There is a large assortment of scientific facilities and equipment that is used for scientific research and industrial purposes. Besides the major well-known brands producing their models in high volume, there are many innovative companies and organisations designing and manufacturing exciting new instruments for chemical, physical and biological applications and analysis. At the same time, many suppliers and re-sell (more)ers increasingly focus on the re-use of existing used laboratory equipment. This drive towards a more circular economy offers unique opportunities for institutes and organisations to obtain valuable scientific instruments at a discount.

SRI 8610C GC Gas Chromatograph System Lab-cover
SRI 8610C GC Gas Chromatograph System Lab

Reason for return - Investigate faults and re-list accordingly: - We received the item with a cracke (more)d glass piece to the photoionization detector. We replaced it with a piece that was provided. - We piped the system with N2 carrier gas and gas lines carrying product to the inlet of the GC. We turned on the switch to the Photoionization detector, under high sensitivity, and can visibly see it turn on. The source is aligned. The detector is aligned.  - We programmed the event on the software to turn the valve of the 10-way valve accordingly to enable the carrier gas to bring the product through the GC. - We introduced acetone via the sample loop (inlet gas) - we saw no peaks. We introduced acetone via injection - we saw no peaks.  - I leaked checked the piping including within the detector - no issues. I checked the point of outlets to make sure flow is continuous too - no issues. - The mechanism of the valve turning - it made a cranky sound, and I am not convinced it is turning the valve.  - There may be two issues. I had figured it was the valve so I tried injecting acetone directly into the line, but we could not see any peak of acetone. (Issues with the detector?) I am not sure if the valve's squeaking/cranky sound implies it is turning but there might be an issue here too. This SRI 8610C GC Gas Chromatograph System was removed from a university lab where it was surplus to requirements. The unit powers up but we were unable to test it further at our facility. The lab did confirm however, that is in good working order. It is in very good cosmetic condition with only very minor marks from use.

£1,540.00 ex VAT
United Kingdom
gc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]