DESCRIPTION
SINGLE SOLID DOOR PHARMACY/VACCINE UNDERCOUNTER REFRIGERATOR BUILT-IN ADA COMPLIANT LEFT HINGE
OPERATIONAL ENVIRONMENT
INDOOR USE ONLY, +18°C TO +26°C (+65°F TO +78°F), <70% RH
STORAGE CAPACITY
4.6 CU. FT. GROSS VOLUME
DOOR
ONE SWING SOLID DOOR, SELF-CLOSING, RIGHT HINGED, NON-REVERSIBLE, MAGNETIC SEALED GASKET, KEYED LOCK
SHELVES
THREE SHELVES (TWO ADJUSTABLE/ONE FIXED) WITH GUARD RAIL ON BACK
All 25 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 25

Brands
American BioTech Supply
New/Used
Used
DESCRIPTION
SINGLE SOLID DOOR PHARMACY/VACCINE UNDERCOUNTER REFRIGERATOR BUILT-IN ADA COMPLIANT LEFT HINGE
OPERATIONAL ENVIRONMENT
INDOOR USE ONLY, +18°C TO +26°C (+65°F TO +78°F), <70% RH
STORAGE CAPACITY
4.6 CU. FT. GROSS VOLUME
DOOR
ONE SWING SOLID DOOR, SELF-CLOSING, RIGHT HINGED, NON-REVERSIBLE, MAGNETIC SEALED GASKET, KEYED LOCK
SHELVES
THREE SHELVES (TWO ADJUSTABLE/ONE FIXED) WITH GUARD RAIL ON BACK
MOUNTING
LOW PROFILE ROLLER WHEELS AND LEVELING LEGS
INTERIOR LIGHTING
SHIELDED, SWITCHED LED LIGHTING, FULL COVERAGE, BALANCED SPECTRUM
AIRFLOW MANAGEMENT
FORCED AIR TECHNOLOGY, PATENT PENDING
EXTERNAL PROBE ACCESS
REAR WALL PORT (1/2") DIA.
INSULATION
CABINET IS FOAMED-IN-PLACE WITH EPA COMPLIANT HIGH DENSITY URETHANE FOAM
EXTERIOR MATERIALS
WHITE POWDER COATED STEEL
ACCESS CONTROL
PYXIS®, OMNICELL® AND ACUDOSE RX® COMPATIBLE
GENERAL WARRANTY
TWO (2) YEARS PARTS AND LABOR WARRANTY, EXCLUDING DISPLAY PROBE CALIBRATION
COMPRESSOR WARRANTY
FIVE (5) YEARS COMPRESSOR WARRANTY
EXTERIOR WIDTH
23 7/8"
EXTERIOR DEPTH
24 3/8"
EXTERIOR HEIGHT
31 15/16"
PRODUCT WEIGHT
100 LBS.
SHIPPING WEIGHT
140 LBS.
RATED AMPERAGE
1.74 AMPS
POWER PLUG/POWER CORD
NEMA 5-15 PLUG, 8 TO 10 FT TYPICAL, CONFORMS TO UL471 REQUIREMENTS, VACCINE STORAGE POWER CORD WARNING LABEL
FACILITY ELECTRICAL REQUIREMENT
110-120V AC: 15 A (MINIMUM)
AGENCY LISTING AND CERTIFICATION
CERTIFIED IN ACCORDANCE WITH THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE. UL, C-UL, ETL, C-ETL LISTED (EITHER SINGLE OR DUAL AGENCY LISTINGS) AND CERTIFIED TO UL471 STANDARD, HYDROCARBON REFRIGERANT SAFETY.

Product description

Built-in 4.6 cu. ft. ADA-compliant vaccine refrigerator with NSF/ANSI 456 certification and microprocessor control.

General Features:

  • Designed per NSF/ANSI 456 Standard for Vaccine Storage
  • ADA compliant, left hinged, solid self-closing door with magnetic gasket and keyed lock
  • Capacity: 4.6 cu. ft. gross volume
  • Three shelves (two adjustable, one fixed) with back guard rail
  • Low profile roller wheels and leveling legs for mobility and stability
  • Shielded, switched LED interior lighting providing balanced spectrum coverage
  • Forced air technology (patent pending) for airflow management
  • Rear wall probe access port (1/2" diameter) with included calibrated stainless steel temperature probe
  • White powder-coated steel exterior
  • EPA compliant, high density urethane foam insulation (foamed-in-place)
  • Compatible with Pyxis®, Omnicell®, and Acudose RX® access control systems
  • Includes CDC-compliant temperature monitor device (TMD) with min/max memory, audible/visual alarms, F/C switchable, field installable, 3-year calibration certification
  • Pharmacy refrigerator/freezer toolkit and temperature logs included

Environmental and Electrical Specifications:

  • Indoor use only, ambient temperature +18°C to +26°C (+65°F to +78°F), <70% RH
  • Electrical: 110-120V AC, 15 A minimum, NEMA 5-15 plug, 8 to 10 ft power cord, UL471 compliant
  • Rated amperage: 1.74 Amps

Refrigeration System:

  • Hermetic, high-performance compressor
  • EPA SNAP compliant R600a (Isobutane) hydrocarbon refrigerant
  • Hybrid fin and tube condenser with low noise fan
  • Plate wall evaporator
  • Cycle optimized, zero energy defrost

Performance:

  • Air temperature uniformity: ±0.8°C
  • Air temperature stability: ±1.2°C
  • Maximum temperature variation: ±1.4°C
  • Temperature rise after 8-second door openings does not exceed 6.4°C at any probe
  • Recovery to under 8°C within 4.8 minutes after 3-minute door opening
  • Energy consumption: 1.15 KWH/day
  • Heat rejection: 1.57 KWH/day (224 BTU/h)
  • Noise level: ≤43 dBA installed
  • Pull down time to nominal operating temperature: 35 minutes
  • Performance data measured with NSF/ANSI 456 compliant validation ballast probes at 22°C ambient

Temperature Controller:

  • Parametric microprocessor with LED display, 0.1°C resolution
  • Setpoint range: 1°C to 10°C (must remain factory set for NSF/ANSI compliance)
  • Visual and audible alarms for high/low temperature, compliant with NSF/ANSI 456 alarm requirements
  • Remote alarm contacts for external alarm connection
  • Simulator ballast included (20 mL glass bead thermal media bottle)

Certifications and Warranty:

  • Certified to NSF/ANSI 456 Standard for Vaccine Storage
  • UL, C-UL, ETL, C-ETL certification to UL471, hydrocarbon refrigerant safety
  • Two (2) years parts and labor warranty (excludes display probe calibration)
  • Five (5) years compressor warranty

Dimensions and Weight:

  • Exterior width: 23 7/8"
  • Exterior depth: 24 3/8"
  • Exterior height: 31 15/16"
  • Product weight: 100 lbs
  • Shipping weight: 140 lbs

Shipping Options:

  • Multiple freight delivery options available including dock to dock, liftgate services, inside delivery with installation assistance (end user responsible for plugging in and temperature settings)

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026