Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Waters
Model
Waters 2475 Multi-wavelength
Supplier
Lab2
Location
Berkel en Rodenrijs - Netherlands
Price
€4,500.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Waters 2475 Multi-Wavelength Fluorescence Detector

Lab2€4,500.00 (ex VAT)
item image

Description by the supplier

For sale: refurbished Waters 2475 Multi-Wavelength Fluorescence Detector

 

Also available:

Waters 2695 Alliance HPLC systems

Other Waters Detectors

Parts for 2475 detector

Complete Waters HPLC systems

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

We can deliver maintenance and repair services for Waters Alliance systems by our own engineers

 

The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 FLR Detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, and has the ability to monitor up to four independent wavelength pairs.

 

Features:

Innovative axially illuminated flow cell designed for less dispersion, less stray light, less volume, and more pathlength for maximum sensitivity

Three-dimensional spectral scanning for faster method development and optimization, and enhanced peak identification

Single or multi-channel operation monitors fluorescence at one or more discrete wavelength pairs

Low noise performance – Less stray light due to orthogonal optics and the use of mirrors, not lenses, minimize scatter

Multiple detection modes – 2D, 3D, and on-the-fly spectral scanning – can greatly reduce the time needed to develop fluorescence detection methods by quickly determining wavelength maxima

Integral erbium calibration reference – ensures wavelength accuracy

Normalized emission units for better bench-to-bench reproducibility

Attribute

Specification

Wavelength range

Ex: 200 to 890 nm

Em: 210 to 900 nm

Bandwidth

20 nm (maximum)

Wavelength accuracy

+3 nm

Wavelength repeatability

+0.25 nm

Sensitivity, single channel 

Ex: 350 nm

Em: 397 nm

(Single-to-noise ratio of water Raman peak >1000. Hamming filter TC = 1.5 sec)

Sensitivity setting range

1 to 100,000 EUFS

Filter setting range

Side-channel:

0.1 to 5.0 seconds, Hamming (default)

0.1 to 99 seconds, RC

multichannel:

1 to 50 seconds, hamming (default)

1 to 99 seconds, RC

About Lab2

LAB2 is specialized in refurbishment or used analytical instruments of the major brands, like Agilent Tech, Thermo, Waters, Shimadzu, Perkin Elmer, CTC Analytics, Varian and more. Through the years we have developed into one of the most reliable partners worldwide.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Agilent 1260 Fluorescence Detector-cover
Agilent 1260 Fluorescence Detector

Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Firmware A.07.02 8 ul Flow Cell. K (more)eeps original packaging. The FLD provides quantitative data and fluorescence spectra from a single run. Simultaneous detection of multiple wavelengths improves sensitivity and selectivity. Features include: Rotating gratings for on-line, multi-signal spectral data acquisition without loss of sensitivity. Lower limits of detection with Raman S/N > 3000 (using dark signal noise reference). Spectra and quantitative data from a single run. Simplified optical design to optimize baseline stability. Resolution gain of up to 100% in fast LC using 145 Hz data acquisition rate. Long life xenon lamp for maximum sensitivity. Long life flash lamp (> 4000 hours). Easy front access allows quick inspection or change of the flow cell. Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Lower detection limits and easier spectral analysis for HPLC and UHPLC. As a stand-alone detector or configured in an automated system, the Agilent 1260 Infinity Spectra Fluorescence Detector brings highly sensitive fluorescence detection to your lab. This easy-to-use detector provides quantitative data and fluorescence spectra from a single signal. Simultaneous multiple wavelength detection improves sensitivity and selectivity. Use online spectral information for rapid method optimization and separation quality verification. High-speed fluorescence detection data processing up to 145Hz, keeping pace with ultra-fast LC analysis speed.

€8,750.00 ex VAT
Spain
optical detectors
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]