Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
New Era Pump Systems
Model
New Era Pump Systems NE-1600 Six-Syringe Pump
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
used
Categories

NE-1600 Six-Syringe Pump

Biomatyx
item image

Description by the supplier

New Era Pump Systems NE-1600 Six-Syringe Pump

Model: NE-1600

Syringe sizes: NE-1600 Up to 140ml in 4 channels or 60mL in 6 channels

Number of Syringes: Six

Voltage: 220 Volts with Included 12VDC Power Adapter

Maximum Speed: 3.4917 cm/min

Maximum pumping rate: 1163 mL/hr with a B-D 60 cc syringe

Dimensions: 10 1/4” x 15” x 5” High

Syringe Size Maximum Rate Minimum Rate

0.5 µL 17.45 µL/hr 0.001 µL/hr

1 mL 36.19 mL/hr 0.452 µL/hr

3 mL 153.2 mL/hr 1.914 µL/hr

5 mL 255 mL/hr 3.185 µL/hr

10 mL 415.9 mL/hr 5.195 µL/hr

20 mL 661.4 mL/hr 8.26 µL/hr

30 mL 862.8 mL/hr 10.78 µL/hr

60 mL 1451 mL/hr 18.1 µL/hr

140 mL 2376 mL/hr 29.7 µL/hr

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
People are watching right now:
Agilent 7820A GC-cover
Agilent 7820A GC

For sale: Refurbished Agilent 7820A GC system including: Prices from: 7.000 till 10.000 euro (please (more) ask for official quote) Look like new 7820A GC Split/splitless inlet FID Detector Chemstation software Computer Optional: autoinjector Test report   Also available: Agilent 7890A GC Agilent 6890N GC Agilent 7890B GC   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! Prices from: 7.000 till 10.000 euro (please ask for official quote) Look like new 7820A GC Split/splitless inlet FID Detector Chemstation software Computer Optional: autoinjector Test report   Also available: Agilent 7890A GC Agilent 6890N GC Agilent 7890B GC   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! We can deliver maintenance and repair services for Agilent GC, HPLC, GC/MS, LC/MS by our own engineers   7820A GC System The 7820A Gas Chromatograph system performs great day-to-day analysis. The system provides reliable capabilities for a wide range of application areas, meeting regulatory and SOP needs for small-to medium-sized labs. Runs with full electronic pneumatic control (EPC) from inlet to detector for good retention time and area count performance. Electronic pneumatic regulation (EPR) offers manual operation simplicity with high precision digital display of pressure/flow. Superior ease-of-use over traditional systems. Features Retention Time Locking (RTL) provides improved data consistency by maintaining exact retention times from injection to injection, column to column, instrument to instrument, and lab-to-lab Electronic Pneumatics Regulation (EPR) provides the simplicity of manual operation with high-precision digital display of pressure/flow and superior ease-of-use, compared to traditional manual pneumatics systems Great fit for routine applications using a single quadrupole mass spectrometer Single filament TCD doesn’t require a separate reference gas or manual potentiometer adjustment and provides a stable baseline without drift Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injectio nOther detectors include FPD plus, NPD, and µECD Inlets options include split/splitless, packed, purge packed, and on-column inlets Valve configurations that include up to three valves Full electronic pneumatic control (EPC) from inlet to detector Simplified GC front panel keys and display provide sequence information, instrument conditions,and run status, and minimize operating errors Software keyboard and display allows the user to control the system when it connects with an integrator or 3rd-party software

Netherlands
gc systems
WATERS ALLIANCE 2695 + 2487 DAD HPLC-cover
WATERS ALLIANCE 2695 + 2487 DAD HPLC

For sale: Refurbished WATERS ALLIANCE 2695 HPLC Pricing: from EUR 9500,- till EUR 12.000,-  (please  (more)ask for official quote) Refurbished including:  2695 module  2487 Dual Absorbance Detector DAD  Software and computer Cables and connectors Also available: Other type of Detectors available like PDA Other brands of HPLC like Agilent and Thermo More refurbished parts for Waters HPLC systems All our products are fully tested and delivered with warranty   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! Waters 2695 HPLC System Specifications Number of solvents One to four Solvent conditioning Vacuum degas, two (2) operating modes, four (4) chambers, ≈<500 uL internal volume per chamber> <500uL interval volume per chamber Programmable flow rate range 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. increments Typical operating flow rate range 0.050 to 5.000 mL/min in 0.001-mL/min increments Compressibility compensation Automatic and continuous Effective system delay volume <650 µL, independent of backpressure @ 1 mL/min Plunger seal wash Integra, active, programmable Gradient profiles Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] Dry prime/wet prime Automatic, front panel control Flow ramping Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate Maximum operating pressure 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min. Pressure ripple ≤2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure) Composition accuracy ±0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm]) Composition precision ≤0.15% RSD or ≤0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) Flow precision ≤0.075% RSD or ≤0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix Flow accuracy ±1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure

Netherlands
hplc systems
Waters 2475 Multi-Wavelength Fluorescence Detector-cover
Waters 2475 Multi-Wavelength Fluorescence Detector

For sale: refurbished Waters 2475 Multi-Wavelength Fluorescence Detector   Also available: Waters 26 (more)95 Alliance HPLC systems Other Waters Detectors Parts for 2475 detector Complete Waters HPLC systems   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! We can deliver maintenance and repair services for Waters Alliance systems by our own engineers   The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 FLR Detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, and has the ability to monitor up to four independent wavelength pairs.   Features: Innovative axially illuminated flow cell designed for less dispersion, less stray light, less volume, and more pathlength for maximum sensitivity Three-dimensional spectral scanning for faster method development and optimization, and enhanced peak identification Single or multi-channel operation monitors fluorescence at one or more discrete wavelength pairs Low noise performance – Less stray light due to orthogonal optics and the use of mirrors, not lenses, minimize scatter Multiple detection modes – 2D, 3D, and on-the-fly spectral scanning – can greatly reduce the time needed to develop fluorescence detection methods by quickly determining wavelength maxima Integral erbium calibration reference – ensures wavelength accuracy Normalized emission units for better bench-to-bench reproducibility Attribute Specification Wavelength range Ex: 200 to 890 nm Em: 210 to 900 nm Bandwidth 20 nm (maximum) Wavelength accuracy +3 nm Wavelength repeatability +0.25 nm Sensitivity, single channel  Ex: 350 nm Em: 397 nm (Single-to-noise ratio of water Raman peak >1000. Hamming filter TC = 1.5 sec) Sensitivity setting range 1 to 100,000 EUFS Filter setting range Side-channel: 0.1 to 5.0 seconds, Hamming (default) 0.1 to 99 seconds, RC multichannel: 1 to 50 seconds, hamming (default) 1 to 99 seconds, RC

€4,500.00 ex VAT
Netherlands
optical detectors
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717