Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Flow cytometers

Flow cytometers are instruments that pass cells or particles through a channel and rely on optical techniques and/or imaging to analyse their physicochemical properties. They can be used to look for specific markers and for fully-automated screening or to perform validation experiments for many samples. Flow cytometers can also be used to sort cells that are labelled with fluorescent proteins or specific dyes.

Beckman Coulter CytoFLEX Flow Cytometer incl. Computer & Dongle (2017)-cover
Beckman Coulter CytoFLEX Flow Cytometer incl. Computer & Dongle (2017)

Hersteller: Beckman Coulter Modell: CytoFLEX V0-B3-R2 Beschreibung: Das Gerät verfügt über eine Kapa (more)zität von 15 Parametern, darunter 13 für die Fluoreszenzdetektion. Das vollständig aktivierte Gerät verfügt über fünf Kanäle des Lasers mit 405 nm (Violett), fünf Kanäle des Lasers mit 488 nm (Blau) und drei Kanäle des Lasers mit 638 nm (Rot). Laser Spezifikationen: Violet 405 nm 80 mW Blue 488 nm 50 mW Red 638 nm 50 mW Durchflusszelle: Fest integrierte Optik und Quarzdurchflusszelle mit >1,3 numerischer Apertur. Abmessungen der Durchflusszelle: 430 μm x 180 μm Innendurchmesser Vorwärtsstreuungserkennung: Proprietäres Homodyne-FSC-Sensorsystem mit Silizium-Fotodioden und eingebautem 488/8-nm-Bandpassfilter Bandpassfilter Enthält 13 neu positionierbare Filter: 450/45 660/10 (2) 525/40 (2) 690/50 585/42 712/25 610/20 (2) 780/60 (3) Streuauflösung: Blau (488 nm) Auflösung der Seitenstreuung: <300 nm Violett (405 nm) Seitenstreuungsauflösung (VSSC): 80 nm Polystyrol-Partikel Die Streuleistung ist für die Auflösung von menschlichen Lymphozyten, Monozyten und Granulozyten sowie von Nanopartikeln optimiert. Fluoreszensauflösung: Das CytoFLEX-Durchflusszytometer ist in der Lage, einen rCV von 3 % zu erreichen, wobei die Partikel zur Überprüfung der Ausrichtung einen rCV von <3 % erreichen. Probenflussraten: Feste Durchflussraten: 10, 30 und 60 μL/min Benutzerdefinierter Durchflussratenregelungsmodus von 10 bis 240 μL/min in 1 μL-Schritten. Gravimetrische Kalibrierung für absolute Zählungen innerhalb der CytExpert Software. Sonstige Daten: Spannung: 100-240 V Leistung: 150-250 W Maße: 42.5 cm x 42.5 cm x 34 cm Gewicht: 23,4 kg

€33,500.00 ex VAT
€39,865.00 incl. VAT if applicable
Germany
flow cytometers, particle counters
BD Becton Dickinson FACSCanto II Flow Cytometer-cover
BD Becton Dickinson FACSCanto II Flow Cytometer

The FACSCanto II system is an easy-to-use benchtop analyzer that delivers proven performance, accura (more)cy, and high-quality results. The FACSCanto II can be configured with two or three lasers to detect up to eight colors. It features many innovations, including a true fixed alignment flow cell to minimize startup time and improve  reproducibility. The optical system maximizes signal detection and increases sensitivity and resolution for each color in a multicolor assay. These and other capabilities make the BD FACSCanto II ideal for today’s busy clinical lab, providing a high degree of automation and quality control. With optimal reproducibility, the FACSCanto II system reduces hands-on technician time and costs associated with repeat testing. Lasers: 405-nm solid state diode, 30-mW fiber power output 488-nm solid state, 20-mW laser output 633-nm HeNe, 17-mW laser output Laser Configuration: Spatially separated beams with 9 x 65- μm elliptical spots Optical Alignment Procedure: Fixed, no operator alignment required Flow Cell: 180 x 430-μm rectangular quartz flow cell Collection Optics: Optical-gel coupled 1.2 NA lens FSC Resolution: 1.0 μm SSC Resolution: 0.5 μm Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT FSC Detector: Photodiode with 488/10 BP SSC Detector: PMT with 488/10 BP Fluorescence Detectors: 8 PMTs in 4-2-2 configuration Violet Laser Dyes: Pacific Blue, AmCyan (455, 488 nm) Blue Laser Dyes: FITC, PE, PerCP or PerCP-Cy 5.5, PE-Cy 7 (525, 575, 678 or 695, 785 nm) Red Laser Dyes: APC, APC-Cy7 (660, 785 nm) Detector Bands: Violet Laser: 450/50; 502 to 525 nm Blue Laser: 530/30; 585/42; >670; 780/60 nm Red Laser: 660/20; 780/60 nm Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF Max Particle Size: 50 μm Sample Flow Rate: 10 μL/min to 120 μL/min Sample Acquisition Rate: 10,000 events/second, 6 compensated fluorescence parameters and 2 scatter parameters Sample Dead Volume: 30 μL (BD Falcon tubes 12 x 75-mm) Dimensions (DxWxH): Cytometer: 610 x 910 x 640 mm Fluidics cart: 610 x 790 x 640 mm Weight: Cytometer: 145 kg Fluidics cart: 51 kg

€12,500.00 ex VAT
Netherlands
flow cytometers, particle counters
Beckman Coulter Navios EX Flow Cytometer-cover
Beckman Coulter Navios EX Flow Cytometer

Lasers: Blue Solid State: 488 nm, 55 mW, Software Controlled Red Solid State Diode: 638 nm, 50 mW, S (more)oftware Controlled Violet Solid State: 405 nm, 80 mW, Software Controlled Configuration: Nominal 90 µm spatially separated beam spots Flow cell: 430 µm x 180 µm rectangular channel Collection optics: Fixed integrated optics and quartz flow cell design with a numerical aperture of > 1.2 Detector filters: Forward Scatter: 488/20 Blue Laser: 525/40, 575/30, 614/20 , 675/20, 695/30, 755LP Dyes: FITC, PE, ECD, PC5 or PEC5.5, PECy7 Red Laser: 660/20, 725/20, 755 LP Dyes: APC or Alexa Fluor 647, APC-Alexa Fluor 700, APC-Cy7, APC-Alexa Fluor 750 Violet Laser: 450/50, 550/40 Dyes: Pacific Blue, Krome Orange Forward Scatter Detector: Fourier design providing up to 3 measurements of forward angle Side Scatter Detector: High performance photodiode with electronic attenuation Fluorescence Detectors: FL1 – FL6 Fluorescent Detectors Flow rates: Continuous pressure is applied to the sample tube based on user selected flow rates: Low, Medium and High Performance: Carryover: < 0.1%, Dead volume as low as 2 µL when using Beckman Coulter 12 x 75 mm polypropylene tube and adjustable probe Acquisition modes: 32 tube Multi Carousel Loader (MCL), Single tube sampling mode, Automated work list acquisition, Manual work list mode Mixing: The MCL vortexes each tube individually before sample acquisition Barcode reading: Carousel number, tube location, and tube barcode verified to worklist Biosafety: Biohazard contained wash station thoroughly rinses sample probe Throughput: 10000 normal leukocytes is 82 tubes/hour Scatter resolution: Resolves 0.4 micron particles from background noise using Forward Scatter, Maximum detection of up to 40 microns Fluorescence sensitivity: FITC < 107 MESF, PE < 64 MESF, PC5 < 13 MESF Acquisition rate: 25000 events per second, 90% yield Cytometer dimensions (WxHxD): 950 x 610 x 730 mm Cytometer weight: 104 kg Supply cart dimensions (WxHxD): 724 x 298 x 495 mm Supply cart weight: 30 kg Software included but requires a new licence purchase.

€4,950.00 ex VAT
Netherlands
particle counters, flow cytometers
Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab-cover
Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab

Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab This system was rem (more)oved from a university where it was surplus to requirement. It is in good cosmetic condition, the working condition of each unit that we were able to test is listed below. Parts of the system:- Optics Table - MoFlo Optical BenchSN - 2086Dimensions - L153 W122 H80.5cmMeasurement - Imperial Parts fitted on table:- Pressure Console UnitSN - 2086 Coherent SapphireModel - Sapphire LP USB CDRH Driver Unit w/displayPN - 1189089SN - LDP.1189089.C02070- Powers on Coherrent Sapphire 488-200 CW CDRHPN - 1137970SN - LDP.1137970.521683Heatsink Sapphire LP RoHS compl- NOT TESTED Coherrent CubePN - 1170509SN - C20010803- NOT TESTED Coherrent CubePN - 1193821/AASN - C14070901- NOT TESTED Hamamatsu Parts:-H957-27 (No.T0050)H957-18 (No.K0149)H957-27 (No.T3721)H957-25 (No.S0319)H957-25 (No.S0360)H957-25 (No.S0359)H957-25 (No.S0322)H957-25 (No.S0324)H957-27 (No.T0051)H957-27 (No.T0054)H957-25 (No.S0358)H957-25 (No.S0321)H957-25 (No.S0323) Smart Sampler 2 x Preamplifier UnitsSN - 2086 DTx Data Display 19" LCD w/TouchscreenBCI PN - B44222DTx PN - 90819SN - BCM0514F37003- Powers on via Miami MoFlo XDP Controller Under table units:- DTx BCI Miami MoFlo XDP ControllerDTx PN - 90692BCI PN - B20566DTx SN - BCM0915F44602- Powers on - When powered up, an error message reads 'OdinInstControl::connectMachine failed: AttachedInstrument::GetInstance:Repository had communication error!' Gast Vacuum PumpDOA-P501-BN- Powers on Intellipower UPSModel - IQ200V-C-DiAC-Isol-PFCSN - 2FKVDIFC5B15110524- Powers on Beckman Coulter Aerosol Evacuation System Buffalo Filter w/ PedalModel - 200-0179SN - 502135Has ViroSafe Filter fitted (PN-200-8166)- Powers on. 3 x 316L UM Alloy Products Corp Pressure Vessels:-SN - S533735-1-005 (2014)SN - S514233-1-011 (2010)SN - S507165-1-008 (2008) Other units:- Thermo Scientific Recirculating Water BathControl - C10 Type - 003-5009/SN - 1 08004133017Bath - K20 Type - 002-4276/SN - 08004052 003- Powers on Testing:-37˚c - Thermometer read 37.6˚c100˚c - Thermometer read 100.0˚c-20˚c - Thermometer didn't read lower than -13.5˚c Jun Air CompressorType - OF302-25MQSN - 0119802962- Powers on with compressor running Hours - 00898.3 Other spare bits:-1 x Black Case of various filters1 x Black Case containing 3 x Merlin Gerin fuses, Methanol &amp; Acetone2 x Sets of Spare Shaped Charged Plates (one pair boxed)1 x Box of Filters1 x Box of mixed size O-ringsRed Ethernet cable5 x IEC Extension cables

£15,000.00 ex VAT
United Kingdom
flow cytometers, laboratory modules
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]