Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Perkin Elmer
Location
Caerphilly - United Kingdom
Price
£905.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Perkin Elmer Fluorescence Spectrometer Model - LS 45 Lab

£905.00 (ex VAT)
item image

Description from the supplier

This Perkin Elmer Fluorescence Spectrometer Model - LS 45 was removed from a university lab where it was surplus to requirements.
The system has been serviced and recertified and is in full working order. We have a full report available on request.
There is no software included
It is in excellent cosmetic condition and is supplied with the following;
1 x LS50B S/W Upgrade to LS 55 Issue B - some items are missing.1 x Box labelled L225-8000

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Bruker LC-NMR-MS Interface-cover
Bruker LC-NMR-MS Interface

The LC-NMR-MS Interface is designed to sit between an HPLC system, an NMR spectroscopy probehead and (more) an MS unit. It would normally be mounted on top of the MS table immediately in front of the MS input connector. The BNMI-HP consists of 3 medium pressure (> 60Bar) syringe pumps, a 1:20 splitter, an 8-Port valve, 3 mixing chambers (T-Pieces) and associated control and interface electronics. The flow of the HPLC separations to the MS unit can be modified by pumping additional solvent from the syringe pumps. This improves the MS peak detection and shortens the time needed for the split separation to reach the MS. Separations can also be stored as a result of an MS peak detection as well as through UV absorption peak detection. The splitter splits the fluid flow from the HPLC in a 1:20 ratio. i.e. ca. 5% of the fluid is directed to the MS and the remainder to either the NMR probehead for immediate analysis or to the BPSU36 storage cassette for storage and later analysis.  The fluid directed to the MS is mixed in the mixing chamber (T-Piece) with the solvent pumped from the syringe pumps. The two left hand syringe pumps pump alternatively to guarantee a constant ’makeup’ flow. The 3rd pump at the right hand side is used to pump a calibration fluid into the flow path to allow the MS to be calibrated (or simply synchronized) at the start and end of each measurement cycle. The 8-Port valve is used to direct the fluid flow. Control of the BNMI Unit is performed using the HyStar program via an ethernet interface. Commands received from HyStar are interpreted in the BNMI Control Board. The control board then sets up the BNMI unit accordingly e.g.: Starts the pumps, changes the flow rate, turns the 8-Port valve. The splitter has a fixed mechanical function and cannot be controlled or adjusted. It simply accepts a fluid flow and splits it into 2 paths in a 1:20 ratio. However, other split ratios are available (for example 1:100 may be preferred if you have very high sample concentrations).

€1,499.00 ex VAT
Netherlands
nmr spectrometers
People are watching right now:
Radwag Stainless Steel Wire, Set (1 mg - 500 mg), Plastic Box-cover
Radwag Stainless Steel Wire, Set (1 mg - 500 mg), Plastic Box

Stainless Steel Wire - set (1 mg - 500 mg) E2-class mass standards represent an exceptional standard (more) of precision in mass measurement. Classed as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class mass standards - key features High precision measurements - Class E2 mass standards must meet stringent measurement precision standards. The permissible deviations from the actual mass are strict, making this class of standards the ideal solution for applications requiring extreme accuracy. Stability over Time - An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control - Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications - E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. The set includes: plastic box 12 mass standards 1 pair of tweezers 1 brush Material: stainless steel Zastosowanie 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€783.00 ex VAT
Poland
mass standards
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]