Waters 2475 Multi-Wavelength Fluorescence Detector

Lab2€4,500.00 (ex VAT)
item image

Description by the supplier

For sale: refurbished Waters 2475 Multi-Wavelength Fluorescence Detector

 

Also available:

Waters 2695 Alliance HPLC systems

Other Waters Detectors

Parts for 2475 detector

Complete Waters HPLC systems

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

We can deliver maintenance and repair services for Waters Alliance systems by our own engineers

 

The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 FLR Detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, and has the ability to monitor up to four independent wavelength pairs.

 

Features:

Innovative axially illuminated flow cell designed for less dispersion, less stray light, less volume, and more pathlength for maximum sensitivity

Three-dimensional spectral scanning for faster method development and optimization, and enhanced peak identification

Single or multi-channel operation monitors fluorescence at one or more discrete wavelength pairs

Low noise performance – Less stray light due to orthogonal optics and the use of mirrors, not lenses, minimize scatter

Multiple detection modes – 2D, 3D, and on-the-fly spectral scanning – can greatly reduce the time needed to develop fluorescence detection methods by quickly determining wavelength maxima

Integral erbium calibration reference – ensures wavelength accuracy

Normalized emission units for better bench-to-bench reproducibility

Attribute

Specification

Wavelength range

Ex: 200 to 890 nm

Em: 210 to 900 nm

Bandwidth

20 nm (maximum)

Wavelength accuracy

+3 nm

Wavelength repeatability

+0.25 nm

Sensitivity, single channel 

Ex: 350 nm

Em: 397 nm

(Single-to-noise ratio of water Raman peak >1000. Hamming filter TC = 1.5 sec)

Sensitivity setting range

1 to 100,000 EUFS

Filter setting range

Side-channel:

0.1 to 5.0 seconds, Hamming (default)

0.1 to 99 seconds, RC

multichannel:

1 to 50 seconds, hamming (default)

1 to 99 seconds, RC

About Lab2

LAB2 is specialized in refurbishment or used analytical instruments of the major brands, like Agilent Tech, Thermo, Waters, Shimadzu, Perkin Elmer, CTC Analytics, Varian and more. Through the years we have developed into one of the most reliable partners worldwide.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Waters 2475 Multi-Wavelength Fluorescence Detector-cover
Waters 2475 Multi-Wavelength Fluorescence Detector

For sale: refurbished Waters 2475 Multi-Wavelength Fluorescence Detector   Also available: Waters 26 (more)95 Alliance HPLC systems Other Waters Detectors Parts for 2475 detector Complete Waters HPLC systems   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! We can deliver maintenance and repair services for Waters Alliance systems by our own engineers   The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 FLR Detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, and has the ability to monitor up to four independent wavelength pairs.   Features: Innovative axially illuminated flow cell designed for less dispersion, less stray light, less volume, and more pathlength for maximum sensitivity Three-dimensional spectral scanning for faster method development and optimization, and enhanced peak identification Single or multi-channel operation monitors fluorescence at one or more discrete wavelength pairs Low noise performance – Less stray light due to orthogonal optics and the use of mirrors, not lenses, minimize scatter Multiple detection modes – 2D, 3D, and on-the-fly spectral scanning – can greatly reduce the time needed to develop fluorescence detection methods by quickly determining wavelength maxima Integral erbium calibration reference – ensures wavelength accuracy Normalized emission units for better bench-to-bench reproducibility Attribute Specification Wavelength range Ex: 200 to 890 nm Em: 210 to 900 nm Bandwidth 20 nm (maximum) Wavelength accuracy +3 nm Wavelength repeatability +0.25 nm Sensitivity, single channel  Ex: 350 nm Em: 397 nm (Single-to-noise ratio of water Raman peak >1000. Hamming filter TC = 1.5 sec) Sensitivity setting range 1 to 100,000 EUFS Filter setting range Side-channel: 0.1 to 5.0 seconds, Hamming (default) 0.1 to 99 seconds, RC multichannel: 1 to 50 seconds, hamming (default) 1 to 99 seconds, RC

€4,500.00 ex VAT
Netherlands
optical detectors
People are watching right now:
LAUDA ECO RE 415 S Cooling Thermostat-cover
LAUDA ECO RE 415 S Cooling Thermostat

ECO Silver Lauda - Cooling Thermostat LAUDA ECO with reliable technology and modern design for tempe (more)rature ranges from -50°C to 200°C depending of the models. Microprocessor management and integrated cooling system. Silver (monochromatic LCD graphic display), both equipped with mini USB interface. They are distinguished by their range of functions, ease of use and clarity of the display, allowing maximum comfort of use for the operator. These models offer the highest performance conveyed by the LAUDA SmartCool intelligent system, for maximum energy savings. The circulation pump can be adjusted to six levels and the comprehensive range of ECO devices offers cooling capacities from 180 to 700 watts. Refrigerated thermostats comes standard with tank lid, pump connections and are available with air and water cooling. A drain cock on the back of the device makes changing the liquid in the tank easy and safe.Thermostatic bath/circulator with latest microprocessor technology and integrated cooling system MAIN FEATURE • Monochrome grafic LCD display for simultaneous indication of actual and set value • User friendly menu navigation in plain language • Easy input via cursor and soft keys. Additional Tmax key for overtemperature protection • Fully electronic continuous controller with PID action • Safety class III for operation with flammable and non-flammable liquids. Overtemperature cut-out adjustable via menu • Vario pump with six adjustable performance levels • Easy control of the flow rate between internal and external circulation during operation without contact with the bath • USB interface as standard • Upgradeable with an interface module (analogue module, contact module, RS 232/485 module, Profibus, Ethernet-USB module) • Upgradeable with Pt 100/LiBus module for external control and remote control via Command console • Integrated programmer, 1 programme with max. 20 segments • Pump connectors with plastic nipples 13 mm as standard • Bath vessel made from stainless steel with drain valve • Condenser cooling Air • Utilizes natural refrigerants Graph of cooling performance of ECO Silver LAUDA cryostats. Performance graph of the pump pressing on the six levels. TECHNICAL VISUALIZATION Display 1 - Status display 2 - Display of the internal or external temperature value (T-int or T-ext) 3 - Soft-key bar Control panel 4 - Soft keys, left and right 5 - Enter key 6 - Cursor keys for Up, Down, Left and Right. 7 - T max key: display and adjustment of the overtemperature switch-off point 1 - USB interface 2 - Upper module receptacle approx. 51 mm x 27 mm for analog, RS 232/485 module, Profibus module and contact module 3 - Lower module receptacle approx. 51 mm x 17 mm for Pt100/LiBus module 4 - Connection socket 75S for control cable of cooling underpart for RE 1050 S 5 - Rating label 6 - Connection socket 51H for power supply between the control head and cooling underpart 7 - Mains connecting lead 1 - Pump connection: Outflow and return with fittings 13 mm diameter (plastic) 2 - Bath cover 3 - Front grip recess 4 - Ventilation grill (both sides) 5 - Front panel (removable without tools) 6 - Four feet 1 - Rating label 2 - Control cable of cooling underpart (only with RE 1050 S) 3 - Rear grip recess 4 - Connecting lead between the control head and cooling underpart 5 - Bath draining tap 6 - Bath drain point 7 - Ventilation grill

€4,048.00 ex VAT
€4,817.12 incl. VAT if applicable
Italy
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]