Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
JASCO
Model
JASCO UV-2075 Plus
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€1,500.00 
(€1,785.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 31,00 kg

Categories

Jasco UV-2075 Plus HPLC Intelligent UV/Vis Detector Detektor UV-2075 VWD

PROFCONTROL GmbH€1,500.00 
(€1,785.00 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Mixed Job Lot of Laboratory Equipment - IKA, Stuart, Metrohm, Kroy, Elga etc
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Mixed Job Lot of Laboratory Equipment - IKA, Stuart, Metrohm, Kroy, Elga etc NOTE - THIS IS A SPARES/REPAIRS ITEM

This job lot of items comes from a variety of university laboratories. The items were no longer requ (more)ired, collected from various store rooms and facilities. None of these items have been tested at our site - it is likely that some will be spares / repairs, but we anticipate that a reasonable amount should operate well. None of these items have been PAT or electrical safety tested. For this reason we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks. They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the unit. It is an excellent opportunity for anyone looking to benefit for individual equipment resale. The units have not been tested at all. ITEM-34625 Lot of Hanna Instruments pH Meters ITEM-41847 Metrohm 830 IC interface ITEM-41848 Metrohm 833 IC Liquid Handing Unit ITEM-41849 Metrohm 818 IC Pump ITEM-38036 Thermo Px2 Thermal Cycler With Thermo Hybaid PCR Express Lab ITEM-41914 HP 107a Laser PrinterITEM-41915 Lot of Three Of Cole-Parmer SHM-200 Heating MantlesITEM-41916 IKA MSC Basic C Heated Stirring PlateITEM-41917 Kroy K3110-PC Thermal Printer ITEM-41920 Pair of Thurlby 1503-HA Digital MultimetersITEM-41921 Lot of 3 Advanced Instruments DMM2 Digital MultimetersITEM-41922 Gould Advance DMM7A Digital Multimeter ITEM-41923 Philips PW9526 Digital Conductivity Meter ITEM-41924 Griffin Magnetic Stirrer ITEM-41925 Electrothermal M105 Heating Mantle ITEM-41926 Pair of Electrothermal M103 Heating MantlesITEM-41927 Pair of Electrothermal ML02 Heating MantlesITEM-41928 Reeve Computer Interface Control Box With Marconi RB2 Tracker Ball ITEM-41929 Tekman TE 200 Graph Printer Plotter ITEM-41930 Stuart 6M4 Magnetic StirrerITEM-41931 Pair of Griffin and George Galvanometers ITEM-41932 Reeve 9701 Radio Activity Monitor ITEM-41933 Pair of Bellingham and Stanley Polarimeters ITEM-41934 Meta Therm HPLC Column Control ITEM-41935 Elga Purelab Option Water Purifier Model OR007BPM1ITEM-41936 Pair of Buchi B-169 Vacuum Systems ITEM-41945 Four Position Ammeter Control Box With two RS Ammeters ITEM-41947 Lot of 4 Nuclear Enterprises SR7 Scaler Ratemeters ITEM-41948 Goerz Electro Potentiometer Schreiber Servoscribe Type RE 511ITEM-41949 Camag Universal UV Lamp Type TL-900 ITEM-41950 Lot of 11 NE Technology ST7 Scaler Timers ITEM-41955 Metcalf Brothers Hyflow Air Pump Model C ITEM-41956 Bellingham and Stanley Refractometer ITEM-41957 Thermo Separation Products Spectra Series UV Single Wavelength Detector ITEM-41958 Brooks 5850E Mass Flow ControllerITEM-41959 Hewlett-Packard Model 17422B 10v Power AdapterITEM-41961 Advance Instruments DMM2 Digital MultimeterITEM-41962 Stuart SMP11 Melting Point Apperatus ITEM-41963 Pair of Fluke 8050A Digital Multimeters

£500.00 ex VAT
United Kingdom
hplc equipment other, general laboratory equipment other
Mixed Job Lot of Laboratory Equipment , Perkin Elmer, Agilent, Siemens, Mettler
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Mixed Job Lot of Laboratory Equipment , Perkin Elmer, Agilent, Siemens, Mettler NOTE - THIS IS A SPARES/REPAIRS ITEM

This job lot of items comes from a variety of university laboratories. The items were no longer requ (more)ired, collected from various store rooms and facilities. None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well. None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks. They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale. The units have not been tested at all. ITEM-38571 Mettler GA44 Printer ITEM-38340 Agilent 1200 Series HPLC 2303TX Valve Interface ITEM-38341 Agilent 1200 Series HLPC 2303TX Valve Interface ITEM-38572 Siemens Clinitek 500 Urine Sampler ITEM-38573 Unitek HS-001 Hotplate ITEM-38574 Genetix GelPal [condition: Used]ITEM-38575 Perkin Elmer Radiomatic 625TR Accessories/Spare Parts ITEM-38578 Perkin Elmer Radiomatic 625TR ITEM-38577 Perkin Elmer Radiomatic 625TR ITEM-38576 Perkin Elmer Radiomatic 625TR ITEM-38579 DIONEX ICS-3000 ITEM-37660 Hewlett Packard 5972 Series MSDITEM-37661 2 x Agilent G1323B Controller ITEM-37662 2 x Fisherbrand Mini Vortex Mixer ITEM-38582 Dionex ICS-3000 DC Detector Module ITEM-38586 Dionex AXP-MS Auxiliary Pump ITEM-37669 Edwards Outlet Mist Filter MF20 ITEM-38585 Dionex AS-1 Autosampler ITEM-37668 2 x ZHCR Vacuum Pump 9000-1130/1471 ITEM-37665 Molecular Devices ThermoMax Microplate Reader ITEM-37664 Microlab 500 Series ITEM-37663 Jones Chromatography Model 7990ITEM-37674 2 x Black Box Pow-R-Switch IS ITEM-37676 Black Box Pow-R-Switch IM ITEM-37705 Jones Chromatography Electronic Valve Actuator EVA ITEM-37706 NetQue Printer Server Model NQ02 ITEM-37707 Pair of Packard Bioscience Nalgene 6 litre Jerricans with Level Sensors ITEM-37680 Zebra 105SL Thermal Barcode Label Printer ITEM-37679 Jones Chromatography Column ChillerITEM-37715 Three Matrix Foot Pedal Switches ITEM-37716 UVP UVLS-28 Ultra Violet Light with Stand ITEM-37698 Mettler Me-210270 ITEM-37718 Philips Linhof Super Rollex Roll Film Holder ITEM-37697 Janke & Kunkel RW-20 StirrerITEM-37696 RT Power Supply Spot

£500.00 ex VAT
United Kingdom
general laboratory equipment other, hplc equipment other
Job Lot of Mixed Laboratory Equipment - Sartorius, IKA, Bruker Lab
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Job Lot of Mixed Laboratory Equipment - Sartorius, IKA, Bruker Lab NOTE - THIS IS A SPARES/REPAIRS ITEM

This job lot of items comes from a variety of university laboratories. The items were no longer requ (more)ired, collected from various store rooms and facilities. None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well. None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks. They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale. The units have not been tested at all. ITEM-39808 MSE Centaur 2ITEM-39805 Sorval TC6 ITEM-39837 Sartorius BP 11 ITEM-35985 Micromeritics sedigraph 5100 ITEM-35986 Ibm personal system 2 model 30 [condition: Used]ITEM-35987 Epson FX-850 [condition: Used]ITEM-35990 IBM Personal system 2 monochrome display [condition: Used]ITEM-35991 Techne Genius [condition: Used]ITEM-38936 Howe GyroVap [condition: Used]ITEM-36540 Sartorius Startoclear Depth Filter Maxicaps [condition: Used]ITEM-39844 MJ Research DNA Engine Tetrad 2 PTC Peltier Thermal Cycler Lab [condition: Used]ITEM-38938 Heraeus Rotor & Buckets [condition: Used]ITEM-38939 3Com baseline Switch 2816 [condition: Used]ITEM-37437 Cryofusion Liquid CO2 Back up system [condition: Used]ITEM-37441 UVP UV/White Convertor Plate [condition: Used]ITEM-36544 IKA Vibrax VXR [condition: Used]ITEM-36552 Bruker BSPS 12 80 2 WS1212316ITEM-36554 Philips CD650 CD player [condition: Used]ITEM-36005 Invitrogen E-Gel iBase Safe Imager + iBase [condition: Used]ITEM-18758 BOC Edwards Speedivalve SP25K N 9Bar Fluoroelastomer Diaphragm Valve Lab [condition: New]ITEM-36008 Milli-Q Q pod [condition: Used]ITEM-39860 Capp CR-MI1 ITEM-39861 Ohaus Pioneer pa2102cm ITEM-39865 Bio Rad Benchmark PlusITEM-39866 Grant FH16-D ITEM-39867 Gilson 305 Pump ITEM-39868 Sartorius BP 3100S ITEM-39869 Sartorius 1212 MP ITEM-39870 Restek Electronic Flow Calibrator ITEM-36014 Box of Thermo Fisher HPLC Parts [condition: Used]ITEM-36015 Security guard hplc guard cartridge system [condition: Used]ITEM-36016 Lot of PCR equipment [condition: Used]ITEM-36017 2 x GelBond PAG Film [condition: Used]

£500.00 ex VAT
United Kingdom
general laboratory equipment other, hplc equipment other
People are watching right now:
MARSHALL Select MS-PA10UL Autoclavable Pipette, 0.5-10ul-cover
MARSHALL Select MS-PA10UL Autoclavable Pipette, 0.5-10ul

MARSHALL Select MS-PA10UL Autoclavable Pipette, 0.5-10ul Volume Range 0.5 to 10ul Adjustable or Fix (more)ed Volume Adjustable Pipette Type Manual Air Displacement Features - Ergonomic design with a light touch plunger and relaxed finger rest reduces user fatigue - Fully autoclavable, allowing for easy sterilization - Constructed from high-quality, heat-resistant materials for durability - UV and chemical resistant to withstand harsh laboratory conditions - Centrally located digital display facilitates ambidextrous use - Quick-release pipette tip ejector simplifies tip changes - Volume lock prevents accidental volume adjustments - Compatible with universal pipette tips for versatility - Suitable for both forward and reverse pipetting techniques - Ideal for handling both low and high-viscosity liquids, enhancing versatility in laboratory procedures The MARSHALL Select MS-PA10UL Autoclavable Pipette is a high-performance, manual air displacement pipette designed for precision and comfort in laboratory applications. This pipette offers an adjustable volume range from 0.5 to 10ul with precise 0.1ul increments, ensuring accurate measurements. It features an ergonomic design with a light touch plunger and relaxed finger rest, which minimizes user fatigue and enhances comfort during extended use. Constructed from high-quality, heat-resistant materials, the MS-PA10UL is fully autoclavable, providing excellent protection against UV light and chemicals, ensuring durability and reliability in harsh laboratory environments. The design includes a centrally located digital display for easy viewing by both left- and right-handed users, enhancing its ambidextrous usability. Additional features include a rotating counter knob for quick volume setting, a quick-release pipette tip ejector for convenient tip changes, and a volume lock to prevent accidental adjustments. This pipette is compatible with universal pipette tips and is suitable for both forward and reverse pipetting techniques, making it versatile for handling low-viscosity liquids as well as more challenging higher-viscosity or foamy samples. The MS-PA10UL is the ideal choice for laboratories seeking a reliable, easy-to-use pipette that meets rigorous standards, including ISO 9001:2008 and ISO 13485:2003 certifications, along with CE marking. INCLUDED: The MARSHALL Select MS-PA10UL Autoclavable Pipette, 0.5-10ul includes: - Operator's Manual - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$151.00 ex VAT
United States
pipettes, autoclaves or sterilizers
Memmert WTB50 Digital Water Bath 51L, 115V-cover
Memmert WTB50 Digital Water Bath 51L, 115V

Memmert WTB50 Digital Water Bath 51L, 115V Volume 51 L Working Temperature Range +5 above ambient t (more)o +100 °C Setting Accuracy 0.1°C Features - Precise temperature control with a working range from 5°C above ambient up to +100°C ensures consistent results - Highly accurate settings with 0.1°C precision for optimal temperature management - spacious 51-liter capacity designed to handle a wide range of applications - Durable, corrosion-resistant stainless steel construction guarantees long-lasting performance - Effortless operation with an intuitive 3.5" color touch screen for quick adjustments - Advanced two-stage safety system prevents overtemperature, protecting your valuable samples - Autodiagnostic system with built-in fault detection keeps your process running smoothly - Easy-to-clean deep-drawn stainless steel tray with central drain minimizes maintenance time The Memmert WTB50 Digital Water Bath 51L, 115V offers precise temperature control with a working range from 5°C above ambient up to +100°C, ensuring accurate and reliable performance across various applications. Its spacious 51-liter capacity makes it ideal for larger tasks, while its stainless steel construction ensures durability and corrosion resistance. With a setting accuracy of 0.1°C, users can confidently manage temperature-sensitive processes. The water bath's 3.5" color touch screen provides intuitive operation, allowing for quick adjustments to maintain optimal conditions. For added safety, the Memmert WTB50 features a two-stage overtemperature protection system, including a pressure sensor for level monitoring and a thermal fuse for automatic heating shutdown in case of an error. The built-in autodiagnostic system with fault detection keeps processes running smoothly. Maintenance is simple, thanks to the easy-to-clean deep-drawn stainless steel tray with a central drain. Additionally, a digital timer and independent temperature limiter further enhance control and operational safety. INCLUDED: The Memmert WTB50 Digital Water Bath 51L, 115V includes: - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$2,397.00 ex VAT
United States
baths or circulators
Bruker LC-NMR-MS Interface-cover
Bruker LC-NMR-MS Interface

The LC-NMR-MS Interface is designed to sit between an HPLC system, an NMR spectroscopy probehead and (more) an MS unit. It would normally be mounted on top of the MS table immediately in front of the MS input connector. The BNMI-HP consists of 3 medium pressure (> 60Bar) syringe pumps, a 1:20 splitter, an 8-Port valve, 3 mixing chambers (T-Pieces) and associated control and interface electronics. The flow of the HPLC separations to the MS unit can be modified by pumping additional solvent from the syringe pumps. This improves the MS peak detection and shortens the time needed for the split separation to reach the MS. Separations can also be stored as a result of an MS peak detection as well as through UV absorption peak detection. The splitter splits the fluid flow from the HPLC in a 1:20 ratio. i.e. ca. 5% of the fluid is directed to the MS and the remainder to either the NMR probehead for immediate analysis or to the BPSU36 storage cassette for storage and later analysis.  The fluid directed to the MS is mixed in the mixing chamber (T-Piece) with the solvent pumped from the syringe pumps. The two left hand syringe pumps pump alternatively to guarantee a constant ’makeup’ flow. The 3rd pump at the right hand side is used to pump a calibration fluid into the flow path to allow the MS to be calibrated (or simply synchronized) at the start and end of each measurement cycle. The 8-Port valve is used to direct the fluid flow. Control of the BNMI Unit is performed using the HyStar program via an ethernet interface. Commands received from HyStar are interpreted in the BNMI Control Board. The control board then sets up the BNMI unit accordingly e.g.: Starts the pumps, changes the flow rate, turns the 8-Port valve. The splitter has a fixed mechanical function and cannot be controlled or adjusted. It simply accepts a fluid flow and splits it into 2 paths in a 1:20 ratio. However, other split ratios are available (for example 1:100 may be preferred if you have very high sample concentrations).

€1,499.00 ex VAT
Netherlands
nmr spectrometers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]