Agilent Series 1100 HPLC System

LabMakelaar Benelux B.V.
item image

Description by the supplier

System contains:


Solvent tray

Vacuum degasser

Binary pump

Autosampler

Thermostatted colomn compartment

Variable wavelength detector


Vacuum degasser:

The Agilent 1100 HPLC Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance.


Binary pump:

Flow Precision: <0.3 % RSD (typically <0.15 % RSD)

Flow Range: Setpoints from 0.001 to 5.0 ml/min,  in 0.001 ml/min increments

Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi)

Pulsation: <2 % amplitude (typically <1 %) at 1 ml/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi)

Compressibility compensation: User selectable, based on mobile phase compressibility

Delay volume: 180 – 480 µl (600-900 µl with mixer) dependent on back pressure

Recommended pH range: 1.0 – 12.5. Solvents with pH <2.3 should not contain acids which attack steel


Well-plate autosampler:

Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Injection range: 0.01 – 8 µl in 0.01 µl increments

Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl

Sample viscosity range: 0.2 – 5 cp

Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray

Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl

Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm

Mobile phase: Water/Acetonitrile = 85/15

Column Flow rate: 13 µl/min

Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port


Thermostatted colomn compartment:

Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min

Temperature stability: ± 0.15 °C

Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration)

Column capacity: Three 30 cm

Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C

Dead volume: 3 µl 

Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module

Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.


Variable wavelength detector:

Detection type: Double beam photometer

Light source: Deuterium lamp

Wavelength range: 190 – 600 nm

Wavelength accuracy: ± 1 nm

Bandwidth: 6.5 nm

Linearity:> 2AU (5%) upper limit

Flow cell standard: 14 µl volume, 10 mm cell path length, 40 bar

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: 2 Solvent cabinets 2 Capillary pumps 1 Well-plate samplers 2 Autosampler thermostat (more)s 1 Thermostatted colomn compartment 1 Diode array detector 1 Handheld control module Vacuum degasser cel is missing in the vacuum degasser Capillary pump: Settable column flow range: 0.01 – 20 µl/min Recommended column flow range: 1 – 20 µl/min Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) Optimum composition range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting Delay volume: Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Pressure range: 20 to 400 bar (5880 psi) system pressure Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. Well-plate sampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Autosampler thermostat: Temperature range: setable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient temperatures < 25 °C and humidity < 50%: – 1°C to + 4 °C at a setpoint of 4 °C Temperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%: – 1°C to + 5 °C at a setpoint of 4 °C Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. Handheld control module: The control module provides complete local control and monitoring of a single module or an entire Agilent series system. There is no data evaluation in the control module. The control module allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses.

€9,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
NEW! Eppendorf CryoCube F101h F101 ULT Ultra Freezer Tiefkühlschrank 101L -86C-cover
NEW! Eppendorf CryoCube F101h F101 ULT Ultra Freezer Tiefkühlschrank 101L -86C

Hersteller: Eppendorf Modell: CryoCube™ F101h ULT Beschreibung: Der F101h Ultratiefkühlschrank (ULT) (more) eignet sich ideal für die Lagerung kleinerer Probenansammlungen unter dem Labortisch. Durch die zuverlässige -80 °C-Temperatur in einem kompakten Design bietet der CryoCube™ F101h eine langlebige und sichere Probenlagerung. Kernmerkmale: • Vakuum-Dämmplatten ermöglichen eine höhere interne Kapazität wie herkömmliche Tiefkühlschränke bei gleicher Stellfläche. • Die abgedichteten und isolierten Innentüren haben 2 separate Fächer, die bei der Entnahme von Proben den Kaltluftverlust minimieren. • Leicht ablesbares LED-Bedienfeld und Alarmstatus • Die spezielle Vakuumentlüftung mit ergonomisch positioniertem Kolben ermöglicht den Sofortzugriff auf das Tiefkühlgerät. • Außenwand aus pulverbeschichtetem Edelstahl • Dank spezieller Niedertemperatur-Dichtungen an der Außentür bleiben die Dichtungen auch bei –86 °C flexibel   und verhindern die Eisbildung beim Zugriff auf Proben Technische Daten: Kapazität (metrisch):          101 l Schrankmaterial:        Edelstahl Abmessungen (T x B x H) innen:  33 x 48 x 64 cm Abmessungen (L x B x H) außen:  56,6 x 90 x 83 cm Stellfläche (metrisch):   90 x 56,6 cm Notversorgungssysteme:   LN2 (werkseitig installiert) Frequenz:    50 Hz Stromstärke:    5 A Spannung:    230 V Kompressor:    2-stufig Gewicht (metrisch):   123 kg Temperaturbereich:   -50 °C° bis -86 °C° Isolierung:    Vakuum, Polyurethanschaum Lieferumfang: - Neugerät CryoCube™ F101h ULT - Stromkabel - Bedienungsanleitung als PDF via E-Mail Der Tiefkühlschrank befindet sich in einem absoluten Top Zustand und wurde 100%  auf Funktion geprüft.

€5,000.00 ex VAT
€5,950.00 incl. VAT if applicable
Germany
general laboratory equipment other