Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Busch Produktions GmbH
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€550.00 
(€654.50 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight:

Categories

Busch RA 0040 F 505 B Vakuumpumpe 0.1 hPa (mbar)

PROFCONTROL GmbH€550.00 
(€654.50 incl. VAT* )* - if applicable
item image

Description by the supplier

MORE DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Yamato GLD202BB Rotary Vane Vacuum Pump with Stainless Steel Hose, 115V-cover
Yamato GLD202BB Rotary Vane Vacuum Pump with Stainless Steel Hose, 115V

Yamato GLD202BB Rotary Vane Vacuum Pump with Stainless Steel Hose, 115V Ultimate Pressure 6.7 x 10 (more)-3 mbar Actual Pumping Speed 200 L/min (50Hz) 240 L/min (60Hz) Weight 31 kg Features - High performance while maintaining low vibration and noise levels - Oil-back flow prevention mechanism - Large sized oil level gauge to ensure accuracy in monitoring vacuum processes - Multi voltage motor - Compatible with a variety of applications Introducing the GLD Series Rotary Vane Pump, a high-performance and low-noise vacuum pump designed to excel in various applications. This pump boasts an array of impressive features, including a gas ballast valve, oil-back-flow prevention mechanism, and a generously sized oil level gauge. With its multi-voltage motor and adherence to international standards, it ensures versatility and compatibility across different setups. Perfectly suited for applications in the fields of chemistry, scientific experimentation, analyzers, and laser systems, this pump also excels as a backing pump for electronic microscopes, semiconductor equipment, sputtering and vacuum evaporation equipment, as well as vacuum and freeze dryers. Plus, with a noise level of just 57 db(A) or less, it ensures a quiet and efficient operation. Experience superior performance and reliability with the GLD Series Rotary Vane Pump, your ideal choice for vacuum solutions.INCLUDED: The Yamato GLD202BB Rotary Vane Vacuum Pump with Stainless Steel Hose, 115V includes: - Hose Clamp - NW25 Centering O-Ring - SUS Flexible Hose KF25 x 1500mm - Oil Mist Trap - Power Cord - One Year Manufacturer's Warranty

$4,493.00 ex VAT
United States
pumps liquid & other, vacuum pumps
Polyscience CA10A3P2-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C 2900W 230VAC-cover
Polyscience CA10A3P2-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C 2900W 230VAC

Polyscience CA10A3P2-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C 2900W 230 (more)VACFeatures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA10A3P2-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C 2900W 230VAC is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA10A3P2-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C 2900W 230VAC SpecificationsPart NumberCA10A3P2-41AA1NCooling Capacity @ 20°C2.9 kWCooling Capacity @ 10°C1.93 kWCooling Capacity @ 0°C1.0 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate3.5 gpm / 13.2 lpmPower Requirements230V, 60HShipping Weight177 lbs / 80.3 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(8) { background-color: #fffacd; }

$8,794.00 ex VAT
United States
chillers, heating & cooling, pumps liquid & other
People are watching right now:
Yamato SM-301 Sterilizer with Dryer 32L, 115V-cover
Yamato SM-301 Sterilizer with Dryer 32L, 115V

Yamato SM-301 Sterilizer with Dryer 32L, 115V Operating Temperature Sterilization 105°C to 128°C Op (more)erating Temperature Drying 150°C to 180°C Internal Capacity 32L Features - Automatic operations from sterilization to drying carried out with an interactive key input system - Quick sample drying capability makes samples ready to use right after sterilization - Drying temperature can be set according to sample material, quantity, etc. - Timer range from 1~999 hours - Drain bottle water level can be quickly confirmed on the front panel level indicator - Drain valve located in front for easy access - Absence of protrusions in sterilization chamber makes insertion & removal of baskets, and other items quick and easy - Self-diagnostic functions make operation safer and error recovery quicker - Condensation collector neutralizes high temperature exhaust steam safely High performance, fully automatic 32L standard steam sterilization from start to finish with high pressure steam sterilization and drying steps. Automatic operations from sterilization to drying carried out with an interactive key input system. Quick sample drying capability makes samples ready to use right after sterilization. Drying temperature can be set according to sample material, quantity, etc. Timer range from 1~999 hours. Drain bottle water level can be quickly confirmed on the front panel level indicator. Drain valve located in front for easy access. Absence of protrusions in sterilization chamber makes insertion & removal of baskets, and other items quick and easy. Self-diagnostic functions make operation safer and error recovery quicker. Condensation collector neutralizes high temperature exhaust steam safely. Sterilizing temp. range 105 to 128°C. Drying temp range 150 to 180°C. INCLUDED: Yamato SM-301 Sterilizer with Dryer 32L, 115V includes: - 2 pcs. stainless steel mesh basket (⌀266 x D204 mm) - Drain board, drain bottle, condensation collection container with magnetic bracket - Power Cord - Operator's Manual - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$7,694.00 ex VAT
United States
autoclaves or sterilizers
Radwag MA 50.5Y.NS Moisture Analyzer-cover
Radwag MA 50.5Y.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,390.00 ex VAT
Poland
balances, moisture analysers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]