XA17 pipette calibration adapter enables calibration and/or verification of piston pipettes by means of a gravimetric method using the XA analytical balence.
Set content:
base
weighing pan
weighing vessel
evaporation ring
glass chamber with an opening for dosing
Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped.
An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts.
Vessel capacity: 17 ml
Adapters for Pipettes Calibration
Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object.
Nominal volume
of apparatus under test
V
Resolution
(d) mg
Repeatability
(s)3mg
Recommended balance
Microbalances
Analytical balances
0,5 µl ≤ V < 20 µl
0,001c
0,01d
0,006c,
e 0,03d
MYA 21.5Y
XA 6/21.5Y.M.A
XA 6/21.5Y.M
XA 21.5Y.M.A
XA 21.5Y.M
XA 21/52.5Y.M.A
XA 21/52.5Y.M
XA 53.5Y.M.A
XA 53.5Y.M
20 µl ≤ V < 200 µl
0,01
0,025
XA 52.5Y
XA 110.5Y
XA 82/220.5Y.A
XA 82/220.5Y
XA 120/250.5Y.A
XA 120/250.5Y
200 µl ≤ V ≤ 10 ml
0,1
0,2
Adapter for pipette calibration
MY 11
XA 11
XA 11
XA 11
XA 11
XA 17
XA 17
XA 17
XA 100
XA 17
XA 100
Maximum vessel capacity
11 ml
11 ml
11 ml
11 ml
11 ml
17 ml
17 ml
17 ml
100 ml
17 ml
100 ml
Weighing vessel mass
~ 10 g
~ 10 g
~ 10 g
~ 10 g
~ 10 g
~ 11 g
~ 11 g
~ 11 g
~ 65 g
~ 11 g
~ 65 g
a
The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table.
c
Single-channel balance.
d
Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object.
e
For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object.
table {font-size: 12px}
td {padding:10px; }
tr {text-align:center;}
@media (max-width: 800px) {
table {font-size: 9px}
td {padding: 1px 1px}
}
QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.
Customer Service
Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.
We are available to assist you Mon-Fri, 10am - 5pm CET.