and robotic systems; Data export to Excel, Absolute Database, or ASCII format
Availability
Procurable
Lead time
Confirmed with your quote

Product description

High-performance microplate reader with LVF monochromators, UV/Vis spectrometer, Alpha laser, and upgradable automation.

BMG LABTECH's CLARIOstar Plus is a high-performance, multi-mode microplate reader designed to deliver exceptional flexibility and sensitivity across a wide range of applications. Equipped with advanced technologies, this instrument is ideal for researchers seeking precise and reliable data in various scientific domains.

Key features include:

  • Dual Linear Variable Filter (LVF) Monochromators™: Enable seamless wavelength selection for fluorescence and luminescence assays.
  • UV/Vis Spectrometer: Provides ultra-fast absorbance measurements across a spectrum from 220 to 1000 nm.
  • Dedicated Alpha Technology Laser: Enhances performance for AlphaScreen®, AlphaLISA®, and AlphaPlex™ assays.
  • Enhanced Dynamic Range: Simplifies assay development, making it ideal for kinetic studies.
  • Rapid Full-Plate Autofocus: Ensures consistent and accurate readings across all wells.
  • Upgradable Design: Allows integration into automated systems and future expansion of capabilities.

The CLARIOstar Plus is widely utilised in fields such as biotechnology, molecular biology, drug discovery, and clinical diagnostics. Its versatility makes it suitable for applications including DNA/RNA quantification, protein analysis, cell viability assays, and enzyme kinetics.

Commonly adopted by university laboratories, biomedical research centres, and pharmaceutical companies, this microplate reader supports a broad spectrum of research needs. Since its release, the CLARIOstar Plus has remained a relevant and reliable tool in scientific research, continually meeting the evolving demands of the scientific community.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 4 November 2026