Certifications/Compliance
NSF/ANSI 49, UL, CE
Type
Class II, Type A2
Chamber Material
Stainless Steel (1347) or Coated (1387)
Nominal width
6ft (1377 and 1347)
Interior Dimensions
71x18x30″ (1377 and 1347)
All 17 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 17

Brands
Thermo Fisher Scientific
New/Used
Used
Certifications/Compliance
NSF/ANSI 49, UL, CE
Type
Class II, Type A2
Chamber Material
Stainless Steel (1347) or Coated (1387)
Nominal width
6ft (1377 and 1347)
Interior Dimensions
71x18x30″ (1377 and 1347)
Sash Opening
10″ (1377 and 1347)
Exhaust Volume
30L
Filter Efficiency
99.995% MPPS
Filter Type
H14 HEPA EN 1822, 99.995% MPPS
Load Bearing Capacity
110 lb. (50kg)
Service Fixture Places
6 (3 on each side)
Noise Level
65 dBA
Dimensions (L x W x H) Exterior
75x30x62″ (1377 and 1347)
Weight
617 lbs (1377 and 1347)
Electrical Requirements
120V, 50/60Hz, 10A

Product description

Class II A2 biosafety cabinet with 99.995% HEPA filtration, energy-efficient brushless motor, and programmable UV lamp.

The Thermo Scientific 1300 Series A2 Biosafety Cabinet is engineered for biomedical research, clinical diagnostics, and bioprocessing environments requiring stringent containment and operator protection. It features a Class II, Type A2 biological safety cabinet design that provides personnel, product, and environmental protection through high-efficiency particulate air (HEPA) filtration with 99.995% MPPS efficiency.

Key technical specifications include:

  • HEPA filter Type H14 EN 1822 with 99.995% MPPS filtration efficiency ensures removal of airborne contaminants, critical for molecular diagnostics and biopharmaceutical production pipelines.
  • A brushless AC motor reduces energy consumption and heat output, minimizing air conditioning costs essential for long-term biomanufacturing facilities.
  • Programmable UV lamp (model 1387) enables up to 24 hours of automated decontamination, supporting aseptic workflows in gene editing and synthetic biology research.
  • Ergonomic features such as 10° angled single-piece stainless steel or coated work surfaces and armrests optimize user comfort during extended use in live-cell imaging and cell culture labs.
  • Audible and visual alarms, including a smart flow indicator, monitor airflow and cabinet status to maintain compliance with NSF/ANSI 49 and UL/CE certifications.
  • Dimensions accommodate a nominal 6 ft width with spacious 71 x 18 x 30-inch interior for unobstructed laboratory operations.

This biosafety cabinet is widely adopted in biotechnology, clinical microbiology, and industrial biosafety applications where containment and sterile environments are critical. Its quiet operation, advanced airflow control, and robust construction make it an essential instrument for molecular cloning workflows and bioprocess containment.

Electrical requirements are 120V, 50/60 Hz, 10A. The unit supports up to 110 lb (50 kg) load capacity and includes six service fixtures for utilities integration.

Overall, the Thermo Scientific 1300 Series A2 Cabinet offers a reliable, efficient solution for laboratories focused on molecular diagnostics, biomanufacturing, and synthetic biology, providing critical protection and performance in biosafety-controlled environments.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026