Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Flow cytometers

Flow cytometers are instruments that pass cells or particles through a channel and rely on optical techniques and/or imaging to analyse their physicochemical properties. They can be used to look for specific markers and for fully-automated screening or to perform validation experiments for many samples. Flow cytometers can also be used to sort cells that are labelled with fluorescent proteins or specific dyes.

Beckman Coulter CytoFLEX Flow Cytometer incl. Computer & Dongle (2017)-cover
Beckman Coulter CytoFLEX Flow Cytometer incl. Computer & Dongle (2017)

Manufacturer: Beckman Coulter Model: CytoFLEX V0-B3-R2 Description: The device has a capacity of 15  (more)parameters, including 13 for fluorescence detection. The fully activated device has five channels of 405 nm (violet) laser, five channels of 488 nm (blue) laser and three channels of 638 nm (red) laser. Laser specifications: Violet 405 nm 80 mW Blue 488 nm 50 mW Red 638 nm 50 mW Flow cell: Permanently integrated optics and quartz flow cell with >1.3 numerical aperture. Dimensions of the flow cell: 430 μm x 180 μm inner diameter Forward scatter detection: Proprietary Homodyne FSC sensor system with silicon photodiodes and built-in 488/8 nm bandpass filter Bandpass filter Contains 13 repositionable filters: 450/45 660/10 (2) 525/40 (2) 690/50 585/42 712/25 610/20 (2) 780/60 (3) Scattering resolution: Blue (488 nm) Side scattering resolution: <300 nm Violet (405 nm) Side scattering resolution (VSSC): 80 nm Polystyrene particles The scattering performance is optimized for the resolution of human lymphocytes, monocytes and granulocytes as well as nanoparticles. Fluorescence resolution: The CytoFLEX flow cytometer is capable of achieving an rCV of 3%, with particles achieving an rCV of <3% to verify alignment. Sample flow rates: Fixed flow rates: 10, 30 and 60 μL/min User-defined flow rate control mode from 10 to 240 μL/min in 1 μL increments. Gravimetric calibration for absolute counts within CytExpert software. Other data: Voltage: 100-240 V Power: 150-250 W Dimensions: 42.5 cm x 42.5 cm x 34 cm Weight: 23.4 kg The device/system offered here has been tested and is fully functional and ready for use.

€33,500.00 ex VAT
€39,865.00 incl. VAT if applicable
Germany
particle counters, flow cytometers
Beckman Coulter Navios EX Flow Cytometer-cover
Beckman Coulter Navios EX Flow Cytometer

Lasers: Blue Solid State: 488 nm, 55 mW, Software Controlled Red Solid State Diode: 638 nm, 50 mW, S (more)oftware Controlled Violet Solid State: 405 nm, 80 mW, Software Controlled Configuration: Nominal 90 µm spatially separated beam spots Flow cell: 430 µm x 180 µm rectangular channel Collection optics: Fixed integrated optics and quartz flow cell design with a numerical aperture of > 1.2 Detector filters: Forward Scatter: 488/20 Blue Laser: 525/40, 575/30, 614/20 , 675/20, 695/30, 755LP Dyes: FITC, PE, ECD, PC5 or PEC5.5, PECy7 Red Laser: 660/20, 725/20, 755 LP Dyes: APC or Alexa Fluor 647, APC-Alexa Fluor 700, APC-Cy7, APC-Alexa Fluor 750 Violet Laser: 450/50, 550/40 Dyes: Pacific Blue, Krome Orange Forward Scatter Detector: Fourier design providing up to 3 measurements of forward angle Side Scatter Detector: High performance photodiode with electronic attenuation Fluorescence Detectors: FL1 – FL6 Fluorescent Detectors Flow rates: Continuous pressure is applied to the sample tube based on user selected flow rates: Low, Medium and High Performance: Carryover: < 0.1%, Dead volume as low as 2 µL when using Beckman Coulter 12 x 75 mm polypropylene tube and adjustable probe Acquisition modes: 32 tube Multi Carousel Loader (MCL), Single tube sampling mode, Automated work list acquisition, Manual work list mode Mixing: The MCL vortexes each tube individually before sample acquisition Barcode reading: Carousel number, tube location, and tube barcode verified to worklist Biosafety: Biohazard contained wash station thoroughly rinses sample probe Throughput: 10000 normal leukocytes is 82 tubes/hour Scatter resolution: Resolves 0.4 micron particles from background noise using Forward Scatter, Maximum detection of up to 40 microns Fluorescence sensitivity: FITC < 107 MESF, PE < 64 MESF, PC5 < 13 MESF Acquisition rate: 25000 events per second, 90% yield Cytometer dimensions (WxHxD): 950 x 610 x 730 mm Cytometer weight: 104 kg Supply cart dimensions (WxHxD): 724 x 298 x 495 mm Supply cart weight: 30 kg Software included but requires a new licence purchase.

€4,950.00 ex VAT
Netherlands
particle counters, flow cytometers
BD Becton Dickinson FACSCanto II Flow Cytometer-cover
BD Becton Dickinson FACSCanto II Flow Cytometer

The FACSCanto II system is an easy-to-use benchtop analyzer that delivers proven performance, accura (more)cy, and high-quality results. The FACSCanto II can be configured with two or three lasers to detect up to eight colors. It features many innovations, including a true fixed alignment flow cell to minimize startup time and improve  reproducibility. The optical system maximizes signal detection and increases sensitivity and resolution for each color in a multicolor assay. These and other capabilities make the BD FACSCanto II ideal for today’s busy clinical lab, providing a high degree of automation and quality control. With optimal reproducibility, the FACSCanto II system reduces hands-on technician time and costs associated with repeat testing. Lasers: 405-nm solid state diode, 30-mW fiber power output 488-nm solid state, 20-mW laser output 633-nm HeNe, 17-mW laser output Laser Configuration: Spatially separated beams with 9 x 65- μm elliptical spots Optical Alignment Procedure: Fixed, no operator alignment required Flow Cell: 180 x 430-μm rectangular quartz flow cell Collection Optics: Optical-gel coupled 1.2 NA lens FSC Resolution: 1.0 μm SSC Resolution: 0.5 μm Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT FSC Detector: Photodiode with 488/10 BP SSC Detector: PMT with 488/10 BP Fluorescence Detectors: 8 PMTs in 4-2-2 configuration Violet Laser Dyes: Pacific Blue, AmCyan (455, 488 nm) Blue Laser Dyes: FITC, PE, PerCP or PerCP-Cy 5.5, PE-Cy 7 (525, 575, 678 or 695, 785 nm) Red Laser Dyes: APC, APC-Cy7 (660, 785 nm) Detector Bands: Violet Laser: 450/50; 502 to 525 nm Blue Laser: 530/30; 585/42; >670; 780/60 nm Red Laser: 660/20; 780/60 nm Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF Max Particle Size: 50 μm Sample Flow Rate: 10 μL/min to 120 μL/min Sample Acquisition Rate: 10,000 events/second, 6 compensated fluorescence parameters and 2 scatter parameters Sample Dead Volume: 30 μL (BD Falcon tubes 12 x 75-mm) Dimensions (DxWxH): Cytometer: 610 x 910 x 640 mm Fluidics cart: 610 x 790 x 640 mm Weight: Cytometer: 145 kg Fluidics cart: 51 kg

€12,500.00 ex VAT
Netherlands
particle counters, flow cytometers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]