Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Lauda
Location
Caerphilly - United Kingdom
Price
£1,280.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Lauda Alpha Model RA 8 Chilling Thermostatic Water Bath

£1,280.00 (ex VAT)
item image

Description from the supplier

Lauda Alpha RA 8 Cooling Thermostatic Water Bath
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. (Digital thermometer used for testing not included).
It is in good cosmetic condition with minor marks.

Product details

Electrical SupplyN/A
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Julabo PURA 30 Water Bath, 115V/60Hz (NRTL Certified)-cover
Julabo PURA 30 Water Bath, 115V/60Hz (NRTL Certified)

Julabo PURA 30 Water Bath, 115V/60Hz (NRTL Certified) Working Temperature Range 18°C to 99°C Heatin (more)g Capacity 1300W Volume 36L Features - Ease of use - Bright display - Splash-proof protected mains switch - Built-in dry running protection - No disturbing elements in the bath - Platform included as standard - Integrated timer - Non-slip rubber feet - Ergonomic recessed grips - Integrated drain screw The Julabo PURA water baths stand for a straightforward and safe working in the laboratory. The high-quality water baths offer a temperature stability of ± 0.15°C (with bath cover). The working temperature range of +18°C to 99.9°C (with counter-cooling/bath cover) allows a wide range of applications, such as routine laboratory work, temperature applications for samples, incubation, material testing, corrosion testing, temperature control applications of cultures as well as temperature tests of food and beverages and in the dental field. All models (except PURA 4) come with an integrated drain screw for quick and clean draining of the baths. PURA water baths can be used flexibly and can be easily transported through ergonomic side recessed grips. Non-slip rubber feet ensure a firm footing and more safety in the laboratory. The units are splash-proof, feature a (membrane) keypad and temperature display (LED) for ease of use. Operation in °F or °C with integrated timer. There are no disturbing parts inside the bath so that the entire inner surface can be used to safely temperature-control even small sample containers. Click Here to View Product Video INCLUDED: The Julabo PURA 30 Water Bath, 115V/60Hz (NRTL Certified) includes: - Platform - Power Cord - Operator's Manual - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$2,565.00 ex VAT
United States
baths or circulators
People are watching right now:
Memmert IPP55 Peltier-Cooled Forced Circulation Incubator 53L, 115V-cover
Memmert IPP55 Peltier-Cooled Forced Circulation Incubator 53L, 115V

Memmert IPP55 Peltier-Cooled Forced Circulation Incubator 53L, 115V Setting Temperature Range Ambie (more)nt 0°C to 70°C Convection Type Peltier Fan Forced Circulation Chamber Volume 53 L (1.9 cu.ft.) Features - 53 L volume capacity for flexible storage and temperature control - Setting temperature range from 0°C to +70°C with 0.1°C accuracy - Energy-saving Peltier heating/cooling system integrated in the rear - ControlCOCKPIT with adaptive multifunctional PID-microprocessor controller and high-definition TFT-color display - Process time starts only when the set temperature is reached with the SetpointWAIT function - Three freely selectable temperature calibration values for precise control - Adjustable electronic overtemperature monitor and mechanical temperature limiter for safety - Durable, corrosion-resistant stainless steel interior and textured stainless steel exterior The Memmert IPP55 Peltier-Cooled Forced Circulation Incubator 53L, 115V offers precise temperature control with an energy-efficient Peltier heating and cooling system. Designed for laboratory environments, this incubator features a setting temperature range from 0°C to +70°C and an accuracy of 0.1°C, ensuring consistent results across a variety of applications. The ControlCOCKPIT adaptive multifunctional PID-microprocessor controller with a high-definition TFT-color display provides intuitive control, while the SetpointWAIT function ensures that processes only begin once the desired temperature is reached. Built with a 53-liter stainless steel interior, this incubator is both robust and easy to clean, making it ideal for long-term use. It supports up to four shelves with a maximum chamber load of 176 lbs, providing ample space for different sample sizes. Safety is a priority with an adjustable electronic overtemperature monitor, mechanical temperature limiter, and an autodiagnostic system for fault analysis. With its durable textured stainless steel exterior, the IPP55 is built to withstand the rigors of daily laboratory use while maintaining high performance and reliability. INCLUDED: The Memmert IPP55 Peltier-Cooled Forced Circulation Incubator 53L, 115V includes: - 1 Stainless Steel Grid - Tilt Protection Wall Bracket - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$5,398.00 ex VAT
United States
incubators
Radwag HX5.EX-1.15.F1 One Load Cell Platform Scale-cover
Radwag HX5.EX-1.15.F1 One Load Cell Platform Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€2,870.00 ex VAT
Poland
platform scales, scales for ex areas
Radwag MA 110.5Y.IC Moisture Analyzer-cover
Radwag MA 110.5Y.IC Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,940.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]