Categories

Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C)

Marshall Scientific$12,170.00 (ex VAT)
item image

Description by the supplier

Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C)



Refrigerant

R-404A

Temperature Range

-20° to 40°C

Cooling Capacity

5000W @ 20°C



Features

- High capacity cooling for lasers, electron microscopes, and other laboratory applications

- Small footprint conserves floor space

- Displays temperature and pressure or flow rate simultaneously

- User-adjustable temperature, pressure, and flow rate alarms

- Simple operation and low maintenance






DuraChill Chillers offer powerful cooling for demanding applications and serve as a cost-effective alternative to tap water cooling systems. Equipped with a microprocessor-based controller, these chillers provide a digital temperature display (in °C or °F), one-touch set point display, and a digital pressure/flow rate display (in PSI, kPa, GPM, LPM) with easy push-button selection. The inclusion of a modulated refrigeration system enhances cooling efficiency and performance, resulting in improved temperature stability and extended compressor life.


With its high-capacity cooling capability, the 3860T56A1C0D is ideal for applications involving lasers, electron microscopes, and other laboratory equipment. The system features dual displays, allowing users to conveniently monitor temperature and process pressure or flow rate simultaneously. User-adjustable alarms for temperature, pressure, and flow rate enable precise control and monitoring. Despite its powerful performance, the chiller has a small footprint that conserves floor space and facilitates seamless integration into laboratory setups.INCLUDED:

The Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C) includes:

- Power Cord

- Operator's Manual

- Manufacturer's Documentation

- 2 Year Manufacturer's Warranty

Product details
Part Number3860T56A1C0D
Working Temperature:-20° to 40°C
Temperature Stability:±0.5°C
Power Requirements:230V, 60Hz, 1 phase, 23.1 A
Reservoir Capacity (gallons/liters):3.5 (13.25)
Overall dimensions (L x W x H):30.5 x 19 x 26” (78 x 48 x 66 cm)
Pump type:3/4HP Turbine Pump
Refrigerant type:R-404A
Process Connections:1/2” female NPT
Cooling Capacity:5000W @ 20°C3000W @ 0°C1500W @ -15°C
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V-cover
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V

Polyscience CA02A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VACFe (more)atures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA02A1P1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA02A1T1-41AA1NCooling Capacity @ 20°C0.85 kWCooling Capacity @ 10°C0.6 kWCooling Capacity @ 0°C0.4 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range20 to 90 psi / 138 to 689 kPaMaximum Pump Flow Rate3.5 gpm / 13.2 lpmPower Requirements120V, 60Hz, 13.7AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(3) { background-color: #fffacd; }

$6,982.00 ex VAT
United States
chillers, heating & cooling
Polyscience BA06A1G3-110A1NC DuraChill Benchtop Chiller, -20C to 30C, 900W, 120V-cover
Polyscience BA06A1G3-110A1NC DuraChill Benchtop Chiller, -20C to 30C, 900W, 120V

Polyscience BA06A1G3-110A1NC DuraChill Benchtop Chiller, -20C to 30C, 900W, 120V Flow Rate 15L/min  (more)(4 gpm) Temperature Range -20C to 30C Cooling Capacity 900W at 20C Features - Intuitive touchscreen display with 5 operating languages (Chinese, English, French, German, Spanish) - Full text messages and audible alarms - Continuous fluid level monitoring to prevent premature pump failure - Variable Fan Speed Technology for quieter operation - UV Light Biological Growth Inhibitor - Patented Self-diagnostic system - Low flow shutoff and alarm, high and low temperature alarms - Displayable temperature units in C or F - RS232, Dry Contact On/Off/Status; optional USB-B and Remote Probe port The Polyscience BA06A1G3-110A1NC DuraChill Benchtop Chiller offers advanced cooling technology with a temperature range of -20C to 30C and a cooling capacity that varies from 150W at -20C to 900W at 20C. It features a microprocessor-based temperature controller with a high-resolution TFT LCD display, enabling temperature readouts in °C or °F and pressure display with an accuracy of ± 35% of full scale. The user-friendly interface includes a touch screen display, a multi-language interface, and touch keypad for precise temperature set-point adjustments. The chiller utilizes a Cool Command modulated refrigeration system to enhance temperature stability and extend compressor life, while the WhisperCool Environmental Control System optimizes noise reduction and energy efficiency. It comes equipped with a centrifugal (magnetic drive) pump capable of delivering a flow rate of 15L/min at 0 psi, with pressure up to 18 psi. Additional features include continuous level sensing in the standard reservoir (1.5L capacity) for pump protection, and an optional UV Anti-Growth Light to prevent biological growth in the process fluid. This makes the DuraChill Chiller a robust and efficient solution for demanding applications where tap water cooling systems fall short. Click Here to View Product Video INCLUDED: The Polyscience BA06A1G3-110A1NC DuraChill Benchtop Chiller, -20C to 30C, 900W, 120V includes: - 1 Pair of 1/2" NPT x 3/8" Barbed Fittings - 1 Pair of 1/2" NPT x 1/2" Barbed Fittings - Power Cord - Operator's Manual - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$6,125.00 ex VAT
United States
chillers, heating & cooling
People are watching right now:
Radwag MA 110.X7.IC.A Moisture Analyzer-cover
Radwag MA 110.X7.IC.A Moisture Analyzer

MA X7.IC.A moisture analyzers are hi-tech measuring instruments intended for quick determination of  (more)relative moisture content, dry mass content and other parameters in samples of different substances. MA.X7.IC.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X7.IC.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X7 Series moisture analyzers: Automatic opening and closing of the drying chamber 7” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X7.IC.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X7 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€2,098.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 50/1.5Y.IC.WH Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]