Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
MA 200/1.5Y.WH Moisture Analyzer
Supplier
Radwag
Location
Radom - Poland
Price
€7,228.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag MA 200/1.5Y.WH Moisture Analyzer

Radwag€7,228.00 (ex VAT)
item image

Description by the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?


If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:


It Dries in 4 Ways


The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.


The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.


The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.


You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.


The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.


What Drying Temperature Should I Set?


The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.


The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C.


How Do I Finish the Drying? In 4 Ways


The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.


Automatic mode

You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.


Manual mode

You terminate the measurement yourself by pressing the STOP button.


Time-defined mode

The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!


User-defined mode

When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.


Digital Weighing Auditor


Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.


10-Inch Display


Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.


Uncompromising User Verification


For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.


Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User


The light colour will tell you about status, process results, procedures, or alerts.


Hotspot


Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.


RFID


ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.


Live Note – Note Down Your Conclusions


It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.


Handy Library


This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.


Widgets


Prepared to display what you need most at any given moment.


21 CFR Part 11


Do you work in the pharmaceutical industry? Do you need a digital signature?


We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.


Full data security


Electronic signatures


Validations


Electronic records


Audit trails


Modbus TCP/IP


is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.


A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.


* RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details
FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag F2 Mass Standard - Flat Polygonal Sheet - 500 mg-cover
Radwag F2 Mass Standard - Flat Polygonal Sheet - 500 mg

F2-class mass standards represent an impressive level of precision in mass measurement. Classified a (more)s metrology grade F2, they are recognized as top-quality tools suited for advanced applications where precision is a key element. F2 mass standard: flat polygonal sheet Nominal value: 500 mg Material: nickel silver F2 Class Mass Standards – Key Features Exceptional Measurement Precision - F2 class mass standards feature excellent measurement precision achieved through stringent standards for allowable deviation from actual weight. Stability under Dynamic Conditions - An important feature of F2-class mass standards is their ability to maintain measurement stability even under dynamic measurement conditions. They are designed to cope with a variety of factors that affect measurement precision. Calibration at the Highest Level - The calibration process of F2-class mass standards adheres to the most stringent norms and standards. This makes the standards of this class recognized as tools with the highest degree of accuracy, complying with international requirements. Use of Materials with Outstanding Properties - F2 class mass standards are often constructed from materials with outstanding physical properties. This ensures not only excellent precision, but also exceptional durability. Application 1. Scientific Research at the Highest Level In scientific research, especially in fields that require the utmost precision, such as nuclear physics or astrophysics, F2 class mass standards are indispensable. 2. Metrology Industry In metrology laboratories engaged in testing and maintaining the most advanced measurement standards, F2 class standards are indispensable working tools. 3. High-Precision Testing Laboratories In laboratories specializing in research requiring the highest precision, such as forensic laboratories and materials testing, F2 class mass standards are essential. 4. Aerospace Industry In the precision mass measurements required in the aerospace industry, F2 class standards provide reliability and excellence. F2 class mass standards are the symbol of the highest precision in the field of mass measurement. Their use is crucial in the most advanced fields of science, industry and research.

€18.00 ex VAT
Poland
mass standards
Radwag WLC 6/A2.IO Precision Balance-cover
Radwag WLC 6/A2.IO Precision Balance

Precision of WLC balances Fast, accurate and repeatable weight determination. Energy-efficient elect (more)ronics and display, combined with an internal rechargeable battery, are the perfect duo to allow you to work without access to mains power. Precision not just in the name When we designed this balance, we took care of the smallest details – both those you can’t see, hidden in the solid housing, and those you can touch. This balance is the result of a combination of our experience and true precision. The power of steel The use of stainless steel for the pan guarantees you a long life for the balance. It is not afraid of contact with moist objects or accidental splashes. It has been with us for years, and will stay for a long time to come The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient. Internal power The internal rechargeable battery combined with the energy-saving display and electronics allow many hours of operation without mains power. Time counts The balance is equipped with a real-time clock that provides accurate time measurement in a way that is independent of external power supply. There is potential Printer, computer, flash drive or additional display – you can easily connect them thanks to the fact that the balance is equipped with interfaces: 2 x RS232, USB type A and USB type B. Optionally, the balance can be equipped with 4 IN and 4 OUT. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. Good ALIBI The ALIBI memory used in the terminal allows for safe storage of weighing records without the possibility of unauthorized interference. A single measurement remains in the ALIBI memory up to a preset limit number of days of storage, counting from the date it was taken. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€440.00 ex VAT
Poland
balances, precision balances
Radwag MA 110.X7.IC.A.NS Moisture Analyzer-cover
Radwag MA 110.X7.IC.A.NS Moisture Analyzer

MA X7.IC.A moisture analyzers are hi-tech measuring instruments intended for quick determination of  (more)relative moisture content, dry mass content and other parameters in samples of different substances. MA.X7.IC.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X7.IC.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X7 Series moisture analyzers: Automatic opening and closing of the drying chamber 7” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X7.IC.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X7 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€2,098.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 50.5Y.WH Moisture Analyzer-cover
Radwag MA 50.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,390.00 ex VAT
Poland
moisture analysers, balances
People are watching right now:
Hoefer HE33B Mini Horizontal Agarose Electrophoresis Unit-cover
Hoefer HE33B Mini Horizontal Agarose Electrophoresis Unit

Hoefer HE33B Mini Horizontal Agarose Electrophoresis Unit Gel Dimensions (W x L) 7 x 10 cm Maximum P (more)ower Settings 500 V for (5 min or less), 500 mA, 15 W Maximum Buffer Volume 250 ml Features - Fast separations—run a 7 x 10 cm gel in as little as 5 minutes - UV transparent running tray—allows the user to image the gel without risk of damage due to handling - Variety of comb sizes—enables customization of sample throughput to fit your laboratory's requirements - Adjustable comb height—complete control over well depth The Hoefer HE33B Mini Horizontal Agarose Electrophoresis Unit is an efficient and compact system specifically designed for rapid DNA separation in agarose gels. Ideal for labs requiring quick results, this unit can run a 7 x 10 cm gel in as little as five minutes, allowing for fast DNA fragment analysis. With a UV-transparent running tray, the HE33B enables users to image the gel directly without handling, minimizing the risk of damage and preserving sample integrity. Equipped with a versatile array of comb sizes and adjustable comb height, this unit allows for precise control over well depth and sample throughput, offering customizable options to fit various lab requirements. To achieve passive cooling, the clear molded base can be pre-filled with 50% ethylene glycol coolant, sealed, and frozen or chilled before use, ensuring consistent performance. Designed for durability, the HE33B operates smoothly within standard lab conditions, handling temperatures up to 50°C and humidity levels up to 80%, with power settings of up to 500 V for brief runs. Please note, the dropdown menu allows selection of a complete package, which includes: - Buffer Chamber Assembly - Safety Lid with High Voltage Leads - Running Tray - Casting Tray - Foam Gaskets, 4 pcs - Bubble Level - 1.5 mm thick, 8-well comb - Comb Back INCLUDED: The Hoefer HE33B Mini Horizontal Agarose Electrophoresis Unit includes: - Buffer Chamber Assembly - Safety Lid with High Voltage Leads - Running Tray - Casting Tray - Foam Gaskets, 4 pcs - Bubble Level - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$423.00 ex VAT
United States
electrophoresis
Memmert UN30 Natural Convection Oven 32L, 115V-cover
Memmert UN30 Natural Convection Oven 32L, 115V

Memmert UN30 Natural Convection Oven 32L, 115V Temperature Range Ambient +5°C to 300°C Convection T (more)ype Natural Convection Chamber Volume 32L Features - 32L chamber volume accommodates various sample sizes, enhancing lab versatility - Precise temperature control from +5°C above ambient to 300°C for sensitive applications - Ergonomic PID controller with high-definition TFT display for intuitive adjustments - Durable stainless steel interior and exterior, corrosion-resistant for rigorous use - Natural convection ensures uniform heat distribution for delicate samples - Pre-heated fresh air admixture with adjustable air flap for temperature uniformity - Adaptive settings include programmable temperature, timer, and setpoint wait for workflow optimization - AtmoCONTROL software for data logging and remote monitoring via Ethernet - Easy-to-clean stainless steel interior with reinforced ribbing, ideal for frequent use The Memmert UN30 Natural Convection Oven 32L, 115V delivers precise temperature control from Ambient +5°C to 300°C, making it ideal for a variety of sensitive applications. Featuring an ergonomic digital PID controller with a high-definition TFT display, this oven offers intuitive settings and rapid access to temperature adjustments. Built for rigorous lab environments, its durable stainless steel construction resists corrosion, while the natural convection system ensures even, consistent heating distribution across all samples. Fully adjustable safety controls, including a built-in overtemperature monitor, provide added protection and peace of mind. With an easy-to-clean interior and robust stainless-steel shelving, the UN55 maximizes efficiency in daily operations, delivering reliable performance for years to come. INCLUDED: The Memmert UN30 Natural Convection Oven 32L, 115V includes: - 1 x Stainless Steel Grid - Tilt Protection Wall Bracket - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$1,879.00 ex VAT
United States
heating & cooling, ovens, furnaces
Ohaus EX225D/AD Explorer Semi-Micro Analytical Balance, 120/220g, 0.00001/0.0001g-cover
Ohaus EX225D/AD Explorer Semi-Micro Analytical Balance, 120/220g, 0.00001/0.0001g

Ohaus EX225D/AD Explorer Semi-Micro Analytical Balance For lab work and research that demand precisi (more)on up to five decimal places, the margin for error is nonexistent. The Explorer series of semi-micro balances is engineered with the latest technology to ensure exactness in your specific weighing results. Labs seeking a combination of precision and innovative technology will find both in our Explorer semi-micro balances.Designed for peak performance, these balances offer readability up to 0.01mg and capacities reaching 220g. The integrated AutoCal™ Internal Calibration system guarantees accuracy in applications that need high precision.Featuring a vibrant touchscreen display, the user experience is significantly enhanced. The balance also includes touchless sensors, automatic draftshield doors (included in select models), and an ionizer to safeguard the credibility of your results.To further enrich your weighing process, the balance is outfitted with SmarText™ 2.0 software, icon-based navigation, a 99-item library, 6 user profiles, and an indication for below-minimum sample weight. All these features come together to deliver an efficient, yet straightforward weighing experience.INCLUDED: The Ohaus EX225D/AD Explorer Semi-Micro Analytical Balance includes: - Power Cord - 2 Year Manufacturer's Warranty

$8,130.00 ex VAT
United States
electron microscopes, scales, scanning electron microscopes, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]