Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: 2 Solvent cabinets 2 Capillary pumps 1 Well-plate samplers 2 Autosampler thermostat (more)s 1 Thermostatted colomn compartment 1 Diode array detector 1 Handheld control module Vacuum degasser cel is missing in the vacuum degasser Capillary pump: Settable column flow range: 0.01 – 20 µl/min Recommended column flow range: 1 – 20 µl/min Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) Optimum composition range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting Delay volume: Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Pressure range: 20 to 400 bar (5880 psi) system pressure Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. Well-plate sampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Autosampler thermostat: Temperature range: setable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient temperatures < 25 °C and humidity < 50%: – 1°C to + 4 °C at a setpoint of 4 °C Temperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%: – 1°C to + 5 °C at a setpoint of 4 °C Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. Handheld control module: The control module provides complete local control and monitoring of a single module or an entire Agilent series system. There is no data evaluation in the control module. The control module allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses.

€9,999.00 ex VAT
Netherlands
hplc systems
Thermo Konelab T30i Clinical Chemistry System-cover
Thermo Konelab T30i Clinical Chemistry System

Konelab 30 is a random access clinical chemistry system for routine and special chemistries, includi (more)ng specific proteins, electrolytes, therapeutic drugs, and drugs of abuse tests. The broad range of CE marked applications can be complemented with user definable tests. Throughput Workload dependent, being in typical routine use up to 300 tests/hour. Time to first result is typically 3 to 12 minutes. Samples: Continuous access to samples without interrupting test processing. Integrated barcode reader and cup/tube recognition. Sample and tubes: 0.5 ml and 2.0 ml cups, 5 ml and 7 ml tubes, 10 ml tubes with tailored segments. Sample types: Serum, plasma, urine, CSF. Sample volumes: Possible range 1-120 µl ; typically 2-15 µl and 50 µl for Na+, K+ and Cl- ISE tests. Reagents: Continuous access to reagents without interrupting test processing. Automated indentification by integrated barcode reader. Real time reagent status clearly displayed. Up to four reagent additions / test possible. On board storage: 45 positions in the refrigerated reagent compartment. Photometric Measurement: Single channel interference filter photometer with beam splitting reference – 11 fixed filters. Spectral Range: 340-800nm. Measurement principles: Colorimetric, turbidimetric Measurement modes: Kinetic, end-point Kinetic measurement: 30 sec to 60 min, max 12 points Light source: Halogen lamp with linear absorbance range of 0-2.5A, resolution of 0.001A and reproducibility of SD≤0.005A at 2A. ISE Measurement in the model Konelab 30i Direct potentiometry: Electrodes for Na+, K+ and Cl- (included),  (upon request at manufacturer) Li+,Ca2+ and pH. Usable range: K+ 2.0 – 10 (mmol/l) serum, plasma Na+ 100 – 200 (mmol/l) serum, plasma Cl- 55 – 150 (mmol/l) serum, plasma Ca2+ 0.5 – 6.0 (mmol/l) serum, plasma pH 6 – 8.5 Li+ 0.2 – 4.0 (mmol/l) serum K+ 20 – 200 (mmol/l) urine Na+ 20 – 200 (mmol/l) urine Including: Powervar Uninterruptible power supply in case of power outage. Documentation and software Dimensions (h x w x d): 1150mm x 1200mm x 790mm Weight: 200kg 230V / 50-60Hz / 700W

€14,999.00 ex VAT
Netherlands
general laboratory equipment other
Bio-Rad MyCycler Thermal Cycler System 1709703-cover
Bio-Rad MyCycler Thermal Cycler System 1709703

Bio-Rad MyCycler Thermal Cycler System 1709703 The Biorad MyCycler is a sleek 96 well PCR system use (more)d for gene amplification. The Bio-Rad MyCycler comes equipped with a large graphical display and a self-adjusting heated lid which accurately maintains temperature level across each well. The PCR comes with easy to use intuitive controls which allow the end user to program their own PCR runs with a few click of buttons. In addition, the BioRad MyCycler comes with built-in programs to quickly allow you to run the Thermal Cycler within minutes of startup. The fixed 96 well block accommodates 0.2ml PCR tubes, strips or standard 96 well plates. The BioRad MyCycler comes with USB ports situated on the rear of the machine to allow the user to save their data and take with them as they go. Moreover, there a number of built-in utilities included with this Thermal Cycler including a self-diagnostic featuring showcasing the health of the instrument. This reliable PCR system has a ramping rate of 2.5°C per second and temperature accuracy of ±0.5°C.   Contact us today to learn more about our BioRad MyCycler PCR system.   Capacity : 1 x 96 well (0.2ml) Heating rate : Up to 2.5°C/sec Cooling rate : Up to 1.5°C/sec Temperature Range : 4–100°C Accuracy : ±0.5°C Uniformity : ±0.5°C Heated lid : Up to 110°C Temperature gradient Range : 40–99°C 220-240 V | 4 A | 50/60 Hz | 910 VA This unit is in excellent working condition and very clean cosmetically. Feel free to contact with any questions.

€2,950.00 ex VAT
Netherlands
pcr equipment
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]