Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Varian
Model
Varian Cary 50 UV-Vis
Supplier
LabMakelaar Benelux B.V.
Location
Zevenhuizen - Netherlands
This item is
Not available
State of item
used
Categories

Varian Cary 50 UV-Vis Spectrophotometer

LabMakelaar Benelux B.V.
item image

Description by the supplier

Dual beam, Czerny-Turner monochromator, 190–1100 nm wavelength range, approximately 1.5 nm fixed spectral bandwidth, full spectrum Xe pulse lamp single source with exceptionally long life, dual Si diode detectors, quartz overcoated optics, scan rates up to 24000 nm/min, 80 data points per s maximum measurement rate, non-measurement phase stepping wavelength drive, room light immunity, central control by PC with Microsoft Windows operating system.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Memmert ICO150med CO₂ Incubator-cover
Memmert ICO150med CO₂ Incubator

The appliance is intended for the creation and maintenance of constant environmental conditions for  (more)application in the field of in vitro fertilisation (IVF), especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. Working-temperature range: 5°C above ambient temperature up to 50°C Standard sterilisation program: 60 minutes at 180°C (without removing the sensors) Setting temperature range: 18 to 50°C Setting accuracy temperature: 0.1°C Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber (at 37°C): +/- 0.3 K Temperature fluctuations with time (at 37°C): +/- 0.1 K Humidity control: Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 % Setting accuracy humidity: 0.5 % rh CO₂ control: Digital electronic with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO₂: 0 to 20% Setting accuracy CO₂: 0,1% Variation in time CO₂: +/- 0.2% Max. number of internals: 10 (2 included) Max. loading of chamber: 120 kg Max. loading per internal: 15 kg Volume: 156 l Internal dimensions (WxHxD): 560 x 700 x 400 mm Dimensions (WxHxD): 719 x 1070 x 591 mm Weight: 90 kg

€4,999.00 ex VAT
Netherlands
incubators
Polyscience CA02A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V-cover
Polyscience CA02A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V

Polyscience CA02A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, 1/4HP, 120V, 60HzFeat (more)ures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA02A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, 1/4HP, 120V, 60Hz is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA02A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, 1/4HP, 120V, 60Hz Specifications Part NumberCA02A1P1-41AA1NCooling Capacity @ 20°C0.85 kWCooling Capacity @ 10°C0.6 kWCooling Capacity @ 0°C0.4 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range45 to 100 psi / 310 to 689 kPaMaximum Pump Flow Rate2.6 gpm / 9.8 lpmPower Requirements120V, 60Hz, 13.6AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(2) { background-color: #fffacd; }

$6,543.00 ex VAT
United States
heating & cooling, chillers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]