DiaSorin ETI-Max 3000 Fully Automated Microplate Analyzer
The ETI-MAX 3000 is a fully automated microtiter plate analyzer performing the complete sample proce (more)ssing (sample pre-dilutions, sample and reagent dispensing, incubations, wash processes, plate transports) as well as the photometric measurement and evaluation. The instrument is controlled by Windows PC software. This software allows the user to process the pre-defined assays of DiaSorin as well as assays programmed by the user. The clear structure with intuitive user-guidance allows simple and quick operation of daily routine jobs as well as programming of user-specific assays. Liquid handling: 1 ml thinner Disposable tips: 300 or 1100 µl Pipette range: Simultaneous operation of 4 plates Precision (samples and reagents): CV < 8.0% at 10 µl, CV < 2.5% at 100 µl Level sensor: Electronic Clot detection: Yes Mixing: Yes (pre-dilution tube and microplate) Multipipetting: Yes (sample, control and reagent) Pipetting time samples: < 18 min/96 wells (100 µl/well) Pipetting time reagents: < 4 min/96 wells (100 µl/well) Carry-over: None Identification: Barcode scanner for primary vessels, controls and reagents, Barcode scanner for microtiter plates Tube: Diameter 10-16 mm, Height 55-100 mm Barcode type: 2/5 interleaved, UPC A & E, 2/5 IATA, 2/5 Industrial, EAN 8 of 13, Code 128, EAN 128, Pharmacode, EAN addendum, 2 of 5, Code-a-bar Capacity: Maximum 240 sample tubes Capacity: 4 separate incubators Temperature range: 5°C above room temperature to 50°C Accuracy: ± 1°C average of the plate Consistency: ± 0.7°C/whole plate Shaking: Lengthwise Capacity: Up to 4 wash buffers Wash head: 1 x 8 Pipette volume: 200 – 2500 µl/well, depending on the assay Precision: ± 5% CV at 300 µl Residual volume: < 2.5 µl in round-bottom wells, < 4 µl for flat-bottom wells Level sensor buffer: Yes Level sensor waste container: Yes Wash programs: 1 to 9, depending on the assay Incubation time: 1 to 999 seconds, depending on the assay Pipette pressure: Adjustable for each assay individually Measurement: Vertical with photodiodes, Extinction or kinetic measurement Channels: 8 Operation: Single or double, with second measurement when the measuring range is exceeded Spectrum: 400 – 700 nm Filter: Up to 8 positions are available, of which 5 are already on board (405, 450, 492, 550, 620 nm) Measurement time: < 10 seconds Dynamic range: – 0.100 to 3,000 absorption units Linearity: 0 –2,000 absorption units ± 1.0% Precision: ± 0.005 absorption units or 2.5% Dimensions (WxDxH): 1130 x 760 x 1000 mm Weight: 130 kg
€2,500.00 ex VAT
Netherlands
automated liquid handling, microplate readers