Pfeiffer MVP 070-3 Diaphragm Pump

$6,510.00 (ex VAT)
item image

Description from the supplier

  • Diaphragm pump with a pumping speed of up to 4.3 m3/h
  • No hydrocarbons: Completely dry & oil-free diaphragm pump
  • Low noise level, minimal vibrations and compact design, ideal also for use in laboratories
  • Low operating costs thanks to the highest quality, short maintenance times and long maintenance intervals
  • Simple logistics: Our diaphragm pumps are suitable for all voltages worldwide
  • Fulfills cleanroom class ISO 8 (according to DIN EN ISO 14644-1)

The Pfeiffer MVP 070-3 Diaphragm Pump is an advanced, oil-free solution engineered to deliver reliable, clean vacuum performance without hydrocarbons. With a maximum pumping speed of 3.8 m³/h at 50 Hz and 4.3 m³/h at 60 Hz, this pump is built for optimal efficiency in diverse lab applications. Designed with a final pressure of 1 hPa / 0.75 Torr / 1 mbar, the MVP 070-3 ensures precise vacuum control while maintaining an exceptionally low integral leak rate of 0.002 Pa m³/s, minimizing contamination risks. Certified to meet cTUVus standards under UL / CSA 61010-1 and protected by an IP40-rated enclosure, this pump meets rigorous safety requirements and offers robust performance across a wide range of applications.

Supporting versatile input voltages (100–115 / 200–230 V AC at 50 Hz and 100–115 / 120 / 200–230 V AC at 60 Hz) with a ±10% tolerance, the MVP 070-3 is well-suited for global use. It operates with a noise level of only 52 dB(A) (EN ISO 2151), ensuring a quiet laboratory environment, while its air-forced convection cooling method maintains optimal operation. Featuring compact G ¼'' connection flanges, a max intake and exhaust pressure of 1,100 hPa, and a lightweight build of 16.4 kg, this diaphragm pump offers easy integration into lab setups. With no gas ballast needed, the MVP 070-3 promises efficient, maintenance-friendly operation, perfect for labs requiring clean, reliable, and durable vacuum systems.

  • Silencer
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Product details

Pumping speed at 50 Hz3.8 m 3/h / 2.23668 cfm / 63.3346 l/min
Pumping speed at 60 Hz4.3 m 3/h / 2.53098 cfm / 71.6681 l/min
Final pressure1 hPa / 0.75 Torr / 1 mbar
Integral leak rate0.002 Pa m 3/s / 0.266 Torr l/s / 0.2 mbar l/s
Intake pressure max.1,100 hPa / 825 Torr / 1,100 mbar
Exhaust pressure, max.1,100 hPa / 825 Torr / 1,100 mbar
Connection flange (in)G ¼''
Connection flange (out)G 1/4"
Input voltage: tolerance±10 %
Motor type1-phase motor
Protection degreeIP40
CertificationcTUVus certified according to UL / CSA 61010-1
SwitchYes
Emission sound pressure level (EN ISO 2151)52 dB(A)
Ambient temperature10 – 40 °C
Temperature: Storage-10 – 60 °C
Temperature: Shipping-10 – 60 °C
Cooling methodAir (Forced convection)
Weight16.4 kg / 36.16 lb
Gas ballastNo
Operating altitude, max.2,000 m
Input voltage(s)100 – 115 / 200 – 230 V AC, 50 Hz / 100 – 115 / 120 / 200 – 230 V AC, 60 Hz
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Edwards nEXT240T HC - CF100 160W Turbomolecular Pump-cover
Edwards nEXT240T HC - CF100 160W Turbomolecular Pump

Edwards nEXT240T HC - CF100 160W Turbomolecular Pump Ultimate Vacuum <5x10-10 mbar Inlet Connecti (more)on DNISO100-K Pumping Speed Nominal 1439.99 l/min Features - Combines oil-lubricated ceramic lower bearing with a dry permanent magnetic upper bearing for improved performance - Offers direct I/O or serial control; compatible with TAG and TIC controllers for system integration - Oil cartridge and bearings can be replaced in the field with minimal tools - Features multiple drag stages for enhanced compression ratios and increased backing pressure tolerance - Suitable for a variety of demanding applications including high-energy physics, electron microscopy and industrial development - Features a patented bearing suspension system to reduce noise and vibration transmission to the vacuum system - Includes a purge port for safe operation with specialized gases - The permanent magnet upper bearing ensures a hydrocarbon-free environment, reducing contamination The nEXT is a hybrid bearing compound turbomolecular pump. nEXT pumps combine our proven bearing technology (oil lubricated ceramic lower bearing with dry permanent magnetic upper bearing), an improved rotor design with a new molecular drag stage to deliver improved pumping speed and compression ratios, and user serviceability. They feature 24 V to 48 V DC sensorless motors with a built-in drive that is fully compatible with our range of TAG and TIC controllers.INCLUDED: The Edwards nEXT240T HC - CF100 160W Turbomolecular Pump includes: - Power Cord - One Year Manufacturer's Warranty

$10,327.00 ex VAT
United States
pumps liquid & other
People are watching right now:
Laboport SC 820 G KNF vacuum pump system-cover
Laboport SC 820 G KNF vacuum pump system

Chemical resistant vacuum pump consisting of N 820 G diaphragm vacuum pump, support base, a separato (more)r on the suction side, a high-performance condenser on the pressure side and the Wifi device for remote vacuum control. Thanks to the high compatibility of steam and condensate, the system is perfectly suited for extremely aggressive / corrosive gases and vapors. Technical features Flow rate (max.): 20 l/min Final vacuum (max.): 6 mbar (abs.) Pressure (max.): 0.1 bar (rel.) Flow rate (m³/h) at atm. pressure: 1,2 Permissible fluid temperature between 5 and 40°C Valve material: FFPM Diaphragm material: PTFE coated Pump head material: TFM ™ PTFE Application Vacuum oven Distillation Rotary evaporation Multi-user vacuum systems Qualitative characteristics Automatic and accurate recognition and monitoring of the boiling point via the integrated ramp function High recovery rates even with low boiling point solvents Wifi control device for safe operation from the outside of closed fume hoods Vacuum system comprising chemically resistant diaphragm vacuum pump, base plate, separator on suction side and high performance condenser on pressure side Modular expandable 100% oil-free transfer Thereby pure transferring, evacuation and compression of gases High level of vapor and condensate compatibility Ideal for extremely aggressive / corrosive gases and vapors Integrated gas ballast valve 3-color status display for in operation / stand-by / error Integrated rotational speed control Environmentally friendly Start against ultimate vacuum of the pump Download the data sheet for further information and accessories. NOT SURE WHICH VACUUM PUMP YOU NEED? Try following our guide to KNF pumps: VACUUM PUMPS FOR THE LABORATORY Or download the KNF guide: THE IDEAL DIAPHRAGM PUMP FOR EVERY APPLICATION

€4,919.00 ex VAT
€5,853.61 incl. VAT if applicable
Italy
pumps liquid & other, vacuum pumps
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction X-ray Generator System This system was remo (more)ved from a university lab where it was surplus to requirements. The system is in very good cosmetic condition, but several units encountered issues during testing, and no PC or control software is included. As such, the system is listed for spares/repair. - Further information regarding issues faced are stated below. The lab stated it had been not used for some time but had some issues. The system units include: - Oxford Diffraction Xcalibur PX Ultra - Serial No.: XXH-127/05 - Year: 2005 - Powered on with mains light, Shutter Closed status light, inner display screen, and hand-held remote keypad all functioning - Oxford Diffraction X-ray Protection Cabinet - Serial No.: XPD-127/05 - Year: 2005 - Thermo Scientific Neslab ThermoFlex 10,000 Recirculating Chiller - Serial No.: 1111473501170217 - Powered on but shut off after 1 second with error code "PHEr" (limit fault) - Oxford Diffraction KMW200CCD CCD Detector Chiller Unit - Serial No.: CCA 73/06 - Year: 2006 - Powered on, but no further testing possible - Oxford Diffraction KMC3000C X-ray Tube Chiller - Serial No.: CAC-142/05 - Year: 2005 - Powered on, pump ran, thermostat seemed functional, but not fully tested - Oxford Diffraction Cryodrive 2.0 - Serial No.: R72-0558 - 6944 running hours - Powered on, but no further testing without gas supply - Oxford Cryosystems Cobra Controller 700 Series Cold Head Controller - Serial No.: 741174 - Powered on, displayed ambient temperature, status lights, and responsive buttons - Parker NitroFlowLab Nitrogen Generator - Model No.: 4278 - Serial No.: 4278-13NFLC0008 - Powered on, displayed a message "writing information to an SD card," and did not allow further actions - Oxford Cryosystems Standard Cobra Nitrogen Control Pump - Serial No.: CB171 - Agilent HS 602 Vacuum Pump with NW25 Oil Exhaust Filter - Model: 849-9365R001 - Serial No.: 232830 - Year: 2006 - Produced a vacuum but failed a PAT test on insulation Additional notes: - All units passed a PAT test except for the Agilent vacuum pump, which failed due to insulation issues. - The Xcalibur unit and Neslab chiller were only visually tested due to larger power plugs. Manuals included: - Oxford Instruments Object Bench Software handbook - Xcalibur Series user manual - Thermo Scientific Recirculating Chiller Operation, Installation, and Maintenance manual - Oxford Diffraction KMC3000C user manual - Oxford Cryosystems Cobra operation guide - Safety Matters cryogenic safety manual - 2 x CrysAlis Pro user manuals - Oxford Instruments Cryojet Controller UMC002 manual - Workstation 4 VMware v4.52 Virtual Machine Software and manual Accessories included: - 1 x set of keys for safety cabinet - 1 x Long Fine Focus unit (Type OD2773/00, No. 163054) - 3 x glass vacuum traps (2 litres approx.) - 2 x vacuum pump platforms - 2 x Parker wound filter cartridges (Part No.: M11R10A) - 2 x Agilent KMW3000 filter cartridges (Part No.: IJ-00-01-002) - 1 x carbon filter nitroflow mobile - 6 x data cables - 4 x Cobra stainless steel line drier units - 1 x 4-way valve purge block - 1 x box of stainless armoured hose pipe and 1/4" plastic tubing

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]