Edwards E2M1.5 Vacuum Pump

Marshall Scientific$2,417.00 (ex VAT)
item image

Description by the supplier

Edwards E2M1.5 Vacuum Pump



Ultimate Vacuum

3 x 10-3 mbar

Inlet Connection

NW10

Displacement

2.2 m3h-1 / 1.3 ft3min-1



Features

- High ultimate vacuum and rapid pumping speed ensure efficient operation across a wide range of laboratory and industrial applications

- Quiet operation provides a comfortable working environment, reducing noise in sensitive areas

- Features a pressurized oil system that lubricates pump shaft bearings and rotor sealing faces for reliable performance

- Maintenance is simplified with an oil sight-glass for easy monitoring of oil levels and conditions at a glance

- Facilitates easy oil changes with an oil drain plug that allows either gravity or pressure oil drainage for convenience

- Compact, freestanding design allows flexible use without the need for additional support structures

- Ideal for use with analytical instruments, leak detectors, helium research, and for backing turbomolecular pumps, showcasing its versatility






The EM range of oil‑sealed rotary pumps – renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and ability to handle vapour – have become the industry standard for laboratory and light industrial applications. The pump is a freestanding unit with the drive provided through a flexible coupling by either a single‑phase or three‑phase (four pole) motor.

Click Here to View Product Video


INCLUDED:

The Edwards E2M1.5 Vacuum Pump includes:

- Edwards Ultragrade Performance 15 Oil

- Power Cord

- Manufacturer's Documentation

- Operator's Manual

- 1 Year Manufacturer's Warranty

Product details
Displacement (swept volume)
50 Hz1.8 m3h-1 / 1 ft3min-1
60 Hz2.2 m3h-1 / 1.3 ft3min-1
Speed (Pneurop 6602)
50 Hz1.6 m3h-1 / 0.8 ft3min-1
60 Hz2.0 m3h-1 / 1.2 ft3min-1
Ultimate vacuum (total pressure)
without gas ballast3 x 10-3 mbar / 2.3 x 10-3 Torr
with gas ballast2.5 x 10-2 mbar / 1.9 x 10-2 Torr
Inlet connectionNW10 flange
Outlet connectionNozzle 11 mm external diameter removable from 3/8 inch BSP tapped hole
Maximum permitted pressure at outlet0.5 bar gauge / 7 psig
Maximum inlet pressure for water vapour15 mbar / 11 Torr
Maximum water vapour pumping rate16 gh-1
Motor power 50/60 Hz (IP54)0.16 kW
Nominal rotation speed 50/60Hz2800/3400 rpm
Power connectorIEC EN60320 C13
Operating temperature range12 - 40 °C
Weight10 kg / 22 lbs
Noise54 dB (A) @ 50 Hz
Noise with acoustic enclosure47 dB(A) @ 50Hz
Oil capacity - max0.28 litre
min0.2 litre
Recommended oilUltragrade 15
Electrical Requirements100-120V, 50/60Hz (For 230V option please contact)
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Edwards nXR90i NW40 Multi Stage Roots Dry Pump, 115/230V-cover
Edwards nXR90i NW40 Multi Stage Roots Dry Pump, 115/230V

Edwards nXR90i NW40 Multi Stage Roots Dry Pump Ultimate Vacuum 0.03 mbar (0.022 Torr) Inlet Connecti (more)on NW40 Displacement 90 m 3h-1 Features - Achieves an ultimate vacuum of 0.03 mbar (0.022 Torr), ideal for precision tasks - Supports a maximum outlet pressure of 0.2 bar gauge for enhanced application flexibility - Operates at a continuous inlet pressure of 1013 mbar, accommodating various systems - Maintains a leak tightness of < 1x10⁻⁶ mbar l/s for reliable operation - Designed to fit under benchtops, optimizing laboratory space - Ensures a clean, oil-free operation, reducing contamination risks - Keeps the vacuum chamber free from dust, maintaining a clean environment - Seamlessly integrates into existing vacuum systems for OEMs - Provides reliable vacuum performance over long periods, ensuring operational stability - Low maintenance reduces downtime ensuring research continuity Edwards has revolutionised the vacuum pump market with the new nXRi high performance, compact dry pump. It delivers unrivalled pumping speeds in the most compact package, with pumping speeds of 30 to 120 m3h-1. The nXRi's lower input power and zero maintenance create real performance improvements and cost benefits across a range of applications.Analytical Instrument OEMs benefit from the ease of integration into most vacuum systems for a ready to go vacuum solution, perfect for mass spectrometry, electron microscopy and leak detection. R&D and Industrial customers will enjoy the design flexibility, oil-free and low maintenance features.Click Here to View Product Video INCLUDED: The Edwards nXR90i NW40 Multi Stage Roots Dry Pump includes: - Operator's Manual - 1 Year Manufacturer's Warranty

$17,847.00 ex VAT
United States
pumps liquid & other
Edwards RV3 Rotary Vane Vacuum Pump-cover
Edwards RV3 Rotary Vane Vacuum Pump

Edwards RV3 Vacuum PumpFeatures - The RV is a truly versatile pump for operation throughout for your (more) operations, perfect for wet applications, dusty applications and clean dry applications. - The RV series of pumps has the highest vapour handling capacity of any rotary vane pump. This is ideally suited for your wet pumping applications such as freeze drying, extraction, filtration and gel drying. - The best-in-class anti-suck back protection prevents dust or oil mist from entering your system. The fast-acting automatic inlet valve acts within 0.4 seconds. - The universal motor in the pump covers the widest possible voltage and frequency range from a single motor. - You can service and replace parts without dismantling the pump mechanism. All parts self-align, eliminating the need for special assembly. Pump valve has "controlled" opening on power startup so that the system vacuum will never see a pressure surge on startup The RV uses a high-quality "universal" motor to cover the widest possible voltage and frequency range. A one-size Allen key is used to dismantle all parts of the RV pump. All rotor and stator parts are completely interchangeable The RV series of small oil sealed rotary vane pumps deliver excellent ultimate vacuum pressure, high pumping speeds and superior vapour handling capabilities with quiet operation. With over 300,000 units produced, these pumps offer proven performance that sets the industry standard for R&D and scientific pumping applications. All RV pumps are approved to UL and CSA standards by an external test house and feature our unique mode selector switch, meaning one model is suitable for both high vacuum or high throughput applications. Click Here to View Product Video INCLUDED: The Edwards RV3 Rotary Vane Vacuum Pump includes: - 1 Liter of Edwards Ultragrade 19 Oil - Power Cord - Manufacturer's Documentation - Operator's Manual - 1 Year Manufacturer's Warranty

$2,934.00 ex VAT
United States
pumps liquid & other, vacuum pumps
Edwards nXDS20iC Dry Scroll Pump-cover
Edwards nXDS20iC Dry Scroll Pump

Edwards nXDS20iC Dry Scroll PumpFeatures - Bearing shield ensures separation between process gases a (more)nd bearing lubrication to ensure clean vacuum and no possibility of contamination. - Smart motor drive means consistent performance globally, pump overload protection and remote start/stop capability. - High flow gas ballast feature allows pumping of vapours including water vapour at up to 240 gh-1 - Simple single sided scroll design allows maintenance to be done in minutes for low cost of ownership and maximum up-time. - Enhanced versions offer up to 20% lower peak power requirements during initial pump down. The nXDS allows a wide range of control and communication options The nXDS comes as standard with a manual, easy to use, gas ballast port A perfect companion for your turbomolecular pump With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features Edwards nXDS is the best performing pump in its class.nXDS improves on legacy XDS pumps by offering increased pumping speeds, combined with lower ultimate pressures, lower power consumption and lower noise - up to 20 times quieter than other pumps. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. nXDS pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimised pumping performance globally. The Edwards nXDS20iC features Chemraz internal valves and stainlesssteel fittings for extra protection from the pumped media. The ‘C’ series isbetter designed for more aggressive applications as opposed to the standardseries. Click Here to View Product Video INCLUDED: The Edwards nXDS20iC Dry Scroll Pump includes: - 1 Year Full Parts and Labor Warranty - Power Cord - Manufacturer's Documentation - Operator's Manual Edwards nXDS20iC Dry Scroll Pump Technical SpecificationsNominal rotational speed1800 rpmDisplacement28.0 m3h-1 / 16.5 ft3min-1Peak pumping speed22.0 m3h-1 / 13.0 ft3min-1Ultimate vacuum (total pressure)0.030 mbar / 0.022 TorrMinimum standby rotational speed1200 rpmSpeed control resolution (percentage of full rotation speed)1%Pumping speed at minimum rotational speed10Maximum continuous inlet pressure50 mbarMotor power 1-ph260 WPower connector 1-phIEC EN60320 C13Recommended fuse10A, 250Vac rmsWeight25.6 kg / 56 lbInlet flangeNW25Exhaust flangeNW25Noise level52 dB(A)Vibration at inlet flange< 4.5 mms-1 (rms)Leak tightness (static)< 1x10-6 mbar ls-1Operating temperature range10 to 40 °C / 41 to 104 °FElectrical Supply115/230VComparison of ModelsParameterEdwards nXDS6iCEdwards nXDS10iCEdwards nXDS15iCEdwards nXDS20iCNominal rotational speed (rpm)1800180018001800Displacement (m³h⁻¹ / ft³min⁻¹)6.2 / 3.612.7 / 7.517.1 / 10.128.0 / 16.5Peak pumping speed (m³h⁻¹ / ft³min⁻¹)6.2 / 3.611.4 / 6.715.1 / 8.922.0 / 13.0Ultimate vacuum (total pressure) (mbar / Torr)0.020 / 0.0150.007 / 0.0050.007 / 0.0050.030 / 0.022Weight (kg / lb)26.2 / 5825.8 / 5725.2 / 5625.6 / 56Inlet flangeNW25NW25NW25NW25Noise level (dB(A))52525252Operating temperature range (°C / °F)10 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 104Electrical Supply115/230V115/230V115/230V115/230V.comparison-table tr td:nth-child(5) { background-color: #fffacd; }

$9,865.00 ex VAT
United States
pumps liquid & other
Edwards nXDS10i Dry Scroll Pump-cover
Edwards nXDS10i Dry Scroll Pump

Edwards nXDS10i Dry Scroll PumpFeatures - Bearing shield ensures separation between process gases an (more)d bearing lubrication to ensure clean vacuum and no possibility of contamination. - Smart motor drive means consistent performance globally, pump overload protection and remote start/stop capability. - High flow gas ballast feature allows pumping of vapours including water vapour at up to 240 gh-1 - Simple single sided scroll design allows maintenance to be done in minutes for low cost of ownership and maximum up-time. - Enhanced versions offer up to 20% lower peak power requirements during initial pump down. The nXDS allows a wide range of control and communication options The nXDS comes as standard with a manual, easy to use, gas ballast port A perfect companion for your turbomolecular pump With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features Edwards nXDS is the best performing pump in its class.nXDS improves on legacy XDS pumps by offering increased pumping speeds, combined with lower ultimate pressures, lower power consumption and lower noise - up to 20 times quieter than other pumps. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. nXDS pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimised pumping performance globally. Click Here to View Product Video INCLUDED: The Edwards nXDS10i Dry Scroll Pump includes: - Power Cord - Manufacturer's Documentation - Operator's Manual - 1 Year Manufacturer's Warranty

$6,884.00 ex VAT
United States
pumps liquid & other
People are watching right now:
Bio-Rad DCode Universal Mutation Detection System-cover
Bio-Rad DCode Universal Mutation Detection System

The search for unknown mutations in genomic DNA is important for studying the genetic basis of disea (more)ses and disorders, including cancer. Additionally, examining DNA polymorphisms is useful for ecological and evolutionary studies of terrestrial, marine, and microbial organisms, with applications ranging from species identification to delineation of population structure to monitoring genetic diversity. The DCode universal mutation detection system can scan for single-base changes by any of the following electrophoretic techniques: Single-stranded conformation polymorphism (SSCP) Denaturing gradient gel electrophoresis (DGGE) Constant denaturing gel electrophoresis (CDGE) Temporal temperature gradient gel electrophoresis (TTGE) Flexible and powerful, the DCode system is the one electrophoresis system that can perform any combination of these techniques. At the center of the system is the temperature control module (which includes a microprocessor-controlled heater, a buffer-recirculating pump, and a stirrer). For techniques requiring accurate temperature control, such as SSCP and TTGE, the gels are immersed in the buffer, and temperatures are regulated between 5° and 70°C. Any run temperature below ambient can be achieved with the cooling tank used in conjunction with an external laboratory chiller. The DCode system can run 64 samples in as little as 2 hours — a major consideration when you’re screening DNA for sequence variations. You can configure your DCode system to grow as your needs grow. Each system includes a vertical electrophoresis cell and choice of adaptor kits for SSCP, DGGE, and CDGE, as well as for TTGE, a technique codeveloped by Bio-Rad. TTGE has all the benefits of DGGE and CDGE without chemical denaturant gradients. Glass plates: 200 x 200 mm Gel sizes: 160 x 200 mm (maximum two per run) Heater and control: Temperature control (PID type) ±0.5°C variation within gel area, ±0.5°C actual in the range of 45 – 70°C Dimensions (WxDxH): 390 x 200 x 420 mm Weight: 16 kg

€629.00 ex VAT
Netherlands
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]