Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Spectroscopy

Spectroscopy is one of the most used tools to explore properties of matter and is an umbrella term for different techniques such as infrared spectroscopy, visible light spectroscopy, UV-light spectroscopy, X-ray spectroscopy, Raman spectroscopy and nuclear magnetic resonance. Spectroscopy instruments can be stand-alone devices, but are increasingly integrated as part of other equipment, for example in combination wit (more)h confocal microscopy.

Beckman DU-65 UV/Vis Scanning Spectrophotometer 200-900nm Wavelength Scan-cover
Beckman DU-65 UV/Vis Scanning Spectrophotometer 200-900nm Wavelength Scan

Manufacturer: Beckman Model: DU-65 UV/Vis Spectrophotometer P/N: 120651 S/N: 4310288 Description: Be (more)ckman Coulter DU-65 uv-vis spectrophotometer. The Beckman DU-65 is an  instrument that combines optimized wavelength scanning with step-programmable capabilities and brings self contained versatility and productivity to the laboratory. The  basic operation can be mastered in seconds with time saving features like  storage of calibrations and auto-scaling of scans. With its Plug in Soft-Pacs, repeated  analyses can be produced at the touch of a button with a variety of functions such as linear and non-linear calibration curves, wavelength scans, kinetic measurements,  and gel-scans. These modules are available for various applications such as protein assays, DNA purity, tablet dissolution rates, and performance validation. No need of software or anything else - very comfortable wavelength scans with  transmission and absorbance with the printer on top! Specifications: Operating Principle: Double beam spectrometer for the UV/VIS region, with  microcomputer electronics, keyboard entry and vacuum fluorescence display.Monochromator: Holographic concave grating with 1053 lines/mm.Radiation: Prealigned Deuterium and Tungsten halogen lamps with automatic lamp  switching.Wavelength: 200 nm – 900 nm.Scanning Speed : 500 or 750 nm/ min selectableStray Radiation: Measured with a 2 sec response time< 0.03 %T at 220 nm< 0.02 %T at 340 nm, 370 nm.Wavelength Accuracy: +- 0.3 nm at Deuterium peak 656.1 nm.Reproducibility: +- 0.1 nm.Spectral Slit Width: 2 nm.Photometric Accuracy: +- 0.005 A at 1 A (measured with NBS 930 filters).Reproducibility: +- 0.002 A at 1A.Range: -3 to +3 A.Stability: < 0.0003 A/h (at 500 nm, 1 sec response time, after warmup).Baseline Stability: +- 0.001 A (200-900 nm at 0 A, 2 sec response time, 240  nm/min scan speed.Noise: < 0.0003 A (at 0 A, 500 nm, 2 sec response time) All Intelligence in the Instrument with direct keyboard input. . No need for  external PC, Software or anything else - very comfortable wavelength scans with  transmission and absorbance with the printer on top giving you direct print-outs  of any made scan. SEE PHOTO Items delivered: - Beckman DU-65 UV/Vis Spectrometer- Epson FX-850 (new ink ribbon installed)- Performance Validation Soft-Pac Module (596716)- Memory Pac Module (598286)- Quant II Soft-Pac Module (598288- Beckman Instruction Manuals German & English- Connection and Power Cords- Spare Lamp The spectrometer DU-65 is in good cosmetic condition and 100% functional tested.  Passes selftests and runs wavelength scans very smooth.

€1,300.00 ex VAT
€1,547.00 incl. VAT if applicable
Germany
spectrophotometers uv vis & fluor
Bruker Autoflex Speed MALDI-TOF Mass Spectrometer-cover
Bruker Autoflex Speed MALDI-TOF Mass Spectrometer

Innovative MALDI-TOF and TOF/TOF technology designed and optimized to be easy-to-use; robust systems (more) for both traditional MALDI applications (reliable and detailed protein/peptide characterization, and polymer analysis) as well as cutting edge work (high resolution MALDI Tissue Imaging, glycan analysis or high-throughput MALDI Biotyper microbial identification). The new autoflex speed incorporates a number of key features which enhance its capabilities and value including: Enhanced Speed with a 2 kHz (kiloHertz) proprietary smartbeam-II solid-state laser and electronics for high throughput applications including LC-MALDI, MALDI Imaging, and high-throughput microbiology ID Unique FAST-SRM mode provides single reaction monitoring capabilities for imaging of drugs and metabolites in tissue Expanded High-Resolution Mass Range for analysis of polymers and Top-Down, intact protein sequencing for long sequence readouts FlashDetector technology to increase resolution and prevent signal saturation for complex samples Self-cleaning Ion Source cleans the instrument source in minutes to improve system up-time and with minimal operator maintenance Optimized Software packages for numerous applications e.g. Protein-, Peptide-, Polymer-Analyses, and MALDI Imaging, clinical research methods and the MALDI Biotyper IVD-CE workflow. The most flexible autoflex instruments are available in linear only mode, high resolution reflectron mode and the latest TOF/TOF technology (LIFT) which enables the use of various MS/MS techniques (e.g. LID, high energy CID) for fast and sensitive MS/MS experiments. Including PC and several sample plates

€69,999.00 ex VAT
Netherlands
mass spectrometers, nmr spectrometers
Avantes HortiSpec+ Spectrometer System-cover
Avantes HortiSpec+ Spectrometer System

HortiSpec+ equipped with a NR Lite2 Net Radiometer probe. The HortiSpec was developed to measure the (more) light intensity and spectral distribution in the visible and NIR range inside greenhouses. Plant growth and the photo synthesis depends very much on light intensisty and spectral distribution of the light intensity. The light intensity can be measured with the HortiSpec in Photons or other parameter, specific for the Horticulture. NR Lite2 is designed for routine measurement of net radiation which is the balance between incoming and outgoing radiation under outdoor conditions. The design of the NR Lite2 is unique. The double-sided detector has black conical absorbers with an anti-stick weather resistant protective coating. In contrast to other sensor designs, NR Lite2 requires no fragile plastic domes. This results in a virtually maintenance free design. The vertical stick prevents birds from affecting the output signal. Spectrometer: AvaSpec – 2048, CCD linear array 2048 pixels Grating VA, wavelength range (300 – 1100 nm) 200 µm slit, Detector collection lens, Order sorting coating Data communicaton: USB version 2.0, 480 mbps Aperture: Diffusor, diameter 3.9 mm Software: HortiSpec Irradiance software Measurement units: photon flux in µmol/s.m² Parameters: Lux, PAR, Blue, Yellow/Green, Red, Far red Specifications NR Lite2: Spectral range (overall): 0.2 to 100 µm Sensitivity: 10 µV/W/m² Response time: < 20 s Operational temperature range: -30 °C to +70 °C

€3,950.00 ex VAT
Netherlands
nmr spectrometers
Bruker LC-NMR-MS Interface-cover
Bruker LC-NMR-MS Interface

The LC-NMR-MS Interface is designed to sit between an HPLC system, an NMR spectroscopy probehead and (more) an MS unit. It would normally be mounted on top of the MS table immediately in front of the MS input connector. The BNMI-HP consists of 3 medium pressure (> 60Bar) syringe pumps, a 1:20 splitter, an 8-Port valve, 3 mixing chambers (T-Pieces) and associated control and interface electronics. The flow of the HPLC separations to the MS unit can be modified by pumping additional solvent from the syringe pumps. This improves the MS peak detection and shortens the time needed for the split separation to reach the MS. Separations can also be stored as a result of an MS peak detection as well as through UV absorption peak detection. The splitter splits the fluid flow from the HPLC in a 1:20 ratio. i.e. ca. 5% of the fluid is directed to the MS and the remainder to either the NMR probehead for immediate analysis or to the BPSU36 storage cassette for storage and later analysis.  The fluid directed to the MS is mixed in the mixing chamber (T-Piece) with the solvent pumped from the syringe pumps. The two left hand syringe pumps pump alternatively to guarantee a constant ’makeup’ flow. The 3rd pump at the right hand side is used to pump a calibration fluid into the flow path to allow the MS to be calibrated (or simply synchronized) at the start and end of each measurement cycle. The 8-Port valve is used to direct the fluid flow. Control of the BNMI Unit is performed using the HyStar program via an ethernet interface. Commands received from HyStar are interpreted in the BNMI Control Board. The control board then sets up the BNMI unit accordingly e.g.: Starts the pumps, changes the flow rate, turns the 8-Port valve. The splitter has a fixed mechanical function and cannot be controlled or adjusted. It simply accepts a fluid flow and splits it into 2 paths in a 1:20 ratio. However, other split ratios are available (for example 1:100 may be preferred if you have very high sample concentrations).

€1,499.00 ex VAT
Netherlands
nmr spectrometers
Waters Acquity Xevo TQ Massa Spectrometer System-cover
Waters Acquity Xevo TQ Massa Spectrometer System

The Waters Xevo TQ Mass Spectrometer is an advanced, bench top, tandem quadrupole mass spectrometer  (more)designed for ultra high performance LC/MS/MS applications. Unlike conventional tandem quadrupole mass spectrometers, the Xevo TQ MS utilizes unique T-Wave and ScanWave enabled collision cell technology to provide a highly flexible analytical tool capable of supporting both quantitative and qualitative studies on a single MS platform. The Xevo TQ MS is a robust platform for quantititive LC/MS/MS, featuring high speed MRM (Multiple Reaction Monitoring), with enhanced full scan spectral acquisition modes providing additional qualitative LC/MS/MS capibilities. The system incoporates IntelliStart Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to all levels of operator. Acquisition modes: Full scan MS Product ion scan (ScanWave enhanced) Precursor ion scan Constant neutral loss Selected ion recording (SIR) Multiple reaction monitoring (MRM) Survey scan modes: Full scan MS triggered product ion scan Precursor ion scan triggered product ion scan Constant neutral loss triggered product ion scan Quan Qual mode: MRM triggered ScanWave enhanced product ion spectral acquisition Mass range: 2 to 2048 m/z Scan speed: Up to 10000 Da/s Examples of achievable acquisition rates: 10 scans per second (100 to 1000 m/z) 20 scans per second (50 to 500 m/z) Mass stability: Mass drift is less than 0.1 amu over a 24 h period Linearity of response: The linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from limit detection

€54,999.00 ex VAT
Netherlands
nmr spectrometers
Perkin Elmer 343 Polarimeter-cover
Perkin Elmer 343 Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeters, polarimeter
Perkin Elmer Model 343 S Polarimeter-cover
Perkin Elmer Model 343 S Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeters, polarimeter
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]