Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
KNF
Location
Hampton - United States
Price
$1,795.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

KNF IP65 UFEM 1.10 KT.18S2 Liquid Pump

$1,795.00 (ex VAT)
item image

Description from the supplier

KNF IP65 UFEM 1.10 KT.18S2 Liquid Pump
KNF SIMDOS diaphragm pumps offer a variety of options to suit most laboratory liquid metering and dosing needs. The UFEM 1.10 KT.18S2 version has a liquid transfer flow rate of 1 – 100 mL/min and discreet dosing volumes of 1– 999 mL. It is constructed with the following chemically-resistant flow path materials: PP head, PTFE covered diaphragm, and FFKM valves. The easy-to-read display combined with a touch control knob makes programming and access of all functions very intuitive.

  • Power Cord
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Product details

Liquid Flow Rate1 – 100mL/min
Liquid Dosing Volume1 – 999mL
Weight2.0 lbs., 0.9 kg
Connection Tubing ID1/4 in. OD x 1/8 in. ID, 6mm x 4mm
Permissible Gas and Ambient Temperature Range5°C to 40°C
Permissible Liquid Media Temperature Range5°C to 80°C
Pump HeadPP
DiaphragmPTFE covered
ValvesFFKM
Dimensions (L x H x W)5.7 x 5.9 x 3.7 in. (144 x 150 x 93 mm)
Maximum Suction9.8 ft. H2O
Maximum Pressure85 psig, 6.0 bar
Power Consumption24 W
FunctionsS2
Electrical100 – 240V
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Wet gas vacuum pump Laboport SD N 820.3 FT.40.18 KNF-cover
Wet gas vacuum pump Laboport SD N 820.3 FT.40.18 KNF

The N 820.3 FT.40.18 is a two-stage pump with an integrated “self-drying” system for automatic conde (more)nsate drain. The “SD” series is widely used in laboratories, especially when the vapors are humid and a clean and ecological vacuum is required. Typical applications are: vacuum ovens (for drying chemicals, drying biological samples, heat treatments), autoclaves for sterilizing instruments, containers, filters and textiles. Thanks to the use of anti-corrosion materials, it is possible to vacuum even corrosive products.  The heart of the pump is the diaphragm with differentiated structure in PTFE, optimized to guarantee high performance with reduced dimensions and at the same time, long life even in heavy applications.  When the humid gases are sucked in, condensation may form in the pump head: consequently the performance decreases, considerably increasing the emptying time. To eliminate condensation, the 'drying system' then opens a solenoid valve that allows ambient air to enter the heads. Once the condensation has been eliminated, the solenoid valve closes and the pump sucks from the stove in full capacity. Over time, condensation could form again and then the cycle is repeated. The time interval between one cycle and the next can be adjusted as desired, as well as the duration of the air injection. Technical features Flow rate (max.) 20 l / min Final vacuum (max.) 10 mbar (abs.) Pressure (max.) 1 bar (rel.) Fluid temperature allowed at 5-40°C FFPM valve material PTFE coated diaphragm material Pump head material PTFE Applications Rotary evaporation Vacuum oven Qualitative characteristics Clean operation, 100% oil-free Corrosion resistant PTFE / FFPM flow path Ideal for extremely aggressive / corrosive gases and vapors Compact, silent and reliable The self-drying system removes condensation without altering the vacuum level Maintenance free Download the data sheet for further information and accessories. NOT SURE WHICH VACUUM PUMPS YOU NEED? Try following our guide to KNF pumps: VACUUM PUMPS FOR THE LABORATORY Or download the KNF guide: THE IDEAL DIAPHRAGM PUMP FOR EVERY APPLICATION

€1,990.00 ex VAT
€2,368.10 incl. VAT if applicable
Italy
pumps liquid & other, vacuum pumps
Edwards nEXT400D - CF160 160W Turbomolecular Pump-cover
Edwards nEXT400D - CF160 160W Turbomolecular Pump

Edwards nEXT400D - CF160 160W Turbomolecular Pump Ultimate Vacuum <1x10-10 mbar Inlet Connection  (more)DN160CF Pumping Speed Nominal 24,000.00 l/min Features - Combines oil-lubricated ceramic lower bearing with a dry permanent magnetic upper bearing for enhanced performance - Features built-in electronics for easy integration with TAG and TIC controllers - Allows for in-field oil and bearing cartridge changes with minimal tools - Provides high speeds and compression with advanced simulation-derived designs - Features a patented bearing suspension system to minimize noise and vibration - Ensures a clean vacuum with a permanent magnet upper bearing - Suitable for research, high-energy physics, mass spectrometry, and industrial applications - Designed for long-term reliability and minimal maintenance needs nEXT turbomolecular pumps are hybrid bearing pumps with integrated controllers for pumping speeds from 47 to 1250 ls-1.The nEXT is a hybrid bearing compound turbomolecular pump. nEXT pumps combine our proven bearing technology (oil lubricated ceramic lower bearing with dry permanent magnetic upper bearing), an improved rotor design with a new molecular drag stage to deliver improved pumping speed and compression ratios, and user serviceability. They feature 24 V to 48 V DC sensorless motors with a built-in drive that is fully compatible with our range of TAG and TIC controllers.Features and Benefits - Upper magnetic bearing - ensures clean vacuum, low power and low vibration. - Optimised rotor designs - deliver high speeds and high compression. - Range of variants suitable for many applications - D = standard nEXT pump variant, H = optimised rotor design for high light gas compression and T = additional regenerative stage for increased compression and higher backing pressure capability - Integrated controller / electronics - offers direct I/O or serial control or can be connected to one of our TAG or TIC controllers for easy systemisation. - Fully user serviceable - oil cartridge and bearings can be changed in the field with minimal tooling. - Inlet screen - supplied as standard INCLUDED: The Edwards nEXT400D - CF160 160W Turbomolecular Pump includes: - Power Cord - One Year Manufacturer's Warranty

$13,931.00 ex VAT
United States
pumps liquid & other
People are watching right now:
Radwag MA 50/1.5Y.IC Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]