Viscotek TDA 302 Triple Detector Detektor Array GPC SEC RID ELSD UV-2501 UV 2501
Manufacturer: Viscotek Model: TDA 302 Triple Detector Detektor Array + 2501 UV Detector S/N (TDA 302 (more) Triple Detector Detektor Array): 302-0604-190 S/N (2501 UV Detector): 76363 Description: The Model 302 TDA Differential Refractometer is the basic detector component of a system for polymer analysis by gel permeation chromatography (GPC), also called size exclusion chromatography (SEC). SEC involves separation through the hydrodynamic volume of the molecular distribution. The refractometer can also be used to determine the concentration of solutions after calibration. It is specifically designed for polymer analysis by SEC3 or FIPA.In an SEC3 system, the Deflection-type refractometers are the most common type used in SEC separation; they operate by measuring the deflection of a light source caused by a difference in the refractive index of a sample-solvent mixture and pure solvent. Because different polymer types have different differential refractive index responses with concentration (dn/dc), each polymer type must have a unique RI response factor. Therefore, the area of the RI is proportional to the product of the concentration, injection volume and inverse flowrate of the sample only across a single sample type. The RI area is exactly proportional to the quantity of the mass injected of the sample and its dn/dc value. The Model 302 TDA is designed to be directly to the outlet of a properly functioning HPLC pump by the minimum length possible of 0.01”id SS tubing. The viscometer detector utilizes the patented technology of the four-capillary bridge to minimize the influence of flow rate fluctuations and maximize the sensitivity of detection. Accurate measurement of the polymer or protein concentration profile is essential to good molecular weight or structure data. The high-stability Viscotek UV-PDA 2501 is ideally suited for multi-detection GPC/SEC. The Viscotek UV-PDA is sold as an addition to the Viscotek TDAmax to complete a Tetra Detector format, or as a stand-alone module for connection to other chromatography components, such as the 270max system. Excellent tool for the compositional analysis of co-polymers or protein conjugates. UV-PDA allows the mapping of the molecular weight to the full UV spectrum. Precise and accurate temperature control as the detector cell is housed in the same thermal chamber as the rest of the system. Unmatched baseline stability and data reproducibility. Also available is a single wavelength detector. Specifications: Light Scattering Detector:- Measuring Angle: 90° and 7°- Light Source: Constant optical power output laser diode- Wavelength: 670 nm- Output Power: 3 mW- Detectors: Photodiode/Amplifier- Cell Volume: 10 µL Viscometer:- Dimensions: 0.01”id x 24”L- Bridge Balance: 1 %- Maximum Flow Rate (H2O): 1.5 mL/min- Maximum Flow Rate (THF): 3 mL/min- DP Noise Maximum: 0.3 mV (0.3Pa)- DP Noise Typical: 0.2 mV (0.2Pa)- DP Drift Typical: 1.5 mV/hrRefractometer detector / RI:- Cell volume: 12 µL- Maximum backpressure on cell: 30 kPa- Maximum Signal (nom.): 10 V (nom.)- Baseline Noise: 0.10 mV- Baseline Noise (RIU)15 2 x 10-8- Baseline Drift: 16 5.0 mV/hr Items delivered: - Viscotek TDA 302 Triple Detector Array- Viscotek 2501 UV Detector- Connecting cables Condition: The entire system is in very good cosmetic as well as tecnical condition. It is 100% functional tested and ready to be operated. Buy with confidence!
€6,500.00 ex VAT
€7,735.00 incl. VAT if applicable
Germany
hplc accessories, gpc systems