Brand
Perkin Elmer
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€3,500.00 
(€4,165.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 55,00 kg

Categories

Perkin Elmer Polarimeter 341 L300-0011 Glan/Taylor Polarizer Hg + Na Spectral

PROFCONTROL GmbH€3,500.00 
(€4,165.00 incl. VAT* )* - if applicable
item image

Description by the supplier

Manufacturer: Perkin Elmer

Model: Polarimeter 341

P/N: L300-0011

S/N: 9837

YoM: 2008

Description:

Polarimetry is an important technique for the investigation and analysis of optically active substances. Model 341 is a universal and general-purpose precision Polarimeter with Na and Hg source lamps and Glan-Taylor polarizer. Model 341 is a highly versatile instrument for research applications as well as for quality control work. The instrument can be extended into the UV range and is ready for polarimetric HPLC detection. The proven optical null principle, with automatic rotation of the analyzer, is the basis of PerkinElmer’s reputation for excellence in polarimetry. This principle, combined with state-of-the-art microprocessor electronics, results in an instrument which combines the highest possible accuracy and precision with simple operation. For routine measurements simply select the wavelength, insert the sample and read the result. 

Common applications include:

- Characterization of newly synthesized compounds- Quality control of pharmaceutical drugs- Precise quantitative analysis of sugars- Selective detection of optically active components by HPLC- Monitoring and control of enzymatic reactions

Features:

- UV-transmitting Glan/Taylor polarizer- Pure light from Hg and Na spectral lamps- Several interface ports- Simple user interaction- Enhanced sensitivity at low wavelengths- Highly accurate readings- Flexible use as a standalone system with printer, PC system or HPLC detector- Easy operation, quick to learn- Simple operation, database results and method management and customized reporting- Fully meets FDA requirements for regulated industries

Specifications:

- Model 341: Na 589 nm, Hg 578 nm, Hg 546 nm, Hg 436 nm and Hg 365 nm; four spare positions for additional optional filters.- Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control.- Radiation: Hg high-pressure lamp and Na spectral lamp. - Spectral lines: Selectable from instrument keypad.- Apertures: Selectable apertures for standard cells and microcells.- Detector: Photomultiplier 1P28A.- Polarizer and analyzer: UV/Vis-transmitting calcite Glan-Taylor prisms. - Rotatory range: ± 85°.- Balancing speed: 1.3°/s at 50 Hz.- Accuracy: ± 0.002° for rotations =1º; ± 0.2% for rotations >1°.- Reproducibility: Better than 0.002° (for zero and rotational reading).- Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s.- Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range.- User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software.- Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. PC-operation.- Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset.- Printer output: Standard parallel printer port (Centronics port) supporting HP-PCL, Epson esc-p and generic ASCII format.- Communications: RS-232C serial interface, selectable communication parameters.- Data input: Input port for lntermec 9720 barcode reader and/or standard PC/AT keyboard.- Analogue output: Digital-to-analogue conversion of angular rotation for connecting integrators or chart recorders; recording ranges ± 50°, ± 5°, ± 0.5°, ± 0.05°; resolution 0.1% of range width; cyclic repeatability in all ranges; output voltage 0 to 10 mV, 100 mV, and 1 V. External “Ready”: Relay contact closure (normally open), signal floating; maximum load 110 V, 0.3 A AC or 30 V, 1A DC; activated by print signal, selectable delay and duration.- External autozero: External activation of autozero function; TTL signal, low active; or contact closure; duration 100 ms minimum.- Temperature sensor: PT-100 temperature sensor for sample cells (optional accessory); temperature range -23° C to +198° C.- Power requirements: 220-240V, 50Hz- Dimensions (WxHxD): 825 x 310 x 390 mm

Items delivered:

- Perkin Elmer Polarimeter 341

Condition:

The Polarimeter is in excellent cosmetic as well as technical and operating condition. It is 100% functional tested, functions as intended and ready to be operated.

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Perkin Elmer Polarimeter 341 L300-0011 Glan/Taylor Polarizer Hg + Na Spectral-cover
Perkin Elmer Polarimeter 341 L300-0011 Glan/Taylor Polarizer Hg + Na Spectral

Manufacturer: Perkin Elmer Model: Polarimeter 341 P/N: L300-0011 S/N: 9837 YoM: 2008 Description: Po (more)larimetry is an important technique for the investigation and analysis of optically active substances. Model 341 is a universal and general-purpose precision Polarimeter with Na and Hg source lamps and Glan-Taylor polarizer. Model 341 is a highly versatile instrument for research applications as well as for quality control work. The instrument can be extended into the UV range and is ready for polarimetric HPLC detection. The proven optical null principle, with automatic rotation of the analyzer, is the basis of PerkinElmer’s reputation for excellence in polarimetry. This principle, combined with state-of-the-art microprocessor electronics, results in an instrument which combines the highest possible accuracy and precision with simple operation. For routine measurements simply select the wavelength, insert the sample and read the result.  Common applications include: - Characterization of newly synthesized compounds- Quality control of pharmaceutical drugs- Precise quantitative analysis of sugars- Selective detection of optically active components by HPLC- Monitoring and control of enzymatic reactions Features: - UV-transmitting Glan/Taylor polarizer- Pure light from Hg and Na spectral lamps- Several interface ports- Simple user interaction- Enhanced sensitivity at low wavelengths- Highly accurate readings- Flexible use as a standalone system with printer, PC system or HPLC detector- Easy operation, quick to learn- Simple operation, database results and method management and customized reporting- Fully meets FDA requirements for regulated industries Specifications: - Model 341: Na 589 nm, Hg 578 nm, Hg 546 nm, Hg 436 nm and Hg 365 nm; four spare positions for additional optional filters.- Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control.- Radiation: Hg high-pressure lamp and Na spectral lamp. - Spectral lines: Selectable from instrument keypad.- Apertures: Selectable apertures for standard cells and microcells.- Detector: Photomultiplier 1P28A.- Polarizer and analyzer: UV/Vis-transmitting calcite Glan-Taylor prisms. - Rotatory range: ± 85°.- Balancing speed: 1.3°/s at 50 Hz.- Accuracy: ± 0.002° for rotations =1º; ± 0.2% for rotations >1°.- Reproducibility: Better than 0.002° (for zero and rotational reading).- Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s.- Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range.- User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software.- Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. PC-operation.- Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset.- Printer output: Standard parallel printer port (Centronics port) supporting HP-PCL, Epson esc-p and generic ASCII format.- Communications: RS-232C serial interface, selectable communication parameters.- Data input: Input port for lntermec 9720 barcode reader and/or standard PC/AT keyboard.- Analogue output: Digital-to-analogue conversion of angular rotation for connecting integrators or chart recorders; recording ranges ± 50°, ± 5°, ± 0.5°, ± 0.05°; resolution 0.1% of range width; cyclic repeatability in all ranges; output voltage 0 to 10 mV, 100 mV, and 1 V. External “Ready”: Relay contact closure (normally open), signal floating; maximum load 110 V, 0.3 A AC or 30 V, 1A DC; activated by print signal, selectable delay and duration.- External autozero: External activation of autozero function; TTL signal, low active; or contact closure; duration 100 ms minimum.- Temperature sensor: PT-100 temperature sensor for sample cells (optional accessory); temperature range -23° C to +198° C.- Power requirements: 220-240V, 50Hz- Dimensions (WxHxD): 825 x 310 x 390 mm Items delivered: - Perkin Elmer Polarimeter 341 Condition: The Polarimeter is in excellent cosmetic as well as technical and operating condition. It is 100% functional tested, functions as intended and ready to be operated.

€3,500.00 ex VAT
€4,165.00 incl. VAT if applicable
Germany
polarimeters
Perkin Elmer 343 Polarimeter-cover
Perkin Elmer 343 Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
Perkin Elmer Model 343 S Polarimeter-cover
Perkin Elmer Model 343 S Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
People are watching right now:
Scout SKX123 Ohaus-cover
Scout SKX123 Ohaus

Ohaus Scout SKX123 portable scale, with plate Ø 93 mm The OHAUS Scout scale, with its large backlit  (more)LCD display and integrated educational software, is the ideal tool for use in the classroom. It offers premium quality overload protection, fast stabilization times, increased range, more connection options and stackable design - the most advanced learning weighing experience. Applications Weighing, density determination, weighing of moles Screen Liquid crystal display (LCD) with backlight Operation AC adapter (included) or 4 AA batteries (not included) Communication RS232, USB host, USB device, Ethernet or Bluetooth ™ (available as an accessory) Construction ABS housing, stainless steel pan, ABS draft shield (1mg model only), bottom weigh hook, transport lock, manual calibration lock switch, security slot Characteristics of the project Stability indicator, stackable design with storage lid included (excluding 1 mg model), mechanical and software overload / underload protection, low battery indicator, automatic shutdown, automatic tare, span calibration mass included on models with capacity up to 620 g Applications integrated in the scale: - Weighing: allows you to calculate the weight of the samples in the selected unit of measurement. - Density determination: calculation of the density of solids or liquids. Thanks to the integrated weigh below hook, it is possible to carry out tests for the specific gravity of objects that cannot be placed on the weighing pan. - Molar concentration: calculation of the mass of a sample and automatic conversion into the molar concentration.

€458.00 ex VAT
€545.02 incl. VAT if applicable
Italy
weighing terminals, balances accessories
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]