Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
MA 210.5Y Moisture Analyzer
Supplier
Radwag
Location
Radom - Poland
Price
€3,620.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag MA 210.5Y Moisture Analyzer

Radwag€3,620.00 (ex VAT)
item image

Description by the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?


If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:


It Dries in 4 Ways


The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.


The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.


The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.


You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.


The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.


What Drying Temperature Should I Set?


The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.


The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C.


How Do I Finish the Drying? In 4 Ways


The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.


Automatic mode

You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.


Manual mode

You terminate the measurement yourself by pressing the STOP button.


Time-defined mode

The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!


User-defined mode

When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.


Digital Weighing Auditor


Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.


10-Inch Display


Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.


Uncompromising User Verification


For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.


Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User


The light colour will tell you about status, process results, procedures, or alerts.


Hotspot


Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.


RFID


ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.


Live Note – Note Down Your Conclusions


It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.


Handy Library


This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.


Widgets


Prepared to display what you need most at any given moment.


21 CFR Part 11


Do you work in the pharmaceutical industry? Do you need a digital signature?


We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.


Full data security


Electronic signatures


Validations


Electronic records


Audit trails


Modbus TCP/IP


is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.


A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.


* RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details
FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag WLC 2/A2/C/2 Precision Balance-cover
Radwag WLC 2/A2/C/2 Precision Balance

Precision of WLC balances Fast, accurate and repeatable weight determination. Energy-efficient elect (more)ronics and display, combined with an internal rechargeable battery, are the perfect duo to allow you to work without access to mains power. Precision not just in the name When we designed this balance, we took care of the smallest details – both those you can’t see, hidden in the solid housing, and those you can touch. This balance is the result of a combination of our experience and true precision. The power of steel The use of stainless steel for the pan guarantees you a long life for the balance. It is not afraid of contact with moist objects or accidental splashes. It has been with us for years, and will stay for a long time to come The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient. Internal power The internal rechargeable battery combined with the energy-saving display and electronics allow many hours of operation without mains power. Time counts The balance is equipped with a real-time clock that provides accurate time measurement in a way that is independent of external power supply. There is potential Printer, computer, flash drive or additional display – you can easily connect them thanks to the fact that the balance is equipped with interfaces: 2 x RS232, USB type A and USB type B. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. Good ALIBI The ALIBI memory used in the terminal allows for safe storage of weighing records without the possibility of unauthorized interference. A single measurement remains in the ALIBI memory up to a preset limit number of days of storage, counting from the date it was taken. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€468.00 ex VAT
Poland
balances, precision balances
Radwag MY11 - Adapter for Pipettes calibration 11 ml-cover
Radwag MY11 - Adapter for Pipettes calibration 11 ml

MY11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the MYA microbalance. Set content: weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Vessel capacity: 11 ml Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
microbalances accessories, pipettes, pipettes calibration, scales, ultra & microbalances accessories, ultra microbalances, analytical balances, analytical balances accessories, balances, balances accessories, microbalances
Accuris W3100-120 Analytical Balance, 120 Grams, 0.0001 g-cover
Accuris W3100-120 Analytical Balance, 120 Grams, 0.0001 g

Accuris Analytical Balance, 120 Grams Accuris Analytical balances incorporate electromagnetic sensor (more) technology and precision mechanical components to offer superior weight determinations to a fraction of a milligram. Two capacity ranges are available in the Analytical Balance line to weigh samples up to 120g or 210g. Readability for both ranges is 0.0001g (0.1mg), with accuracy and linearity specifications that match up with the top brands in the industry. The W3100 balances tare and stabilize quickly to provide immediate results. Both ranges offer an optional “Quick-Cal” internal calibration feature that allows quick and convenient calibration without the need for a calibration standard weight. The glass draft shield enclosing the weighing chamber has sliding doors on the sides and top for easy access to the weigh pan. Leveling feet on the rear of the balance extend laterally to provide stability, and a sensitive leveling bubble aids in the leveling process. The Accuris analytical balances have feature-rich software with different modes available for basic weighing in grams, ounces or carats, piece count weighing, determining percent deviation, and also check weighing for component inspection. The large, backlit LCD control panel is easy to see and easy to use. INCLUDED: The Accuris Analytical Balance, 120 Grams includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$1,821.00 ex VAT
United States
balances, scales
People are watching right now:
Radwag F1 Mass Standard - Stainless Steel Wire -200 mg-cover
Radwag F1 Mass Standard - Stainless Steel Wire -200 mg

F1 class mass standards are exceptional measuring tools that represent the pinnacle of precision in  (more)the field of metrology. Classified as F1 metrology class, they are perfect for advanced applications where every detail of measurement is of paramount importance. F1 class standard: stainless steel wire Nominal value: 200 mg Material: stainless steel Highest Precision and Accuracy F1 class mass standards are characterized by absolute measurement precision and extraordinary accuracy. They are designed to meet the most stringent standards for acceptable deviation from actual weight. Stability under Difficult Conditions An important feature of F1 class mass standards is their ability to maintain measurement stability even under harsh environmental conditions. The standards of this class are resistant to changes in temperature, humidity and other factors that affect the precision of measurements. Calibration in Accordance with International Standards The calibration process for F1-class mass standards is rigorous and in accordance with international standards. This ensures that standards of this class are globally recognized and can be used in different countries. Specialized Construction Materials F1-class standards are often made of materials with unique physical properties. This provides them not only with precision, but also with durability and wear resistance. Applications 1. Industrial Metrology F1 class mass standards are used in metrology laboratories engaged in the testing and maintenance of measurement standards. 2. Scientific Research In scientific research, especially in high-precision fields such as physics and astronomy, F1-class mass standards are a key tool. 3. Aerospace Industry In the precision mass measurements required by the aerospace industry, F1-class standards guarantee reliability and accuracy. 4. Calibration Laboratories In calibration laboratories where uniformity and precision are a priority, F1-class mass standards are the standard of excellence. F1-class mass standards are synonymous with the highest quality and precision in the field of metrology. Their use is crucial where even the slightest deviation from the standard can carry unpleasant consequences. They are tools for advanced applications that contribute to raising standards in the field of mass measurement.

€38.00 ex VAT
Poland
mass standards
Radwag Stainless Steel Wire, Set (1 mg - 500 mg), Plastic Box-cover
Radwag Stainless Steel Wire, Set (1 mg - 500 mg), Plastic Box

Stainless Steel Wire - set (1 mg - 500 mg) F1 class mass standards are exceptional measuring tools t (more)hat represent the pinnacle of precision in the field of metrology. Classified as F1 metrology class, they are perfect for advanced applications where every detail of measurement is of paramount importance. F1 Class Mass Standards – Key Features Highest Precision and Accuracy - F1 class mass standards are characterized by absolute measurement precision and extraordinary accuracy. They are designed to meet the most stringent standards for acceptable deviation from actual weight. Stability under Difficult Conditions - An important feature of F1 class mass standards is their ability to maintain measurement stability even under harsh environmental conditions. The standards of this class are resistant to changes in temperature, humidity and other factors that affect the precision of measurements. Calibration in Accordance with International Standards - The calibration process for F1-class mass standards is rigorous and in accordance with international standards. This ensures that standards of this class are globally recognized and can be used in different countries. Specialized Construction Materials - F1-class standards are often made of materials with unique physical properties. This provides them not only with precision, but also with durability and wear resistance. The set includes: plastic box 12 mass standards 1 pair of tweezers 1 brush Material: stainless steel Application 1. Industrial Metrology F1 class mass standards are used in metrology laboratories engaged in the testing and maintenance of measurement standards. 2. Scientific Research In scientific research, especially in high-precision fields such as physics and astronomy, F1-class mass standards are a key tool. 3. Aerospace Industry In the precision mass measurements required by the aerospace industry, F1-class standards guarantee reliability and accuracy. 4. Calibration Laboratories In calibration laboratories where uniformity and precision are a priority, F1-class mass standards are the standard of excellence. F1-class mass standards are synonymous with the highest quality and precision in the field of metrology. Their use is crucial where even the slightest deviation from the standard can carry unpleasant consequences. They are tools for advanced applications that contribute to raising standards in the field of mass measurement.

€507.00 ex VAT
Poland
mass standards
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.