IKA C 200 h Semi-Automated Halogen Resistant Calorimeter


Measuring range max.
40000 J
Measuring time dynamic approx.
8 min
Measuring time isoperibol approx.
17 min

  • Designed for educational institutions and low-volume industrial laboratories
  • Space-saving, standard-conforming combustion calorimeter for liquid and solid samples
  • Manual handling for water and oxygen filling, with optional automation available
  • Offers four working methods: isoperibolic, dynamic, manual, and time-controlled
  • Includes C 5012 halogen-resistant, catalytic activated decomposition vessel
  • Decomposition vessel suitable for high-halogen and sulfur samples (3%)
  • Conforms to standards: DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
  • Hastelloy construction ensures corrosion resistance and high recovery rates for halogen and sulfur analysis
  • Operated via C 6040 CalWin software for monitoring and exporting data to Excel, Word, SQL, or LIMS


The IKA C 200 h Semi-Automated Halogen Resistant Calorimeter is an ideal solution for educational institutions and industrial laboratories requiring precise gross calorific value measurements of liquid and solid samples. Designed for teaching and training purposes, this compact, space-saving device features a semi-automated isoperibol mode, making it perfect for labs with lower analysis volumes. Its robust design ensures compliance with industry standards such as DIN 51900, ISO 1928, and multiple ASTM methods. The package includes essential components like the C 200 calorimeter measuring cell, the halogen-resistant C 5012 decomposition vessel, and an oxygen filling station, providing a comprehensive setup for immediate operation.

  • C 5012 Decomposition vessel, halogen resistant
  • C 200.2 Conversion kit for C 5012
  • C 248 Oxygen filling station
  • Ignation adapter
  • C 200.1 Measuring cup 2000 ml
  • Water emptying hose
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Product details

Measuring Range Max.40000 J
Measuring Mode Dynamic 25°CYes
Measuring Mode Isoperibol 25°CYes
Measuring Time Dynamic Approx.8 Min
Measuring Time Isoperibol Approx.17 Min
Reproducibility Dynamic (1g Benzoic Acid NBS39i)0.1 %RSD
Reproducibility Isoperibol (1g Benzoic Acid NBS39i)0.1 %RSD
Working Temperature Max.25 °C
Temperature Measurement Resolution0.0001 K
Interface PrinterCentronix
Interface PCRS232
Decomposition Vessel C 5012Yes
Decomposition Vessel, Halogen ResistantYes
Works According to DIN 51900Yes
Works According to DIN EN ISO 1716Yes
Works According to DIN EN ISO 18125Yes
Works According to DIN EN 15400Yes
Works According to DIN CEN TS 14918Yes
Works According to DIN CEN/TS 16023Yes
Works According to DIN SPEC 19524Yes
Works According to ASTM D240Yes
Works According to ASTM D4809Yes
Works According to ASTM D5468Yes
Works According to ASTM D5865Yes
Works According to ISO 1928Yes
Works According to GOST CertifiedYes
Dimensions (W x H x D)400 x 400 x 400 mm
Weight29.785 kg
Permissible Ambient Temperature20 - 25 °C
Permissible Relative Humidity80 %
Protection Class According to DIN EN 60529IP 20
RS 232 InterfaceYes
Voltage100 - 240 V
Frequency50/60 Hz
Power Input120 W
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
IKA C 200 h Semi-Automated Halogen Resistant Calorimeter-cover
IKA C 200 h Semi-Automated Halogen Resistant Calorimeter

IKA C 200 h Semi-Automated Halogen Resistant Calorimeter Measuring range max. 40000 J Measuring time (more) dynamic approx. 8 min Measuring time isoperibol approx. 17 min Features - Designed for educational institutions and low-volume industrial laboratories - Space-saving, standard-conforming combustion calorimeter for liquid and solid samples - Manual handling for water and oxygen filling, with optional automation available - Offers four working methods: isoperibolic, dynamic, manual, and time-controlled - Includes C 5012 halogen-resistant, catalytic activated decomposition vessel - Decomposition vessel suitable for high-halogen and sulfur samples (3%) - Conforms to standards: DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711 - Hastelloy construction ensures corrosion resistance and high recovery rates for halogen and sulfur analysis - Operated via C 6040 CalWin software for monitoring and exporting data to Excel, Word, SQL, or LIMS The IKA C 200 h Semi-Automated Halogen Resistant Calorimeter is an ideal solution for educational institutions and industrial laboratories requiring precise gross calorific value measurements of liquid and solid samples. Designed for teaching and training purposes, this compact, space-saving device features a semi-automated isoperibol mode, making it perfect for labs with lower analysis volumes. Its robust design ensures compliance with industry standards such as DIN 51900, ISO 1928, and multiple ASTM methods. The package includes essential components like the C 200 calorimeter measuring cell, the halogen-resistant C 5012 decomposition vessel, and an oxygen filling station, providing a comprehensive setup for immediate operation. Equipped with four operational modes—dynamic, isoperibol, manual, and time-controlled—the C 200 h offers versatile measurement options tailored to user requirements. The halogen-resistant C 5012 decomposition vessel, constructed from corrosion-resistant Hastelloy, ensures superior performance for samples containing halogens or sulfur. Water and oxygen handling is manual but can be upgraded for higher throughput with the optional C 200.RC hose set and RC 2 recirculating chiller. Controlled via C 6040 CalWin software (sold separately), the unit allows seamless monitoring and export of data to Excel, Word, SQL, or LIMS. This versatile calorimeter combines precision, durability, and ease of use, making it a valuable asset for teaching and industrial applications alike.INCLUDED: The IKA C 200 h Semi-Automated Halogen Resistant Calorimeter includes: - C 5012 Decomposition vessel, halogen resistant - C 200.2 Conversion kit for C 5012 - C 248 Oxygen filling station - Ignation adapter - C 200.1 Measuring cup 2000 ml - Water emptying hose - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$22,985.00 ex VAT
United States
laboratory supplies other, calorimeters
IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling-cover
IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling

IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling Measuring Range Max. 40000 J M (more)easuring Time Dynamic Approx. 8 min Cooling Medium Permissable Operating Pressure 2 bar Features - Compact, space-saving, and cost-effective design for educational and low-volume industrial laboratories - Capable of measuring calorific values for liquid and solid samples - Four operation modes: isoperibol, dynamic, manual, and time-controlled (14 min). - Semi-automated system with manual water and oxygen handling, and optional automation available - Closed-loop water circulation with optional RC 2 basic chiller for improved reproducibility and efficiency - Operated via C 6040 CalWin software for monitoring, multi-calorimeter management, and data export - Compatible with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711, GOST 147, GOST 21261 - Compact dimensions (15.7 x 15.7 x 15.7 in.) and lightweight (46.3 lb.) for ease of installation - Installation and calibration consumables included for seamless setup The C 200 auto package allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results. The semi-automated and conforming to standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses. Four different operation modes enable the user to control the measuring times according to individual requirements: Isoperibol: approx: 17 min. Dynamic : approx. 8 min Manual : approx. 17 min (depends on the operator) Time controlled : 14 min Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. The software C 6040 Calwin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. Calwin is sold separately. INCLUDED: The IKA C 200 auto Semi-Automated Calorimeter w/ Automated Water Handling includes: - C 200 Measuring Cell - C 5010 Decomposition Vessel - C 248 Oxygen Filling Station - RC 2 Basic Recirculating Chiller - Ignation Adapter - Water Emptying Hose - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$27,650.00 ex VAT
United States
calorimeters, climate controlled cabinets & enclosures
IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling-cover
IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling

IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling Measuring  (more)Range Max. 40000 J Measuring Time Dynamic Approx. 8 min Cooling Medium Permissable Operating Pressure 2 bar Features - Compact, space-saving, and cost-effective design for educational and low-volume industrial laboratories - Capable of measuring calorific values for liquid and solid samples - Four operation modes: isoperibol, dynamic, manual, and time-controlled (14 min). - Semi-automated system with manual water and oxygen handling, and optional automation available - Closed-loop water circulation with optional RC 2 basic chiller for improved reproducibility and efficiency - Includes C 5012 decomposition vessel, suitable for high-halogen and sulfur samples (3%) - Operated via C 6040 CalWin software for monitoring, multi-calorimeter management, and data export - Compatible with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711, GOST 147, GOST 21261 - Compact dimensions (15.7 x 15.7 x 15.7 in.) and lightweight (46.3 lb.) for ease of installation - Installation and calibration consumables included for seamless setup The IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results. The semi-automated and conforming-to-standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses. The catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and/or sulfur is required after the combustion. Four different operation modes enable the user to control the measuring times according to individual requirements: Isoperibol: approx: 17 min. Dynamic : approx. 8 min Manual : approx. 17 min (depends on the operator) Time controlled : 14 min Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. The software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately. INCLUDED: The IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling includes: - C 5012 Decomposition Vessel, Halogen Resistant - C 200.2 Conversion Kit for C 5012 - C 200.RC Set of Hoses - RC 2 Basic Recirculating Chiller - C 248 Oxygen Filling Station - Ignation Adapter - Water Emptying Hose - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$33,736.00 ex VAT
United States
calorimeters, thermal analysis
IKA C 3000 Automated Calorimeter Package 1/10-cover
IKA C 3000 Automated Calorimeter Package 1/10

IKA C 3000 Automated Calorimeter Package 1/10 Measuring Range Max. 40000 J Reproducibility Dynamic ( (more)1g Benzoic Acid NBS39i) 0.15% Reproducibility Isoperibol (1g Benzoic Acid NBS39i) 0.05% Features - Easy handling via touch screen operation or standard USB mouse - Two choices of starting temperatures (22°C, 30°C) - Automated ignition, water filling and draining and oxygen filling - Several interfaces: Ethernet, RS 232, USB, SD card slot - Six temperature sensors to monitor all temperatures allowing best analysis - Spherically shaped decomposition vessel for better pressure stability and faster heat transfer - Easy sample preparation due to new crucible holder technology - Can be operated with a chiller (e.g. RC 2 basic) The IKA C 3000 Automated Calorimeter Package 1/10 is a state-of-the-art isoperibol calorimeter designed to streamline calorific value measurements with exceptional precision and ease of use. As the advanced successor to the C 2000 model, it introduces cutting-edge features such as fully automated ignition, water handling, and oxygen filling, significantly reducing manual intervention. The intuitive touch screen interface, along with optional USB mouse operation, ensures seamless user interaction, making it an excellent choice for both experienced professionals and newcomers in industrial laboratories. This calorimeter offers unmatched performance with dual starting temperatures (22°C and 30°C), six integrated temperature sensors for precise monitoring, and a spherically shaped decomposition vessel that enhances pressure stability and heat transfer. Capable of achieving up to six dynamic measurements per hour with 0.15% RSD and four isoperibol measurements per hour with 0.05% RSD, the C 3000 excels in efficiency and accuracy. Its robust construction and compliance with globally recognized standards like ISO 1928, ASTM D240, D4809, D5865, and GB T213 make it a reliable solution for critical applications in the power and cement industries. Equipped with advanced data management capabilities, the C 3000 includes Ethernet, RS232, USB, and an SD card slot for flexible connectivity and export options. Additional features such as compatibility with the RC 2 Basic chiller, an upside-down crucible holder for easy sample preparation, and a high-temperature resolution of 0.0001 K further enhance its usability and versatility. Designed to meet the demanding needs of industrial laboratories, the IKA C 3000 Automated Calorimeter Package 1/10 delivers consistent, accurate results, making it an indispensable tool for energy analysis and quality control. INCLUDED: The IKA C 3000 Automated Calorimeter Package 1/10 Handling includes: - C 3000 Measuring Cell - C 6010 decomposition Vessel, Standard - RC 2 Basic Recirculation Chiller - Wear Parts and Consumables for Up to 500 Tests - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$30,530.00 ex VAT
United States
calorimeters
IKA C 6000 Package 1/10 Calorimeter global standards-cover
IKA C 6000 Package 1/10 Calorimeter global standards

IKA C 6000 Package 1/10 Calorimeter global standards Measuring Range Max. 40000 J Reproducibility Dy (more)namic (1g Benzoic Acid NBS39i) 0.15% Reproducibility Isoperibol (1g Benzoic Acid NBS39i) 0.05% Features - Automatic ignition and ignition energy determination - Automatic water filling and draining - Automatic oxygen filling, venting and flushing - RFID technology for automatic decomposition vessel identification - New design of the decomposition vessel allowing easier and faster sample preparation - Easy and convenient capacitive touch screen operation - Control chart view and correction calculation of globally used standards - Ethernet interface to connect a network printer - USB interface allowing easy data management and software updates The IKA C 6000 Package 1/10 Calorimeter redefines modern calorimetry with advanced automation, cutting-edge design, and precision engineering. Operating across adiabatic, isoperibolic, and dynamic modes, it ensures unparalleled flexibility for diverse laboratory needs. With the ability to select three starting temperatures (22°C, 25°C, 30°C), this instrument complies with global standards, including DIN, ISO, ASTM, GOST, and GB. The redesigned decomposition vessel streamlines sample preparation and reduces measurement times, while the capacitive touchscreen interface enhances usability, allowing intuitive operation and fast navigation. This state-of-the-art calorimeter integrates seamlessly into any laboratory workflow with multiple interfaces, including Ethernet, USB, RS232, and RFID technology for automatic vessel identification. The control chart feature and calorific value correction calculations ensure compliance with globally applicable standards, providing reliable, repeatable results. Features like automatic ignition, water filling, oxygen filling, and degasification, coupled with the innovative inverted crucible holder, simplify the most complex processes. Enhanced data management is made possible through USB connectivity and Ethernet interface for network printer integration. Designed for high sample throughput and strict adherence to standards, the C 6000 Package 1/10 includes the RC 2 Basic Circulating Chiller, further optimizing performance and ensuring precise temperature control. Its robust design, featuring a spherically shaped decomposition vessel, improves heat transfer and measurement efficiency. Whether for research, industrial, or educational purposes, the IKA C 6000 Package 1/10 delivers unmatched accuracy, adaptability, and automation, making it an essential tool for modern calorimetry. INCLUDED: The IKA C 6000 Package 1/10 Calorimeter global standards includes: - C 6010 Decomposition Vessel, Standard - RC 2 Basic Recirculation Chiller - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$46,576.00 ex VAT
United States
calorimeters
People are watching right now:
Motic Panthera TEC POL (Trinocular)-cover
Motic Panthera TEC POL (Trinocular)

Motic Panthera TEC POL (Trinocular) Features - UC Plan Achromat objectives (strain-free) for FOV 22m (more)m - Transmitted and transmitted/ incident stand options - Transmitted light: LED/HAL light source interchangeable - Integrated focusable/ centerable Bertrand lens - Motic LightTracer: Coded nosepiece & Digital light intensity knob The Panthera TEC POL series fills a last gap in the Panthera family: Polarization microscopes for all material sciences, ready to handle transparent samples like fibers and foils with their inherent birefringence. The Incident light models for opaque materials work out the specific reflectivity (bireflection) of flat surfaces. To extend the application fields, all microscopes carry an intermediate tube with Bertrand lens to analyze the crystal structure and interference figures of gems, precious stones and minerals.INCLUDED: The Motic Panthera TEC POL (Trinocular) includes: - 4X/0.1 (WD 30.5mm) Objective - 10X/0.25 (WD 17.4mm) Objective - 40X/0.65/S (WD 0.6mm) Objective - 60X/0.8/S (WD 0.35mm) Objective - Widefield UC-WF10X/22mm with Diopter Adjustment - Dust Cover - Power Cord - Allen Key - Blue Filter - Halogen Bulb - Adjustable Key for Nosepiece - Interference Color Chart - Screws for Metal Extension Support - Operator's Guide Motic Panthera TEC POL (Trinocular) SpecificationsOptical systemColour Corrected Infinity Optical System (CCIS®)Observation tubeTrinocular head, Siedentopf typeSensor type-Sensor size-Capture resolution-Live display mode (through Wi-Fi)-Live display mode (through ethernet)-Live display mode (through HDMI)-Inclination25º inclinedTrinocular light splitFixed 50:50Interpupillary distance48-75mmDiopter adjustmentOn both eyepieces, +/- 4 diopterEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentNosepieceReversed quintuple, coded with single centering holesIntermediate BodyRotatable analyzer 360º, Bertrand lens and slot for compensatorsObjective classificationCCIS® UC Plan Achromatic (strain-free), DINObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)Objective mounting threadW 4/5"x1/36" (RMS standard)StageCircular rotating 360º, lockableStage sizeØ160mmTravel range X&Y1º increments, 0.1º vernier scaleCondenserFocusable and centerable Achromat Swing-out Abbe condenser N.A. 0.90/0.13 (strain-free) and rotatable polarizerDiaphragmIris diaphragmFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentFine focus precision2µmFocusing stroke25mmUpper limit stopUpper limit stop preset but adjustableFilter holderOn top of the illuminator with fixing capTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlIllumination interchangeabilityHalogen/LED and LED color temperature interchangeabilityIllumination featuresMotic LightTracer: Light memory, sleep mode (auto on-off), nosepiece LED light intensity and mode indicatorTransformerInternalPower supply110-240V (CE)Other featuresUSB 2.0 for external camera powerDimensions LxWxH410x300x395mmNet weight9.8kgComparison of ModelsSpecificationPanthera TEC POL (Binocular)Panthera TEC POL (Digital)Panthera TEC POL (Trinocular)Optical systemCCISCCISCCISObservation tubeBinocular head, Siedentopf typeBinocular head, Siedentopf type with built-in digital cameraTrinocular head, Siedentopf typeEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)StageCircular rotating 360º, lockableCircular rotating 360º, lockableCircular rotating 360º, lockableStage sizeØ160mmØ160mmØ160mmTravel range X&Y1º increments, 0.1º vernier scale1º increments, 0.1º vernier scale1º increments, 0.1º vernier scaleFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity control.comparison-table tr td:nth-child(4) { background-color: #fffacd; }DownloadsTechnical Specification Download

$3,996.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717