Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

WATERS ALLIANCE 2695 + 2487 DAD HPLC-cover
WATERS ALLIANCE 2695 + 2487 DAD HPLC

For sale: Refurbished WATERS ALLIANCE 2695 HPLC Pricing: from EUR 9500,- till EUR 12.000,-  (please  (more)ask for official quote) Refurbished including:  2695 module  2487 Dual Absorbance Detector DAD  Software and computer Cables and connectors Also available: Other type of Detectors available like PDA Other brands of HPLC like Agilent and Thermo More refurbished parts for Waters HPLC systems All our products are fully tested and delivered with warranty   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! Waters 2695 HPLC System Specifications Number of solvents One to four Solvent conditioning Vacuum degas, two (2) operating modes, four (4) chambers, ≈<500 uL internal volume per chamber> <500uL interval volume per chamber Programmable flow rate range 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. increments Typical operating flow rate range 0.050 to 5.000 mL/min in 0.001-mL/min increments Compressibility compensation Automatic and continuous Effective system delay volume <650 µL, independent of backpressure @ 1 mL/min Plunger seal wash Integra, active, programmable Gradient profiles Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] Dry prime/wet prime Automatic, front panel control Flow ramping Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate Maximum operating pressure 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min. Pressure ripple ≤2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure) Composition accuracy ±0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm]) Composition precision ≤0.15% RSD or ≤0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) Flow precision ≤0.075% RSD or ≤0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix Flow accuracy ±1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure

Netherlands
hplc systems
Agilent G1316B TCC SL Thermostatted column compartment-cover
Agilent G1316B TCC SL Thermostatted column compartment

For sale: refurbished Agilent 1200 Series G1316B TCC SL Thermostatted Column Compartment   Also avai (more)lable: Agilent 1100 series G1316 Thermostatted column compartment (TCC) Agilent 1100 series and 1200 series modules like pump, degassers, detectors, autosamplers Complete 1100 and 1200 series HPLC systems   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! The Agilent 1200 Series thermostatted column compartments are stackable temperature-controlled column compartments for LC. They are available as standalone modules or as a component of a Agilent 1200 Series system. They are used for heating and cooling to meet extreme requirements of retention time reproducibility. The main features are: • Peltier heating and cooling from 10 degrees below ambient up to 80 °C(G1316A) or 100 °C (G1316B SL/G1316C SL Plus) with high heating and cooling speeds for maximum application flexibility and stability, • holds up to three 30-cm columns and optimized design gives minimum dead volumes and maximum efficiency, • two independently programmable heat exchangers contribute volumes of only 3 and 6 µl, • G1316B SL features additional heating and cooling devices for low flow rates, which reduce the risk of additional dispersion, • G1316B SL and G1316C SL Plus can be supplemented by a kit to install a small heat-exchanger with 1.6 µl delay volume to reduce the delay volume. In additon a cooling device with 1.5 µl is available, • electronic column-identification module as standard for GLP documentation of column type, and major column parameters, • optional high-quality Rheodyne® column switching valves with ceramic stator-face assemblies for prolonged lifetime.

Netherlands
thermostats
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]