Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Analytical instruments

Explore High-Precision Analytical Instruments at QuestPair. Discover our wide range of analytical instruments, designed to deliver accurate and reliable measurements for your laboratory needs. From spectroscopy to chromatography, our instruments are essential for achieving precise analysis in research, quality control, and beyond.

Mettler Toledo RE40D Refractometer-cover
Mettler Toledo RE40D Refractometer

The RE40D refractometers is used to easily determine the refractive index of liquids. The measuremen (more)ts are carried out using the total reflection method. With this method, even dark samples can be measured easily. Thanks to the latest technology – no moving parts, durable LED light source and resistant sapphire prism, the RE refractometers are virtually maintenance-free Measure liquids with a refractive index in a range from 1.32000 to 1.7000 Require a minimal amount of sample (approx. 0.4 milliliters) for the measurement Keep the temperature of the samples to be measured between  15.00 and 70.00°C thanks to a built-in Peltier thermostat (no water bath required) Calculate the refractive index of the samples for any reference temperatures based on user-defined temperature functions Show the refractive index of the samples directly in Brix degrees Able to convert the measured values into any units (e.g. Zeiss number) and display them directly in these units Suitable for concentration determinations. Concentrations are due to custom formulas or concentration tables are automatically calculated from the measured refractive index. Deliver statistical evaluations (mean value, standard deviation, relative standard deviation) of the results. Entry of 10 measurement methods. One of these methods is reserved for adjusting the device. Can be easily checked with the built-in check function. This function allows a regular checking of the measurement accuracy without changing the device settings Three serial ports for connecting a printer, a barcode reader and a computer and a connection for controlling an automation unit Including RS-P42 printer

€2,999.00 ex VAT
Netherlands
refractometers
Shimadzu UV-1800 UV/Vis Spectrophotometer-cover
Shimadzu UV-1800 UV/Vis Spectrophotometer

The UV-1800 is an advanced high-resolution spectrophotometer utilizing a precision Czerny-Turner opt (more)ical system. Operation can be either as a stand-alone instrument or as a PC-controlled instrument with the included UV Probe software. USB memory can be connected directly to the UV-1800 for simple data transfer and printing is possible with the optional screen-copy printer or printers that support PCL control codes. Photometric Mode measures the absorbance or transmittance at a single wavelength or at multiple (up to eight) wavelengths. In multiple-wavelength measurement, calculations can be performed on the data obtained for up to four wavelengths, including the calculation of the difference between, or ratio of, the measurements obtained for two wavelengths. Spectrum Mode obtains sample spectra using wavelength scanning. Changes in the sample can be tracked using repeated scans. Data processing operations, such as the enlargement or reduction of the spectra obtained, peak detection, and area calculations, are also possible. Quantitation Mode generates a calibration curve from standard samples, and uses it to calculate the concentrations of unknown samples. Various combinations of wavelengths (1 to 3 wavelengths and derivatives) and calibration curves (K-factor and first-to-third order regression calibration curves) are possible. Kinetics Mode measures the change in absorbance as a function of time, and calculates enzymatic activity values. You can select either the kinetics measurement method or the rate measurement method. Time-Scan Mode measures the change in absorbance, transmittance, or energy as a function of time. Multi-Component Quantitation Mode separately quantitates up to eight components mixed in a single sample. Pure components or mixtures of components can be used as standard samples. Biomethod Mode is capable of analyzing DNA and proteins using the several common quantitation methods including quantitation of DNA or protein using the absorbance at 260/230 nm or 260/280 nm and protein quantitation via the Lowry method, BCA method, CBB method, Biuret method, and UV absorption method (direct measurement at 280 nm). Security and validation functionality are also preprogrammed. Security functions allow you to restrict functions according to three user levels: administrator, developer, and operator. Automatic or semiautomatic validation functions include wavelength accuracy, wavelength repeatability, resolution, stray light, photometric accuracy, photometric repeatability, baseline flatness, baseline stability, and noise level. The operating time of the lamps can be recorded and displayed so that you can anticipate replacement and avoid downtime. Stray Light: <0.02%T at 340 nm, 400 nm; <1.0%T at 198 nm Source Lamp: Deuterium; Tungsten-Halogen Beam Type: Double Bandwidth: 1.0 nm Min Wavelength: 190 nm Max Wavelength: 1100 nm Wavelength Accuracy: ±0.1 nm Wavelength Reproducibility: ±0.1 nm Min Photometric – Transmittance: 0%T Max Photometric – Transmittance: 400%T Min Photometric – Absorbance: -4 A Max Photometric – Absorbance: 4 A Photometric Drift: <0.0003 A/hr Detector: Silicon photodiode Including UV Probe software

€2,499.00 ex VAT
Netherlands
spectrophotometers uv vis & fluor
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
Perkin Elmer 343 Polarimeter-cover
Perkin Elmer 343 Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters

QuestPair Analytical Instruments: Your Partner in Precision

In today's fast-paced scientific landscape, the accuracy of your data is non-negotiable. QuestPair’s analytical instruments are designed to meet the exacting standards of modern laboratories, providing the reliability and precision needed to drive your research forward. Whether your focus is on chemical analysis, materials testing, or environmental monitoring, our instruments are engineered to deliver clear, consistent results every time.

Our Analytical Instruments: Key Features

Each instrument in our collection is equipped with features that ensure top-tier performance:

  1. Precision Engineering: Every instrument is fine-tuned to deliver measurements with the highest degree of accuracy, essential for complex analyses.
  2. Robust Design: Built to last, our instruments can handle the demands of intensive laboratory use, providing you with reliable data over the long term.
  3. Versatility: From spectroscopy to chromatography, our range covers multiple analytical techniques, making them adaptable to various scientific disciplines.
  4. Ease of Use: User-centric interfaces and straightforward operation make our instruments accessible, even for complex procedures, enhancing lab efficiency.

Applications Across Multiple Disciplines

QuestPair’s analytical instruments are indispensable tools across various fields:

  • Chemical Analysis: Achieve accurate quantitative and qualitative analysis with instruments designed for high sensitivity and specificity.
  • Materials Testing: Our instruments support the testing and characterization of materials, ensuring they meet required standards and specifications.
  • Environmental Monitoring: Reliable measurements for environmental assessments, including air, water, and soil analysis, are made possible with our advanced tools.

Why Choose QuestPair?

QuestPair is committed to providing you with analytical instruments that not only meet but exceed industry standards. Our products are backed by expert support, ensuring you have access to the guidance and information you need to make the most of your investment.

Consult with Our Experts for personalized advice on selecting the right analytical instruments for your laboratory. Contact us today to enhance your lab’s analytical capabilities with the precision and reliability that QuestPair is known for.

Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]