Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
LabMakelaar Benelux B.V.
Location
Zevenhuizen - Netherlands
Price
€19,999.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

= FOR € 19,999, =

LabMakelaar Benelux B.V.€19,999.00 (ex VAT)
item image

Description by the supplier

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
SCANDITRONIX WELLHOFER Darklight Duo Sensitometer Densitometer X-Ray Constancy-cover
SCANDITRONIX WELLHOFER Darklight Duo Sensitometer Densitometer X-Ray Constancy

one dual function SENSITOMETER and DENSITOMETERManuf: IBA- Scanditronix / Wellhöfer Model: darklight (more) duo Description:combined dual function instrument for the constancy tests in X-Ray film processing or other similar applicationsmicroprocessor - controlled with digital display of all parameters and memory for processes power supply...................4 AA - Alkaline Batteriesor  with included Special  Power Supply for input 230 VAC Mains SPECIFICATIONS SENSITOMETERcolour....................................................................blue --- green selectablepeak wavelength................................................blue = 460 nm........green = 510 nm ..... both ( +/- 10 nm )light exposition.................................................. in 5 steps selectable ( separate for each colour )reproduce accuracy.......................................... +/- 0.02 log exposurelong time stability................................................ +/- 0.02 log exposurecalibration............................................................. +/- 0.04 log exposuregrayscale.............................................................. 21 - steps ..............0.15 log light exposureaccuracy of steps................................................ 0.05 %homogenity........................................................... +/- 0.01 log exposure SPECIFICATIONS DENSITOMETERvisual optical density.......................................... followg. DIN 4512 / ANSI PH 2.19 - 1976.........internal light sourcefocus opening......................................................  3 mmmeasuring range.................................................  from  D = 0 to D = 5.0accuracy and reproduceability......................... 0.02 D instrument is in unused excellent cosmetic condition and 100 % functional testedcomes  D = 2.90 ( nominal )  Standard Calibration Filmcomes with german manual

€400.00 ex VAT
€476.00 incl. VAT if applicable
Germany
general laboratory equipment other
People are watching right now:
Perkin Elmer Model 343 S Polarimeter-cover
Perkin Elmer Model 343 S Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeters, polarimeter
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]