Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Balances Accessories

Radwag THB-R-cover
Radwag THB-R

INTENDED USE THB-R PC software is designed to monitor and register indoor ambient conditions, wherei (more)n the said monitoring is based on data collected by measuring devices of Radwag production. Two THB software versions are offered: THB-R-Single – intended for integration with THB-3/2 ambient conditions module, THB-R-Multi – intended for integration with THB-R ambient conditions recorder. Overview THB-R PC software is responsible for establishing communication with measuring devices. It operates as a user interface intended for collected data presentation, archiving, reporting and for carrying out measuring devices setup. The software carries out constant readout of air temperature, relative air humidity, atmospheric pressure and vibrations. Additionally it calculates air density. Current metrological parameters values are demonstrated in a form of a time diagram, wherein the last 5 minutes are presented. The measurements may also be archived in a local database, MS Access format. The record takes place in a specified time interval. Database files are formed using one of four user-defined methods: daily, weekly, monthly, combination of all. THB-R-Multi version of the PC software enables record of measurements collected by THB-R Ambient Conditions Recorder. The stored data may be previewed and printed in a form of reports and diagrams. THB-R installation package comprises THB-Network Viewer allowing local network users to preview current indications of measuring units. Cooperation with measuring devices The software cooperates with measuring devices such as ambient conditions modules of RADWAG production. The modules are intended for operation with THB-R-Single or THB-R-Multi software version. Depending on the used device, communication between the software and the device may be established via RS 232 or USB interface. The latest software versions: THB-R-Single: v. 4.0.2 THB-R-Multi: v. 5.2.0.3

€448.00 ex VAT
Poland
general laboratory equipment other, analytical balances, analytical balances accessories, balances, balances accessories, ultra microbalances, ultra & microbalances accessories, scales, microbalances accessories, mass comparators accessories, mass comparators
Radwag Stent Weighing Kit-cover
Radwag Stent Weighing Kit

A stent is a type of prosthesis that is placed inside a blood vessel to restore its patency. Stent D (more)ozens of lives are saved thanks to it. Its shape, size, and weight must be matched to the blood vessel. In addition, the stent application site requires attention to sterility. These properties necessitate the use of balances with the highest resolution for the inspection of stents. The stent weighing kit has been designed to ensure that such a delicate sample, a stent, is weighed with the greatest precision possible, yet in an easy and ergonomic manner. The said precision is obtained thanks to the XA 5Y.M.A.S. microbalances, and ergonomics due to the specially designed weighing pan and additional draft shields. The weighing pans that are part of the kit allow for weighing stents of different sizes, including 5.5 × 140 mm, 6 × 60 mm, 8 × 40 mm, 8 × 40 mm, 19 × 10 mm, and 1.6 × 19 mm. Thanks to the well-thought-out design of the kit and its applicators, the user places the stent on a special tray, which increases ergonomics and eliminates cross-contamination. The stent weighing kit includes 7 items: draft shield base, 2 draft shields, 2 fork-shaped stent weighing pans: for small (1) and large (1) stents, 2 stent applicators: for small (1) and large (1) stents. Due to the different shapes and sizes of stents, two types of weighing pans, dedicated covers, and size-appropriate applicators come standard with the kit. The RADWAG-manufactured microbalance is a versatile solution. Therefore, it can be operated by a right- or left-handed person. The overall design of the kit, i.e. a fork-shaped weighing pan with an additional draft shield, has eliminated the difficulties associated with weighing of a small-weight sample of a relatively large volume such as stent. With this, the stent weighing results are obtained with an accuracy equal to that of the balance. The kit is intended for all load capacities of the XA 5Y.M.A.S. series balances.

€1,950.00 ex VAT
Poland
ultra & microbalances accessories, ultra microbalances, balances, balances accessories, microbalances accessories, stent weighing
Radwag PA-04/H Automatic Feeder-cover
Radwag PA-04/H Automatic Feeder

The automatic feeder is dedicated for automatic dispensing of small objects onto the weighing pan of (more) RADWAG-manufactured balance to which it is connected. The feeder ensures regular feeding of the elements in accordance with determined time intervals. Operation and Compatibility The PA-04/H feeder cooperates with XA 4Y and AS 3Y analytical balances and PS 3Y precision balances. Both the feeder and the balance are automated devices. The balance carries out analysis of dosed elements and sends signal to the feeder to dispense subsequent element. The feeder features diodes, signalling its operation, and keypad allowing to control the process. Automatic feeder is equipped with function of automatic emptying of the storage bin. Vibrating Feeder Cylindrical vibrating feeder with storage bin enables safe and precise dosing of elements. The storage bin has a conical and stepped shape and is continuously welded. The stainless steel surface of adequate roughness reduces elements grating during dosing process. Variety of Applications The feeder is appropriate for dosing pills of diameter ranging from 3 to 25 mm, round and oblong, as well as details of similar shapes and dimensions Design The device is equipped with powder-coated steel housing and stainless steel cover. The storage bin features transparent lid that allows verifying quantity of remaining elements. Compatible with scales: All analytycal XA 5Y.A All analytycal XA 5Y Microbalances: - XA 21.5Y.M.A - XA 21/52.5Y.M.A - XA 52.5Y.M.A - XA 53.5Y.M.A Microbalances: - XA 21.5Y.M - XA 21/52.5Y.M - XA 52.5Y.M - XA 53.5Y.M Note! To make the feeder work, simply buy the PT0453 cable, which is not part of the set.

€6,464.00 ex VAT
Poland
microbalances accessories, analytical balances accessories, analytical balances, ultra & microbalances accessories, scales, microbalances, general laboratory equipment other, balances accessories, balances
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y-cover
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y

XA17 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 17 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

Poland
analytical balances, pipettes, balances accessories, pipettes calibration, scales, ultra & microbalances accessories, ultra microbalances, balances, analytical balances accessories, microbalances, microbalances accessories
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml-cover
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml

XA11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA microbalance. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 11 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
ultra microbalances, pipettes, pipettes calibration, scales, ultra & microbalances accessories, microbalances accessories, analytical balances, analytical balances accessories, balances, balances accessories, microbalances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]