Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Unigreenscheme£4,000.00 (ex VAT)
item image

1 / 117
Description by the supplier

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction X-ray Generator System

This system was removed from a university lab where it was surplus to requirements.

The system is in very good cosmetic condition, but several units encountered issues during testing, and no PC or control software is included. As such, the system is listed for spares/repair. - Further information regarding issues faced are stated below.

The lab stated it had been not used for some time but had some issues.

The system units include:

- Oxford Diffraction Xcalibur PX Ultra

- Serial No.: XXH-127/05

- Year: 2005

- Powered on with mains light, Shutter Closed status light, inner display screen, and hand-held remote keypad all functioning


- Oxford Diffraction X-ray Protection Cabinet

- Serial No.: XPD-127/05

- Year: 2005


- Thermo Scientific Neslab ThermoFlex 10,000 Recirculating Chiller

- Serial No.: 1111473501170217

- Powered on but shut off after 1 second with error code "PHEr" (limit fault)


- Oxford Diffraction KMW200CCD CCD Detector Chiller Unit

- Serial No.: CCA 73/06

- Year: 2006

- Powered on, but no further testing possible


- Oxford Diffraction KMC3000C X-ray Tube Chiller

- Serial No.: CAC-142/05

- Year: 2005

- Powered on, pump ran, thermostat seemed functional, but not fully tested


- Oxford Diffraction Cryodrive 2.0

- Serial No.: R72-0558

- 6944 running hours

- Powered on, but no further testing without gas supply


- Oxford Cryosystems Cobra Controller 700 Series Cold Head Controller

- Serial No.: 741174

- Powered on, displayed ambient temperature, status lights, and responsive buttons


- Parker NitroFlowLab Nitrogen Generator

- Model No.: 4278

- Serial No.: 4278-13NFLC0008

- Powered on, displayed a message "writing information to an SD card," and did not allow further actions


- Oxford Cryosystems Standard Cobra Nitrogen Control Pump

- Serial No.: CB171


- Agilent HS 602 Vacuum Pump with NW25 Oil Exhaust Filter

- Model: 849-9365R001

- Serial No.: 232830

- Year: 2006

- Produced a vacuum but failed a PAT test on insulation


Additional notes:

- All units passed a PAT test except for the Agilent vacuum pump, which failed due to insulation issues.

- The Xcalibur unit and Neslab chiller were only visually tested due to larger power plugs.


Manuals included:

- Oxford Instruments Object Bench Software handbook

- Xcalibur Series user manual

- Thermo Scientific Recirculating Chiller Operation, Installation, and Maintenance manual

- Oxford Diffraction KMC3000C user manual

- Oxford Cryosystems Cobra operation guide

- Safety Matters cryogenic safety manual

- 2 x CrysAlis Pro user manuals

- Oxford Instruments Cryojet Controller UMC002 manual

- Workstation 4 VMware v4.52 Virtual Machine Software and manual


Accessories included:

- 1 x set of keys for safety cabinet

- 1 x Long Fine Focus unit (Type OD2773/00, No. 163054)

- 3 x glass vacuum traps (2 litres approx.)

- 2 x vacuum pump platforms

- 2 x Parker wound filter cartridges (Part No.: M11R10A)

- 2 x Agilent KMW3000 filter cartridges (Part No.: IJ-00-01-002)

- 1 x carbon filter nitroflow mobile

- 6 x data cables

- 4 x Cobra stainless steel line drier units

- 1 x 4-way valve purge block

- 1 x box of stainless armoured hose pipe and 1/4" plastic tubing

Product details
Electrical SupplyN/A
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Rigaku - XRD Parts MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R  
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Rigaku - XRD Parts MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R NOTE - THIS IS A SPARES/REPAIRS ITEM

Rigaku MicroMax-007HF Rotating Anode X-Ray Generator, AFC-11R System Lab This system was removed fro (more)m a university where it was surplus to requirement. All units are in excellent cosmetic condition. This Rigaku X-ray generator is reportedly in working condition according to the previous owner. However, some parts, such as the detector, were removed for spares to keep another system running. No testing was conducted, as the main unit requires a transformed three-phase 400-volt to a 200-volt three-phase supply. Therefore, we cannot confirm its working condition and therefore it is listed as Spares/Repair. This system comprises the following: Rigaku MicroMax-007HFModel RA-MICRO7HFM_RACSerial No. ID211302 The main control system is mounted on a cabinet 100 cm x 60 cm x 90 cm high with a metric 2.5 cm hole spacing isolation tabletop.The operating unit mounted on the table is 40 cm x 30 cm x 55 cm high Rigaku Model AFC-11R detector base and positioning unitSerial No. ID02493 Technifab Products cryogenic sample preparation unit52 cm platform with 9 cm central hole with insulated bung26 cm diameter x 22 cm deep stainless vessel Accessories: 1 x Rigaku Osmic Varimax Optical Fixture Serial No. 25001 x Rigaku Crystallography X-ray XRF Model CU 4364F5012 x Rigaku X-Ray Diffractometer Instruction ManualsSeveral lengths of colour coded 5mm tubing1 x Hampton Research HR4-767 XYZ heated goniometer head1 x Hampton Research HR4-643 XYZ short standard goniometer head1 x PEX4S553B PCB/card to interface with 4 coms sockets

£1,750.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Rigaku Ultima III X-ray Diffractometer (XRD) w/SA-HEM3 6 Station Holder Lab-cover
Rigaku Ultima III X-ray Diffractometer (XRD) w/SA-HEM3 6 Station Holder Lab

Rigaku X-ray Diffractometer (XRD) Ultima III This system was removed from a university lab where it  (more)was surplus to requirements. The system is in reasonable used cosmetic condition. It has not been powered on at our site due to our on-site risk assessments surrounded X-Rays. Various components and parts are included as listed below, along with a PC setup, although no Rigaku software programs appear to be installed on the PC.However, there are the following software disks included: - Rigaku Basic Software (Cat No.: 9240J101) - Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101) - Rigaku Special Order Software (U30megaP) (Cat No.: 9999) System Specifications: - Model: Ultima III - Cat No.: 2035M410 - Serial No.: DD3654N - 6 Station Holder - Model: SA-HEM3 - Cat No.: 4057J101 - Serial No.: 00563702 - Patlite Beacon - Model: LMS-L (SN-06X03M) - Rigaku DC Motor Controller - SN: DD12866 - Rigaku Long Fine Focus - Type: R01-29-0202 - NC: 9430 022 73201 - No. DK 402688 - Rigaku CBO Cross Beam Optics - Cat No.: 2220B101 - SN: DD12793 - Additional Rigaku parts: - Cat No.: 5738E402 (SN-DD061813) - Cat No.: 2155G101 (SN-DD12804) - Cat No.: 4601K831 (SN-DD12154) - Cat No.: 4253A101 (SN-DD11586 - Vexta Stopping Motor - Model: PK543-A - SN: UR70J32307 PC Setup: - Dell Optiplex 9020 with monitor, keyboard, and mouse - The PC is in working order with all passwords cleared. It contains a few Rigaku files, but no software programs appear to be installed. Included Manuals/Software: - 2 x Rigaku D/MAX 2000/PC Series Instruction Manual - X-Ray Diffractometer Instruction Manual - Rigaku Basic Software (Cat No.: 9240J101) - Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101) - Rigaku Special Order Software (U30megaP) (Cat No.: 9999) Loose spare parts included: - Rigaku Cat No.: 2701E201 (SN-AD08851) - Container of round parts: Rigaku 900003 SH, w/Groove - 2 x Small containers with unknown parts - Scintag Generator Key - Key labeled: "Microscope" - Container of small metals, including: - 1 x Bag labeled "Silicon" - 1 x 640d Silicon Powder - 2 x Tubs UCAR Spectroscopic Powder - 1 x Tub labeled "Tung Flake" - Approximately 20 x small containers of Silicon metal

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction X-ray Generator System This system was remo (more)ved from a university lab where it was surplus to requirements. The system is in very good cosmetic condition, but several units encountered issues during testing, and no PC or control software is included. As such, the system is listed for spares/repair. - Further information regarding issues faced are stated below. The lab stated it had been not used for some time but had some issues. The system units include: - Oxford Diffraction Xcalibur PX Ultra - Serial No.: XXH-127/05 - Year: 2005 - Powered on with mains light, Shutter Closed status light, inner display screen, and hand-held remote keypad all functioning - Oxford Diffraction X-ray Protection Cabinet - Serial No.: XPD-127/05 - Year: 2005 - Thermo Scientific Neslab ThermoFlex 10,000 Recirculating Chiller - Serial No.: 1111473501170217 - Powered on but shut off after 1 second with error code "PHEr" (limit fault) - Oxford Diffraction KMW200CCD CCD Detector Chiller Unit - Serial No.: CCA 73/06 - Year: 2006 - Powered on, but no further testing possible - Oxford Diffraction KMC3000C X-ray Tube Chiller - Serial No.: CAC-142/05 - Year: 2005 - Powered on, pump ran, thermostat seemed functional, but not fully tested - Oxford Diffraction Cryodrive 2.0 - Serial No.: R72-0558 - 6944 running hours - Powered on, but no further testing without gas supply - Oxford Cryosystems Cobra Controller 700 Series Cold Head Controller - Serial No.: 741174 - Powered on, displayed ambient temperature, status lights, and responsive buttons - Parker NitroFlowLab Nitrogen Generator - Model No.: 4278 - Serial No.: 4278-13NFLC0008 - Powered on, displayed a message "writing information to an SD card," and did not allow further actions - Oxford Cryosystems Standard Cobra Nitrogen Control Pump - Serial No.: CB171 - Agilent HS 602 Vacuum Pump with NW25 Oil Exhaust Filter - Model: 849-9365R001 - Serial No.: 232830 - Year: 2006 - Produced a vacuum but failed a PAT test on insulation Additional notes: - All units passed a PAT test except for the Agilent vacuum pump, which failed due to insulation issues. - The Xcalibur unit and Neslab chiller were only visually tested due to larger power plugs. Manuals included: - Oxford Instruments Object Bench Software handbook - Xcalibur Series user manual - Thermo Scientific Recirculating Chiller Operation, Installation, and Maintenance manual - Oxford Diffraction KMC3000C user manual - Oxford Cryosystems Cobra operation guide - Safety Matters cryogenic safety manual - 2 x CrysAlis Pro user manuals - Oxford Instruments Cryojet Controller UMC002 manual - Workstation 4 VMware v4.52 Virtual Machine Software and manual Accessories included: - 1 x set of keys for safety cabinet - 1 x Long Fine Focus unit (Type OD2773/00, No. 163054) - 3 x glass vacuum traps (2 litres approx.) - 2 x vacuum pump platforms - 2 x Parker wound filter cartridges (Part No.: M11R10A) - 2 x Agilent KMW3000 filter cartridges (Part No.: IJ-00-01-002) - 1 x carbon filter nitroflow mobile - 6 x data cables - 4 x Cobra stainless steel line drier units - 1 x 4-way valve purge block - 1 x box of stainless armoured hose pipe and 1/4" plastic tubing

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
People are watching right now:
LAUDA ECO ET 15 S heating thermostat-cover
LAUDA ECO ET 15 S heating thermostat

Heating thermostat from 20 to 100°C, with LCD display and simple programming functions LAUDA ECO sta (more)nds out for its range of features and ease of use. ECO thermostats are available in Silver (LCD display; simple programming) and Gold (TFT color display; complex programming) models, equipped with a mini USB interface as standard. A LAUDA innovation is the pressure flow controller located on the front of the head. This means that flow regulation between inside and outside is possible even during operation. - Monochrome LCD graphic display for simultaneous indication of actual and set values - Transparent polycarbonate bath up to 100°C - The circulation pump can be adjusted to six levels - Integrated programmer: 1 program with max. 20 segments - Fully electronic continuous regulator with PID action - Additional key Tmax for overtemperature protection - The most powerful units are equipped with the energy-saving LAUDA SmartCool system - Variants in 230V; the 50 Hz are also available with natural refrigerants - Convenient operation with softkey cursor - Safety class III for operation with flammable and non-flammable liquids. - mini-USB interface - Pump connections with 13mm plastic nipples as standard LAUDA tank thermostats are equipped as standard with a cooling coil. The E 4 model is also equipped with a lid for the bowl and connections for external applications. A drain cock on the rear side makes changing the heat transfer liquid easy and safe. Graph of heating performance of ECO Silver immersion thermostats with polycarbonate bath. Performance graph of the pump pressing on the six levels.

€2,439.00 ex VAT
€2,902.41 incl. VAT if applicable
Italy
thermostats
MARSHALL Select MS-OT20LE Overhead Stirrer, 20L-cover
MARSHALL Select MS-OT20LE Overhead Stirrer, 20L

MARSHALL Select MS-OT20LE Overhead Stirrer, 20L Maximum Stirring Quantity 20L Speed Range 50 to 2,2 (more)00 RPM Maximum Viscosity 100,000 mPas Features - High torque of 40 Ncm suitable for viscous medium stirring - Brushless DC motor ensures long life, maintenance-free operation, and safety in explosive environments - LED display for precise monitoring of actual speed - Over torque protection and safety circuits provide safe stop functions in anti-stall or overload conditions - Large chuck diameter supports many shaft types, increasing versatility - Through-shaft design allows for easy adjustment of the impeller position - Automatic resumption of stirring at preset speed after power loss - IP21 protection class offers basic protection against solid objects and dripping water - Analog speed controls displayed on the LED for easy adjustments and monitoring - Designed to accept pass-through stirrer rods for flexible setup options - Visual alarm alerts for immediate notification of system issues or malfunctions - Explosion-proof motor enhances safety in volatile environments The MARSHALL Select MS-OT20LE Overhead Stirrer stands out for its high reliability and superior performance, engineered to manage stirring tasks up to 20L. It features a versatile speed range from 50 to 2,200 RPM, suited for a wide variety of laboratory needs. This stirrer is equipped with a brushless DC motor, renowned for its long life, maintenance-free operation, and explosion-proof qualities. The MS-OT20LE includes an LED screen that displays the actual speed, ensuring precise control over your mixing processes. It's capable of handling high viscosities up to 100,000 mPas with a maximum torque of 40 Ncm, making it ideal for stirring viscous mediums. The large chuck diameter supports many shaft types, enhancing its adaptability. Safety is a paramount feature of this device, with integrated circuits that provide a safe stop function in conditions of anti-stall or overload, where over torque protection automatically stops the motor. Additionally, the through-shaft design allows for easy adjustment of the impeller position to suit varying laboratory needs. In the event of a power outage, the stirrer automatically resumes operation at the preset speed once power is restored, ensuring continuity and efficiency. The IP21 protection class provides basic protection against solid objects and dripping water, further securing the unit in active laboratory environments. INCLUDED: The MARSHALL Select MS-OT20LE Overhead Stirrer, 20L includes: - Key of Drill Chuck - Power Cord - Operator's Manual - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$609.00 ex VAT
United States
stirrers, overhead stirrers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]