Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

BMG Labtechnologies NOVOstar Microplate Fluorometer-cover
BMG Labtechnologies NOVOstar Microplate Fluorometer

Detection Modes: Fluorescence Intensity – including FRET Fluorescence Polarization Luminescence  (more)(flash and glow) Time-Resolved Fluorescence – including DELFIA UV/Vis absorbance Measurement Modes: Top and bottom reading Endpoint and Kinetic measurements Sequential Multi Excitation measurements Sequential Multi Emission measurements Simultaneous Dual Emission measurements Ratiometric measurements Well Scanning Microplate Formats: 6 to 384-well plates, user-defi nable Microplate Carrier: Accomodates two plates: one reagent plate and one measurement plate Light Source: High energy xenon flashlamp Detectors: Side window photomultiplier tube Optical Filters: Excitation and emission filter wheels for 8 filters each Spectral Range: 240 to 740 nm or 240 to 900 nm Sensitivity: FI: < 1 fmol / well Fluorescein FP: < 5 mP standard deviation at 1 nM fluorescein TRF: < 70 amol/well Europium LUM: < 30 amol/well ATP, DLReady certified ABS: Dynamic range: ±0.000 – 4.000 OD, Reproducibility: ±0.010 OD for 0 – 2 OD range Read Times: Flying mode: 14 s (96), 27 (384) Reagent Injection: Up to 2 built-in reagent injectors Injection at measurement position (6 to 384-well) Individual injection volumes for each well (3 to 350 µL) Variable injection speed up to 420 µL / s Up to four injection events per well Reagent back flushing Pipettor System: Injection volume: 0.5 µl – 100 µl Individual injection volumes for each well Variable injection speed Plate-to-plate transfer + 3 reagent stations + washing station Shaking: Linear, orbital, and double-orbital with user-defi nable time and speed Gas Vent: System to inject an atmosphere or to pull a vacuum into the reader Incubation: +5°C above ambient up to 45°C or 60°C Equipped with the following filters: Em: 510 – 520 – 530 – 590 – 630 nm Ex: 355 – 390 – 405 – 436 – 440 – 485 – 510 – 544 nm Dimensions (h x w x d): 300mm x 780mm x 530mm Weight: 55 kg 230V / 50-60Hz

€999.00 ex VAT
Netherlands
general laboratory equipment other
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]