Measuring Range Temp
0 to +50°C (output can be set to -20 to +80°C, -50 to +50°C or 0 to +100°C)
Measuring Range Air velocity
0 to 5, 0 to 10, 0 to 15, 0 to 20 or 0 to 30 m/s
Accuracy
Temperature: ±0.3% of reading ±0.25 °C; Air velocity: ±3% of reading ±0.05 m/s (0 to 3 m/s), ±0.2 m/s (3 to 30 m/s)
Resolution
Temperature: 0.1 °C; Air velocity: 0.01 m/s (0 to 3 m/s), 0.1 m/s (3 to 30 m/s)
Output
Maximum load: 500 Ohms (4-20 mA); Minimum load: 1 kOhms (0-10 V)
All 13 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 13

Brands
KIMO Instruments
New/Used
Used
Measuring Range Temp
0 to +50°C (output can be set to -20 to +80°C, -50 to +50°C or 0 to +100°C)
Measuring Range Air velocity
0 to 5, 0 to 10, 0 to 15, 0 to 20 or 0 to 30 m/s
Accuracy
Temperature: ±0.3% of reading ±0.25 °C; Air velocity: ±3% of reading ±0.05 m/s (0 to 3 m/s), ±0.2 m/s (3 to 30 m/s)
Resolution
Temperature: 0.1 °C; Air velocity: 0.01 m/s (0 to 3 m/s), 0.1 m/s (3 to 30 m/s)
Output
Maximum load: 500 Ohms (4-20 mA); Minimum load: 1 kOhms (0-10 V)
Power supply
Active sensor 0-10 V or 4-20 mA (supply 24 Vac/Vdc ± 10%), 3-4 wires
Power Consumption
40 mA (0-10 V) or max. 80 mA (4-20 mA)
Measured Parameters
Air Velocity, Temperature
Product Type
Temperature Transmitters
Temperature Range
0 to 50 °C
Output Signal
4–20 mA, 0–10 V

Product description

Kimo CTV 110 temperature and air velocity transmitter measuring 0 to 30 m/s and 0 to 50 °C for laboratory environmental monitoring.

The Kimo CTV 110 temperature and air velocity transmitter measures airflow velocity and temperature for environmental monitoring in life sciences laboratories.

The unit measures air velocity from 0 to 30 m/s and temperature from 0 to 50 °C. No additional modules, accessories or software are specified.

This used unit has not been tested.

Measurement

  • Measures air velocity from 0 to 30 m/s.
  • Measures temperature from 0 to 50 °C.
  • Suitable for laboratory environmental monitoring and airflow measurement.

Configuration and condition

  • Model: Kimo CTV 110
  • Used condition.
  • This unit has not been tested.

What these specifications mean

The 0 to 30 m/s air velocity range covers airflow measurement for laboratory ventilation and environmental monitoring applications.

The 0 to 50 °C temperature range supports monitoring within standard ambient laboratory conditions.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 28 November 2026