58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Wilson Wolf GatheRex 80000E Rev. D Media Removal and Cell Recovery Device

Price on request

In stock

Can't find what you're looking for?

Description
Serial No.: 221043. Manufactured: 2022. Electrical specifications: 100-240 VAC, 1.3 A, 50-60 Hz, 1 phase. The device conforms to UL STD 61010-1 and CSA STD C22.2 #61010-1 standards.
Technical Data
Model: 80000E - Rev. D Serial Number: 221043 Voltage: 100-240 VAC Frequency: 50-60 Hz Power Consumption: 1.3 A Fuse Rating: N/A Software Version: N/A Configuration: Media Removal and Cell Recovery Device with user interface including sample and cell filter ports, control buttons for media removal and cell recovery cycles. Manufacturing Year: 2022
Voltage
100-240 VAC
Frequency
50-60 Hz
Power Consumption
1.3 A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Wilson Wolf
New/Used
Used
Description
Serial No.: 221043. Manufactured: 2022. Electrical specifications: 100-240 VAC, 1.3 A, 50-60 Hz, 1 phase. The device conforms to UL STD 61010-1 and CSA STD C22.2 #61010-1 standards.
Technical Data
Model: 80000E - Rev. D Serial Number: 221043 Voltage: 100-240 VAC Frequency: 50-60 Hz Power Consumption: 1.3 A Fuse Rating: N/A Software Version: N/A Configuration: Media Removal and Cell Recovery Device with user interface including sample and cell filter ports, control buttons for media removal and cell recovery cycles. Manufacturing Year: 2022
Voltage
100-240 VAC
Frequency
50-60 Hz
Power Consumption
1.3 A
Fuse Rating
N/A
Software Version
N/A
Configuration
Media Removal and Cell Recovery Device with user interface including sample and cell filter ports, control buttons for media removal and cell recovery cycles.
Manufacturing Year
2022
Accessories
Sample & Cell Filter Ports, Control Buttons for Media Removal and Cell Recovery
Dimensions
N/A
Weight
N/A

Product description

Automated media removal and cell recovery device with user interface, optimized for cell processing workflows.

The Wilson Wolf GatheRex 80000E Rev. D is a specialized media removal and cell recovery device engineered for efficient cell processing in research and biotechnology laboratories. This device supports critical workflows in molecular diagnostics, bioprocessing, and biomanufacturing, offering precise control over media removal and cell recovery cycles through an intuitive user interface.

Key technical specifications include:

  • Electrical input: 100–240 VAC, 50–60 Hz, 1.3 A, single phase
  • Compliance with safety standards UL STD 61010-1 and CSA STD C22.2 #61010-1 ensures laboratory safety and reliability
  • Connectivity features include clearly labeled sample and cell filter ports, facilitating seamless integration into cell processing protocols
  • Control buttons enable precise operation of media removal and cell recovery functions, essential for workflows in synthetic biology and cellular therapeutics

This device is widely adopted in cell culture laboratories and biotechnology research requiring efficient separation of cells from culture media, and is critical in gene editing workflows and cell therapy manufacturing pipelines. Its robust design supports reproducible operation, making it a valuable asset for live-cell processing and clinical diagnostic sample preparation.

Optimized for applications in cell recovery, media exchange, and bioprocess automation, the Wilson Wolf GatheRex 80000E enhances productivity in both academic research and industry environments focusing on cell imaging, stem cell research, and immunology studies.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026