Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Bruker
Model
Bruker D2 Phaser Benchtop XRD
Location
Caerphilly - United Kingdom
Price
£22,500.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Bruker D2 Phaser Benchtop XRD Diffractometer Lab

£22,500.00 (ex VAT)
item image

Description from the supplier

  • USB stick
  • Key
  • Keyboard
  • Mouse
  • Model: A26-X1-A2B0B2B
  • S/N: 204931

Product details

Electrical Supply1-Phase
PAT Test ResultPass
PAT Test Date12-12-2024
Voltage240V
Plug Included? (1-Phase)Yes - Standard UK 3-Pin Mains Plug (BS 1363)
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Rigaku - XRD Parts MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R  
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Rigaku - XRD Parts MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R NOTE - THIS IS A SPARES/REPAIRS ITEM

Rigaku MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R System Lab This system was removed fro (more)m a university where it was surplus to requirement. All units are in excellent cosmetic condition. This Rigaku X-ray generator is reportedly in working condition according to the previous owner. However, some parts, such as the detector, were removed for spares to keep another system running. No testing was conducted, as the main unit requires a transformed three-phase 400-volt to a 200-volt three-phase supply. Therefore, we cannot confirm its working condition and therefore it is listed as Spares/Repair. This system comprises the following: Rigaku MicroMax-007HFModel RA-MICRO7HFM_RACSerial No. ID211302 The main control system is mounted on a cabinet 100 cm x 60 cm x 90 cm high with a metric 2.5 cm hole spacing isolation tabletop.The operating unit mounted on the table is 40 cm x 30 cm x 55 cm high Rigaku Model AFC-11R detector base and positioning unitSerial No. ID02493 Technifab Products cryogenic sample preparation unit52 cm platform with 9 cm central hole with insulated bung26 cm diameter x 22 cm deep stainless vessel Accessories: 1 x Rigaku Osmic Varimax Optical Fixture Serial No. 25001 x Rigaku Crystallography X-ray XRF Model CU 4364F5012 x Rigaku X-Ray Diffractometer Instruction ManualsSeveral lengths of colour coded 5mm tubing1 x Hampton Research HR4-767 XYZ heated goniometer head1 x Hampton Research HR4-643 XYZ short standard goniometer head1 x PEX4S553B PCB/card to interface with 4 coms sockets

£1,750.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Rigaku Ultima III X-ray Diffractometer (XRD) w/SA-HEM3 6 Station Holder Lab-cover
Rigaku Ultima III X-ray Diffractometer (XRD) w/SA-HEM3 6 Station Holder Lab

Rigaku X-ray Diffractometer (XRD) Ultima III This system was removed from a university lab where it  (more)was surplus to requirements. The system is in reasonable used cosmetic condition. It has not been powered on at our site due to our on-site risk assessments surrounded X-Rays. Various components and parts are included as listed below, along with a PC setup, although no Rigaku software programs appear to be installed on the PC.However, there are the following software disks included: - Rigaku Basic Software (Cat No.: 9240J101) - Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101) - Rigaku Special Order Software (U30megaP) (Cat No.: 9999) System Specifications: - Model: Ultima III - Cat No.: 2035M410 - Serial No.: DD3654N - 6 Station Holder - Model: SA-HEM3 - Cat No.: 4057J101 - Serial No.: 00563702 - Patlite Beacon - Model: LMS-L (SN-06X03M) - Rigaku DC Motor Controller - SN: DD12866 - Rigaku Long Fine Focus - Type: R01-29-0202 - NC: 9430 022 73201 - No. DK 402688 - Rigaku CBO Cross Beam Optics - Cat No.: 2220B101 - SN: DD12793 - Additional Rigaku parts: - Cat No.: 5738E402 (SN-DD061813) - Cat No.: 2155G101 (SN-DD12804) - Cat No.: 4601K831 (SN-DD12154) - Cat No.: 4253A101 (SN-DD11586 - Vexta Stopping Motor - Model: PK543-A - SN: UR70J32307 PC Setup: - Dell Optiplex 9020 with monitor, keyboard, and mouse - The PC is in working order with all passwords cleared. It contains a few Rigaku files, but no software programs appear to be installed. Included Manuals/Software: - 2 x Rigaku D/MAX 2000/PC Series Instruction Manual - X-Ray Diffractometer Instruction Manual - Rigaku Basic Software (Cat No.: 9240J101) - Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101) - Rigaku Special Order Software (U30megaP) (Cat No.: 9999) Loose spare parts included: - Rigaku Cat No.: 2701E201 (SN-AD08851) - Container of round parts: Rigaku 900003 SH, w/Groove - 2 x Small containers with unknown parts - Scintag Generator Key - Key labeled: "Microscope" - Container of small metals, including: - 1 x Bag labeled "Silicon" - 1 x 640d Silicon Powder - 2 x Tubs UCAR Spectroscopic Powder - 1 x Tub labeled "Tung Flake" - Approximately 20 x small containers of Silicon metal

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction X-ray Generator System This system was remo (more)ved from a university lab where it was surplus to requirements. The system is in very good cosmetic condition, but several units encountered issues during testing, and no PC or control software is included. As such, the system is listed for spares/repair. - Further information regarding issues faced are stated below. The lab stated it had been not used for some time but had some issues. The system units include: - Oxford Diffraction Xcalibur PX Ultra - Serial No.: XXH-127/05 - Year: 2005 - Powered on with mains light, Shutter Closed status light, inner display screen, and hand-held remote keypad all functioning - Oxford Diffraction X-ray Protection Cabinet - Serial No.: XPD-127/05 - Year: 2005 - Thermo Scientific Neslab ThermoFlex 10,000 Recirculating Chiller - Serial No.: 1111473501170217 - Powered on but shut off after 1 second with error code "PHEr" (limit fault) - Oxford Diffraction KMW200CCD CCD Detector Chiller Unit - Serial No.: CCA 73/06 - Year: 2006 - Powered on, but no further testing possible - Oxford Diffraction KMC3000C X-ray Tube Chiller - Serial No.: CAC-142/05 - Year: 2005 - Powered on, pump ran, thermostat seemed functional, but not fully tested - Oxford Diffraction Cryodrive 2.0 - Serial No.: R72-0558 - 6944 running hours - Powered on, but no further testing without gas supply - Oxford Cryosystems Cobra Controller 700 Series Cold Head Controller - Serial No.: 741174 - Powered on, displayed ambient temperature, status lights, and responsive buttons - Parker NitroFlowLab Nitrogen Generator - Model No.: 4278 - Serial No.: 4278-13NFLC0008 - Powered on, displayed a message "writing information to an SD card," and did not allow further actions - Oxford Cryosystems Standard Cobra Nitrogen Control Pump - Serial No.: CB171 - Agilent HS 602 Vacuum Pump with NW25 Oil Exhaust Filter - Model: 849-9365R001 - Serial No.: 232830 - Year: 2006 - Produced a vacuum but failed a PAT test on insulation Additional notes: - All units passed a PAT test except for the Agilent vacuum pump, which failed due to insulation issues. - The Xcalibur unit and Neslab chiller were only visually tested due to larger power plugs. Manuals included: - Oxford Instruments Object Bench Software handbook - Xcalibur Series user manual - Thermo Scientific Recirculating Chiller Operation, Installation, and Maintenance manual - Oxford Diffraction KMC3000C user manual - Oxford Cryosystems Cobra operation guide - Safety Matters cryogenic safety manual - 2 x CrysAlis Pro user manuals - Oxford Instruments Cryojet Controller UMC002 manual - Workstation 4 VMware v4.52 Virtual Machine Software and manual Accessories included: - 1 x set of keys for safety cabinet - 1 x Long Fine Focus unit (Type OD2773/00, No. 163054) - 3 x glass vacuum traps (2 litres approx.) - 2 x vacuum pump platforms - 2 x Parker wound filter cartridges (Part No.: M11R10A) - 2 x Agilent KMW3000 filter cartridges (Part No.: IJ-00-01-002) - 1 x carbon filter nitroflow mobile - 6 x data cables - 4 x Cobra stainless steel line drier units - 1 x 4-way valve purge block - 1 x box of stainless armoured hose pipe and 1/4" plastic tubing

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
People are watching right now:
Radwag MA 210.X2.A.WH Moisture Analyzer-cover
Radwag MA 210.X2.A.WH Moisture Analyzer

MA X2.A moisture analyzers are hi-tech measuring instruments intended for quick determination of rel (more)ative moisture content, dry mass content and other parameters in samples of different substances. MA.X2.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X2.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X2 Series moisture analyzers: Automatic opening and closing of the drying chamber 5” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X2.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€1,836.00 ex VAT
Poland
balances, moisture analysers
Pfeiffer HiCube 300 Neo, 100 ISO-K, MVP 030-3 Turbo Pumping Station-cover
Pfeiffer HiCube 300 Neo, 100 ISO-K, MVP 030-3 Turbo Pumping Station

Pfeiffer HiCube 300 Neo, 100 ISO-K, MVP 030-3 Turbo Pumping Station Final Pressure 1 x10-7 hPa / 7. (more)5 x 10-8 Torr / 1 x 10-7 mbar Backing Pump Speed 1.8 m³/h / 1.06 cfm / 30 l/min Pumping Speed for N2 260 l/s Features - Compact series of pumping stations for all high vacuum applications - Simple operation with 7in. touch display - Remote control via web server available - Compatible with a wide variety of applications - Reliable and robust The Pfeiffer HiCube 300 Neo, 100 ISO-K, MVP 030-3 Turbo Pumping Station is a compact, high-performance solution for all high vacuum applications. It offers simple operation through a 7-inch touch display and can be controlled remotely via a web server, making it highly versatile and user-friendly. Designed for reliability, it operates with a final pressure of 1 x 10⁻⁷ mbar and a pumping speed of 260 l/s for nitrogen. The backing pump, the MVP 030-3, delivers a pumping speed of 1.8 m³/h at 50 Hz, ensuring efficient performance. This turbo pumping station uses air-cooled forced convection to maintain optimal conditions and operates quietly with a sound pressure level of ≤50 dB(A). Its HiPace 300 turbopump and DN 100 ISO-K connection flange make it compatible with a variety of applications. Built to work worldwide, it supports input voltages ranging from 100-240 V AC. Weighing 20.5 kg, it is robust and reliable, offering consistent performance in environments with ambient temperatures from 5 to 40°C. INCLUDED: The Pfeiffer HiCube 300 Neo, 100 ISO-K, MVP 030-3 Turbo Pumping Station includes: - Backing Pump - Pfeiffer MVP 030-3 Diaphragm Pump - Protective Cap for High Vacuum Flange - Power Cord - Operator's Manual - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$17,200.00 ex VAT
United States
pumps liquid & other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]