Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Pipettes

Pipettes are tubular instruments that are used to measure and transfer liquid volumes.

Radwag 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes-cover
Radwag 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes

RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict s (more)tandards concerning manufacturing cleanliness and biodegradability of the product. The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button. All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user. Calibration certificates, issued by the accredited calibration laboratory are available on request. Features: Large and readable display that is fully visible during pipetting; Innovative soft grip preventing heat transfer to the pipette inside; Low pressure required to use the pipette reduces the risk of RSI; Simple click mechanism for changing the pipette volume; Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure; Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion; Ultra UV resistance; Convenient button for changing the tips; Compatible with most of the tips available on the market.

Poland
pipettes calibration, pipettes
Radwag AP-12.5Y  Automatic Device for Multichannel Pipette Calibration-cover
Radwag AP-12.5Y Automatic Device for Multichannel Pipette Calibration

The AP-12.5Y is designed to calibrate multichannel pipettes starting at 10 μl. The device feature (more)s a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes. Because the pipette calibration on the AP-12.5Y is fully automatic, it is four times faster. The calibration procedure for a 12-channel pipette takes less than 20 minutes, not six hours, on this instrument. When purchasing the AP-12.5Y, you get: two calibrated sensors: THB S and THB W, two weighing pans: standard, and for balance test and calibration, two pumps: a single-channel pump and a four-channel pump The ergonomic design of the AP-12.5Y makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. When calibrating a multichannel pipette, a four-channel pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration. After emptying a 12-channel pipette, the AP-12.5Y checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports. The AP-12.5Y monitors the ambient conditions using calibrated sensors: THB S (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment). The AP-12.5Y can calibrate not only 12-channel pipettes, but also single-channel pipettes.

€26,933.00 ex VAT
Poland
balances, pipettes calibration, pipettes
Radwag XA 21.5Y.M.A.P Microbalance-cover
Radwag XA 21.5Y.M.A.P Microbalance

Do you need a balance that not only determines weight with impressive accuracy, but also performs a  (more)digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of balances: Digital Weighing Auditor Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the balance will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – An Innovative Way for the Balance to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the balance on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. Automatic Leveling of the Balance ReflexLEVEL System Instead of manually leveling your scale - level it automatically. The ReflexLEVEL System saves you time and gives you maximum precision in your measurements. Smart Min Weight The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold. Ionizer Do you have an electrostatic sample that cannot be weighed? The ionizer will neutralize its electrostatic charge. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. - Full data security - Electronic signatures - Validations - Electronic records - Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. Two-point adjustment Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€16,236.00 ex VAT
Poland
filtration supplies, balances, pipettes calibration, pipettes, microbalances, filter weighing
Labconco ScrubAir Pipette Washer Dryer Glaswaschgerät/-trockner-cover
Labconco ScrubAir Pipette Washer Dryer Glaswaschgerät/-trockner

Manufacturer: Labconco  Model: ScrubAir Description: Compared to traditional siphon washing/rinsing  (more)and oven drying, the ScrubAir uses less water, time and money. It only takes 3 1/4 hours to wash, rinse and dry up to 60 pipettes. The ScrubAir standard wash cycle uses only 12.5 litres of tap water or pure water compared to 600 litres for the siphon method. The three cycle programmes are pre-set at the factory but can be changed by the user and the start time can be delayed by up to 8 hours. The LCD display shows both the cycle segment and the total time remaining. The models have a brushed 304 stainless steel or powder coated steel housing, a pipette holder and a splash guard. Key features: - Automatic, easy to use and less handling of glassware than conventional methods - Fast, thorough cleaning of pipettes inside and out by percolation - Programmable cycle settings and user-defined start delay - Stainless steel housing and pipette holder ensure stability and durability Technical data Water consumption: 1.33 Outer width (in): 15 External height (in): 37.75 Outer depth (in): 18.5 Power supply (VAC): 230 Power supply (Hz): 50/60 Washing temperature (° F): 120 Wash temperature (° C): 49 Inlet connection: 3/8" O.D. Outlet connections: 1.25" Description: Pipette washer, 230V, for 12 to 60 pipettes The device/system offered here has been tested and is fully functional and ready for use.

€1,700.00 ex VAT
€2,023.00 incl. VAT if applicable
Germany
pipettes
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]