58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Pall iCELLis 500+ Bioreactor Control System for Scalable Cell Culture

Price on request

In stock

Can't find what you're looking for?

Description
The Pall iCELLis 500+ Control System is designed for scalable cell culture bioreactor control. It operates on 208/230 VAC with 50/60 Hz frequency. The system includes a touchscreen interface for process monitoring and control. It features a Watson Marlow pump module (NEMA 4X, IP66 rated) integrated for fluid handling. The system is equipped with an emergency stop button and power control switches. The control system supports 1 phase on 230 VAC or 2 phases on 208 VAC with a 20A full load current under 208 VAC and 32A input breaker. The system weight is approximately 650 kg.
Technical Data
Model: iCELLis 500+ Serial Number: ICL500+_A_047 Voltage: 208/230 VAC Frequency: 50/60 Hz Power Consumption: 250 VA (Watson Marlow Pump), 1.9 kW (LAUDA RP 240 B chiller) Fuse Rating: 32A input breaker Software Version: N/A Configuration: Integrated touchscreen control panel, Watson Marlow Pumps N Module - Standard (NEMA 4X, IP66), Emergency stop and power control switches, LAUDA RP 240 B chiller unit Manufacturing Year: 2019
Voltage
208/230 VAC
Frequency
50/60 Hz
Power Consumption
250 VA (Watson Marlow Pump), 1.9 kW (LAUDA RP 240 B chiller)
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Pall
New/Used
Used
Description
The Pall iCELLis 500+ Control System is designed for scalable cell culture bioreactor control. It operates on 208/230 VAC with 50/60 Hz frequency. The system includes a touchscreen interface for process monitoring and control. It features a Watson Marlow pump module (NEMA 4X, IP66 rated) integrated for fluid handling. The system is equipped with an emergency stop button and power control switches. The control system supports 1 phase on 230 VAC or 2 phases on 208 VAC with a 20A full load current under 208 VAC and 32A input breaker. The system weight is approximately 650 kg.
Technical Data
Model: iCELLis 500+ Serial Number: ICL500+_A_047 Voltage: 208/230 VAC Frequency: 50/60 Hz Power Consumption: 250 VA (Watson Marlow Pump), 1.9 kW (LAUDA RP 240 B chiller) Fuse Rating: 32A input breaker Software Version: N/A Configuration: Integrated touchscreen control panel, Watson Marlow Pumps N Module - Standard (NEMA 4X, IP66), Emergency stop and power control switches, LAUDA RP 240 B chiller unit Manufacturing Year: 2019
Voltage
208/230 VAC
Frequency
50/60 Hz
Power Consumption
250 VA (Watson Marlow Pump), 1.9 kW (LAUDA RP 240 B chiller)
Fuse Rating
32A input breaker
Software Version
N/A
Configuration
Integrated touchscreen control panel, Watson Marlow Pumps N Module - Standard (NEMA 4X, IP66), Emergency stop and power control switches, LAUDA RP 240 B chiller unit
Manufacturing Year
2019
Accessories
Watson Marlow Pumps N Module - Standard, LAUDA RP 240 B chiller unit
Dimensions
N/A
Weight
650 kg

Product description

Advanced control system with touchscreen interface for scalable cell culture bioprocessing and precise parameter management.

The Pall iCELLis 500+ Control System is a specialized bioreactor control platform designed to manage scalable cell culture processes essential for biotechnology and bioprocessing applications. Key features include:

  • Integrated touchscreen interface for intuitive monitoring and adjustments
  • Precise control modules managing parameters such as pH, dissolved oxygen, temperature, and agitation
  • Engineered for high reliability and stability in continuous bioprocessing environments
  • Compatible with scalable fixed-bed bioreactor systems widely adopted in synthetic biology, molecular diagnostics, and biomanufacturing workflows
  • Supports real-time data acquisition and process control critical in gene editing and cell therapy production pipelines

This control system is essential for researchers and professionals in bioreactor-based cell cultivation, enabling optimized conditions for mammalian and microbial cell growth. Its application spans bioprocess development, process scale-up, and production of biologics, making it a critical tool in modern biotechnology and pharmaceutical manufacturing.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026